Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Jump to: navigation, search

Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Line 9: Line 9:
 
[[File:8.1.4.2.1.jpg|class=img-responsive]]
 
[[File:8.1.4.2.1.jpg|class=img-responsive]]
 
</div>
 
</div>
</div><!-- COL-MD-6 -->
 
  
 
::Click below for a printable version of this page.
 
::Click below for a printable version of this page.

Revision as of 16:59, 1 August 2019

RoofStar Guarantee Standards are blue-linked
ASM Details

8.1.4.2.1.jpg

Click below for a printable version of this page.
Print Sheet

1 WORK INCLUDED

(1) Underlayment
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(2) Eave Protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(3) Edge Metal Flashing
Installed to manufacturer's printed instructions.
(4) Metal flashing underlayment/separation membrane
required for metal flashings installed on wood substrates.
Note: This application is required on slopes greater than 1:6 (2" in 12") and less than 1:3 (4" in 12").

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for ASM Roof Assemblies

Back to ASM Construction Details

Back to Construction Details