=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM Roof | + | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. |
− | ;(2) [[RoofStar Guarantee Standards for ASM Roof | + | ;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer. |
− | ;(3) [[RoofStar Guarantee Standards for ASM Roof | + | ;(3) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] |
;(4) '''Flange''': Set in two continuous beads of accepted caulking. | ;(4) '''Flange''': Set in two continuous beads of accepted caulking. | ||
;(5) '''Preformed Penetration Collar''' | ;(5) '''Preformed Penetration Collar''' | ||
− | ;(6) [[RoofStar Guarantee Standards for ASM Roof | + | ;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications. |
;(7) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking. | ;(7) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking. | ||
;(8) '''Stainless Steel Drawband''' | ;(8) '''Stainless Steel Drawband''' | ||
Line 36: | Line 36: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[RoofStar Guarantee Standards for ASM Roof | + | ;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']] |
;(B) '''Location Of Penetrations''': Must not interfere with standing seams or trapezoidal and intermediate ribs. | ;(B) '''Location Of Penetrations''': Must not interfere with standing seams or trapezoidal and intermediate ribs. | ||
;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels. | ;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels. |
Revision as of 17:16, 23 October 2017
RoofStar Guarantee Standards are blue-linked |
ASM Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (3) Architectural Metal Roof Panel
- (4) Flange
- Set in two continuous beads of accepted caulking.
- (5) Preformed Penetration Collar
- (6) High-domed Gasketed Cladding-type Screws
- Flange fastened to manufacturer's specifications.
- (7) Seal Between Pipe And Flashing
- Continuous tooled bead of accepted caulking.
- (8) Stainless Steel Drawband
- (9) Water Tight Back Up Storm Collar
- Installed where practical.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Location Of Penetrations
- Must not interfere with standing seams or trapezoidal and intermediate ribs.
- (C) Opening In Roof Deck
- Must be large enough to allow for thermal movement of metal roof panels.
- (D) Pipe Or Support Stand
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for ASM Roof Systems