Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
m (James Klassen moved page ASM Details:E1.7.8 (Equipment Support Stand / Pipe Flashing) to ASM 11.1 Pipe Flashing) |
|||
Line 9: | Line 9: | ||
[[File:8.1.4.8.1.jpg|class=img-responsive]] | [[File:8.1.4.8.1.jpg|class=img-responsive]] | ||
</div> | </div> | ||
+ | ::Click below for a printable version of this page. | ||
− | + | <div style="width:150px; text-align: left;"> | |
− | + | :[[File:ASM 11.1 Thumb for PDF.jpg|100 px|link=http://rpm.rcabc.org/images/2/25/ASM_11.1_Pipe_Flashing.pdf|'''Print Sheet''']] | |
− | + | </div> | |
− | |||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies# | + | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] |
− | ;(2) | + | ;(2) '''Water Tight Back Up Storm Collar''': Installed where practical. |
− | ;(3) | + | ;(3) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking. |
− | ;(4) ''' | + | ;(4) '''Stainless Steel Drawband''' |
;(5) '''Preformed Penetration Collar''' | ;(5) '''Preformed Penetration Collar''' | ||
;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications. | ;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications. | ||
− | ;(7) ''' | + | ;(7) '''Flange''': Set in two continuous beads of accepted caulking. |
− | ;(8) ''' | + | ;(8) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Separation Layer (Drainage Mat)''']]: Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer. |
− | ;(9) ''' | + | ;(9) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. |
<hr> | <hr> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 21:44, 24 April 2019
RoofStar Guarantee Standards are blue-linked |
ASM Details
WORK INCLUDED
- (1) Architectural Metal Roof Panel
- (2) Water Tight Back Up Storm Collar
- Installed where practical.
- (3) Seal Between Pipe And Flashing
- Continuous tooled bead of accepted caulking.
- (4) Stainless Steel Drawband
- (5) Preformed Penetration Collar
- (6) High-domed Gasketed Cladding-type Screws
- Flange fastened to manufacturer's specifications.
- (7) Flange
- Set in two continuous beads of accepted caulking.
- (8) Separation Layer (Drainage Mat)
- Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (9) Underlayment
- The type of underlay required is determined by roof slope.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for ASM Roof Assemblies