Difference between revisions of "SBS Fall Protection Anchor in Wall (Protected)"

Jump to: navigation, search

Difference between revisions of "SBS Fall Protection Anchor in Wall (Protected)"

Line 22: Line 22:
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
 
;(A) [[RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies#SBSDECKS|'''Acceptable Deck''']]
 
;(A) [[RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies#SBSDECKS|'''Acceptable Deck''']]
;(B) '''Anchor''': to CSA Z91-M90 - Poured concrete shown, see anchor manufacturer's attachment for other wall types and attachment methods.
+
;(B) '''Anchor''': Anchor selection and attachment details are the responsibility of the Design Authority
;(C) '''Anchor Eye''': to CSA Z91-M90
+
;(C) '''Anchor Eye'''
 
;(D) '''Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants''': Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished  roof surfacing.
 
;(D) '''Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants''': Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished  roof surfacing.
 
;(E) '''Plywood''': 15.9 mm (5/8") treated where required.
 
;(E) '''Plywood''': 15.9 mm (5/8") treated where required.

Revision as of 17:05, 15 May 2018

RoofStar Guarantee Standards are blue-linked
SBS Details

10.3.7.3.jpg

1 WORK INCLUDED

(1) Inverted (Protected) Roof Assembly
(2) Counter-flashing
(3) Insulation - XPS
See available insulation products in the Accepted Materials section of this Manual.
(4) Primary Membrane

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Anchor
Anchor selection and attachment details are the responsibility of the Design Authority
(C) Anchor Eye
(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants
Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.
(E) Plywood
15.9 mm (5/8") treated where required.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies

Back to SBS Modified Bitumen Construction Details

Back to Construction Details