Difference between revisions of "ASM Eave Protection and Underlayment"

Jump to: navigation, search

Difference between revisions of "ASM Eave Protection and Underlayment"

(RELATED WORK BY OTHERS)
Line 13: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 100 mm (4") minimum end laps.  
+
;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 100 mm (4") minimum end laps.  
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMICE|'''Ice and Water Protection''']]: One ply of accepted self-adhered modified bituminous membrane.  
+
;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMICE|'''Ice and Water Protection''']]: One ply of accepted self-adhered modified bituminous membrane.  
 
;(3) '''Edge Metal Flashing''': Installed to manufacturer's printed instructions.  
 
;(3) '''Edge Metal Flashing''': Installed to manufacturer's printed instructions.  
  
Line 24: Line 24:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->

Revision as of 17:10, 23 October 2017

RoofStar Guarantee Standards are blue-linked
ASM Details

8.1.jpg

1 WORK INCLUDED

(1) Underlayment
Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 100 mm (4") minimum end laps.
(2) Ice and Water Protection
One ply of accepted self-adhered modified bituminous membrane.
(3) Edge Metal Flashing
Installed to manufacturer's printed instructions.
Note:
  • This specification is only applicable to slopes 1:3 (4" in 12") or greater
  • Slip sheet not shown for clarity

2 RELATED WORK BY OTHERS

(A) Acceptable Deck


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.





RoofStar Guarantee Standards for ASM Roof Systems

Back to ASM Construction Details

Back to Construction Details