Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Jump to: navigation, search

Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

(RELATED WORK BY OTHERS)
Line 13: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment and Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.  
+
;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment and Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.  
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEDGE|'''Edge Metal Flashing''']]: Installed to manufacturer's printed instructions.  
+
;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMEDGE|'''Edge Metal Flashing''']]: Installed to manufacturer's printed instructions.  
  
 
:'''Note''': This specification is applicable to slopes 1:6 (2" in 12") and greater.
 
:'''Note''': This specification is applicable to slopes 1:6 (2" in 12") and greater.
Line 21: Line 21:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->

Revision as of 17:11, 23 October 2017

RoofStar Guarantee Standards are blue-linked
ASM Details

8.1.4.2.1.jpg

1 WORK INCLUDED

(1) Underlayment and Eave Protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(2) Edge Metal Flashing
Installed to manufacturer's printed instructions.
Note: This specification is applicable to slopes 1:6 (2" in 12") and greater.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




RoofStar Guarantee Standards for ASM Roof Systems

Back to ASM Construction Details

Back to Construction Details