Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Line 16: | Line 16: | ||
(1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing''']] and the Membrane Manufacturer's installation specifications. | (1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing''']] and the Membrane Manufacturer's installation specifications. | ||
− | (2) | + | (2) '''Membrane Primer or Adhesive''': Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications. |
(3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards. | (3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards. | ||
Line 25: | Line 25: | ||
=== WORK BY OTHERS === | === WORK BY OTHERS === | ||
− | (A) | + | (A) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPDECK '''Acceptable Deck''']: Concrete slab depicted. |
− | (B) | + | (B) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Unit Masonry Wearing Coarse''']: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads. |
− | (C) | + | (C) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPLEAK '''Conductive Tape''']: Moisture Survey System (tape grid) <b>mandatory</b> and compliant with RoofStar Guarantee Standards. For RoofStar-accepted Moisture Survey Tape Systems, refer to [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPLEAK '''MEMBRANE MOISTURE SURVEYS & MONITORING SENSOR GRIDS''']. |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 17:07, 12 October 2016
RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing and the Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.
(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab depicted.
(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.
(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RoofStar Guarantee Standards. For RoofStar-accepted Moisture Survey Tape Systems, refer to MEMBRANE MOISTURE SURVEYS & MONITORING SENSOR GRIDS.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application