Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
(→WORK INCLUDED) |
|||
Line 39: | Line 39: | ||
− | + | [[RoofStar Guarantee Standards for Waterproofing|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces]] | |
− | [[ | ||
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']] | [[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']] | ||
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 20:07, 25 October 2016
RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and the Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.
(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab depicted.
(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.
(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RoofStar Guarantee Standards. For RoofStar-accepted Moisture Survey Tape Systems, refer to MEMBRANE MOISTURE SURVEYS & MONITORING SENSOR GRIDS.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.