=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM Roof | + | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. |
− | ;(2) [[RoofStar Guarantee Standards for ASM Roof | + | ;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer. |
− | ;(7) [[RoofStar Guarantee Standards for ASM Roof | + | ;(7) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners. |
− | ;(4) [[RoofStar Guarantee Standards for ASM Roof | + | ;(4) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions. |
− | ;(5) [[RoofStar Guarantee Standards for ASM Roof | + | ;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMZ |''''Z' Closure''']]: Set in accepted caulking and secured with compatible non-corrosive flat head fasteners. |
;(6) '''Perforated Metal Screen''' | ;(6) '''Perforated Metal Screen''' | ||
;(7) '''Continuous Cleat''' | ;(7) '''Continuous Cleat''' | ||
Line 23: | Line 23: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[RoofStar Guarantee Standards for ASM Roof | + | ;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']] |
;(B) '''Wood Nailer''' | ;(B) '''Wood Nailer''' | ||
;(C) '''Air Space''': Determined by Design Authority. | ;(C) '''Air Space''': Determined by Design Authority. |
Revision as of 17:24, 23 October 2017
RoofStar Guarantee Standards are blue-linked |
ASM Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (7) Architectural Metal Roof Panel
- Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.
- (4) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (5) 'Z' Closure
- Set in accepted caulking and secured with compatible non-corrosive flat head fasteners.
- (6) Perforated Metal Screen
- (7) Continuous Cleat
- (8) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Nailer
- (C) Air Space
- Determined by Design Authority.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.