Table Drafts 5

Jump to: navigation, search

Table Drafts 5

Revision as of 15:16, 3 December 2024 by James Klassen (talk | contribs)

Division C - Accepted Materials


Vegetated ("Green") Roof Systems (VRS)

Vegetated Roof Systems
Click on a manufacturer's name to see the full list of their vegetated roof systems accepted for use in the RoofStar Guarantee Program. Click on the System Name to see the materials and documentation for the system.
To reset this page to its original view, click your browser refresh button.
VRS Supplier VR System Name * VRS
Type
Permissible
Roof Assembly
System
Min.
Depth
mm (in)
System
Max.
Depth
mm (in)
Media
Min.
Depth
mm (in)
Media
Max.
Depth
mm (in)
Carlisle SynTec Systems Canada Carlisle Extensive Roof Garden System Extensive All 101.6 (4) 127 (5) 70 (1-1/4) 127 (5)
Carlisle SynTec Systems Canada Carlisle Roof Garden Extensive Stormwater Retention System Extensive All 140 (5-1/2) 140 (5-1/2) 101.6 (4) 101.6 (4)
Carlisle SynTec Systems Canada Carlisle Semi-Intensive Roof Garden System Semi-Intensive PMRA** 158.8 (6-1/4) 235 (9-1/4) 127 (5) 203.2 (8)
Carlisle SynTec Systems Canada Carlisle Intensive Roof Garden System Intensive PMRA** 235 (9-1/4) None Stated 203.2 (8) None Stated
Hydrotech Membrane Corporation Hydrotech Extensive Garden Roof Assembly Extensive All 101.6 (4) 203.2 (7) 76.2 (3) 152.4 (6)
Hydrotech Membrane Corporation Hydrotech Semi-intensive Garden Roof Assembly Semi-Intensive PMRA** 203.2 (8) 355.6 (14) 152.4 (6) 304.8 (12)
Hydrotech Membrane Corporation Hydrotech Intensive Garden Roof Assembly Intensive PMRA** 355.6 (14) 939.8 (37) 304.8 (12) 889 (35)
Next Level Stormwater Management NLSM LiteN'Less Extensive All 40.7 (1-5/8) 64.0 (2-1/2) 25.4 (1) 25.4 (1)
Next Level Stormwater Management NLSM LiteN'Less II Extensive All 30.7 (1-1/8) 30.7 (1-1/8) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM LiteN'Less III Extensive All 45.0 (1-13/16) 62.0 (2-7/16) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM TerraEXT Extensive All 113.0 (4-13/16) 188 (7-13/16) 95.0 (3-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Extensive All 114 (4-1/2) 264 (10-3/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Detain 3° Extensive All 114 (4-1/2) 352 (13-7/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM Eco-Grass Semi-Intensive PMRA** 188 (7-7/16) 338 (13-5/16) 170 (6-11/16) 320 (12-9/16)
Next Level Stormwater Management NLSM Flora Garden Semi-Intensive PMRA** 162 (6-3/8) 312 (12-5/16) 150.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Extensive-Conv. Veg. Roof Extensive All 85.85 (3-3/8) 162 (6-3/8) 76.2 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Extensive-Inverted Veg. Roof Extensive All 88.1 (3-6/16) 164.3 (6-6/16) 76.3 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Modular-Conv. Veg. Roof Extensive All 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Modular-Inverted Veg. Roof Extensive All 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Semi-Intensive-Inverted Veg. Roof Semi-intensive PMRA** 164.3 (6-6/16) 316.7 (12-6/16) 152.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Intensive-Inverted Veg. Roof Intensive PMRA** 361.7 (12-6/16) 361.7 (12-6/16) + 304.8 (12) 304.8 (12) +
Soprema Inc. SKYWATER® Ballasted-Conv. Hybrid Roof Hybrid PMRA** 107.9 (4-1/4) 336.5 (13-1/4) + 76.3 (3) 304.8 (12) +
Soprema Inc. SKYWATER® Ballasted-Inverted Hybrid Roof Hybrid PMRA** 107.9 (4-1/4) 336.5 (13-1/4) + 76.3 (3) 304.8 (12) +
Soprema Inc. SKYWATER® SOPRAFLOW CONTROL Hybrid PMRA** 136.9 (5-3/8) 265.2 (14-3/8) 76.3 (3) 304.8 (12) +
ZinCo Canada Inc. ZinCo Sedum Roof Extensive All 101.6 (4) 127 (5) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof (Inverted) Extensive All 101.6 (4) 127 (5) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof XL Extensive All 114.3 (4-1/2) 152.4 mm (6) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof XL (Inverted) Extensive All 114.3 (4-1/2) 152.4 mm (6) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) Semi-intensive PMRA** 185 (7-1/4) 203.2 (8) 152.4 (6) 152.4 (6)
ZinCo Canada Inc. ZinCo Roof Garden Assembly (Inverted) Intensive PMRA** 241.3 (9-1/2) 260.35 (10-1/4) 203.1 (8) 203.1 (8)
ZinCo Canada Inc. ZinCo Blue Roof Assembly (Inverted) Intensive PMRA** 215.9 (8-1/2) 304.8 (12) 101.6 (10) 304.8 (12)
ZinCo Canada Inc. ZinCo Green Roof & Solar Extensive All 203.2 (8) 203.2 (8) 101.6 (4) 101.6 (4)
ZinCo Canada Inc. ZinCo Green Roof & Solar (Inverted) Extensive PMRA** 203.2 (8) 203.2 (8) 101.6 (4) 101.6 (4)
* Click on the Vegetated Roof Name to link to the system page for specified or optional vegetation profiles
** While Semi-intensive, Intensive, and Hybrid (blue-green) vegetated roof systems are permitted only on protected membrane roofs (also called "inverted roof assemblies"; see the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs (these systems are accepted by the RGC and listed here but are non-conforming to the RGC Standard). Consult the system manufacturer for a re-design of the system for use on a protected membrane roof, or submit a request to the RGC for a written Variance to permit the system on a conventionally insulated roof assembly following the requirements in Article 1.1.3.6..
Vegetated roof systems can be divided into three classic types: Extensive, Semi-intensive, and Intensive. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the Notes to the Standard for Vegetated Roofs for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the system page for more information.