Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"
Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"
Line 13: | Line 13: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM Roof | + | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. |
;(2) '''Insulation Overlay Protection''': Recommended. | ;(2) '''Insulation Overlay Protection''': Recommended. | ||
− | ;(3) [[RoofStar Guarantee Standards for ASM Roof | + | ;(3) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination. |
;(4) ''''Z'-Bar''': Installed to meet adequate attachment for UL I-90 wind uplift requirements. | ;(4) ''''Z'-Bar''': Installed to meet adequate attachment for UL I-90 wind uplift requirements. | ||
− | ;(5) [[RoofStar Guarantee Standards for ASM Roof | + | ;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS |'''Insulation''']]: Installed between ‘Z’ bars or wood battens on 600 mm (24") centres. |
− | ;(6) [[RoofStar Guarantee Standards for ASM Roof | + | ;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking. |
− | ;(7) [[RoofStar Guarantee Standards for ASM Roof | + | ;(7) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMEXFASTEN |'''Exposed Fasteners''']]: High domed, gasketed cladding type screws compatible with metal roof panel. |
;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). | ;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). | ||
− | ;(9) [[RoofStar Guarantee Standards for ASM Roof | + | ;(9) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDRAG |'''Drag-load Fasteners''']]: Compatible non-corrosive fasteners. |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[RoofStar Guarantee Standards for ASM Roof | + | ;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 17:23, 23 October 2017
RoofStar Guarantee Standards are blue-linked |
ASM Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Insulation Overlay Protection
- Recommended.
- (3) Architectural Metal Roof Panel
- Turn up (bread panned) at termination.
- (4) 'Z'-Bar
- Installed to meet adequate attachment for UL I-90 wind uplift requirements.
- (5) Insulation
- Installed between ‘Z’ bars or wood battens on 600 mm (24") centres.
- (6) Pre-formed Foam Closures
- Set in accepted caulking.
- (7) Exposed Fasteners
- High domed, gasketed cladding type screws compatible with metal roof panel.
- (8) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").
- (9) Drag-load Fasteners
- Compatible non-corrosive fasteners.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for ASM Roof Systems