Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
Line 12: | Line 12: | ||
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | :[[File:ASM 11.1.1 Thumb for PDF.jpg|100 px|link=http://rpm.rcabc.org/images/ | + | :[[File:ASM 11.1.1 Thumb for PDF.jpg|100 px|link=http://rpm.rcabc.org/images/7/77/ASM_11.1.1.jpg]] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
Line 18: | Line 18: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM | + | ;(1) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] |
;(2) '''Water Tight Back Up Storm Collar''': Installed where practical. | ;(2) '''Water Tight Back Up Storm Collar''': Installed where practical. | ||
;(3) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking. | ;(3) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking. | ||
;(4) '''Stainless Steel Drawband''' | ;(4) '''Stainless Steel Drawband''' | ||
;(5) '''Preformed Penetration Collar''' | ;(5) '''Preformed Penetration Collar''' | ||
− | ;(6) [[RoofStar Guarantee Standards for ASM | + | ;(6) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications. |
;(7) '''Flange''': Set in two continuous beads of accepted caulking. | ;(7) '''Flange''': Set in two continuous beads of accepted caulking. | ||
− | ;(8) [[RoofStar Guarantee Standards for ASM | + | ;(8) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMSLIP|'''Separation Layer (Drainage Mat)''']]: Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer. |
− | ;(9) [[RoofStar Guarantee Standards for ASM | + | ;(9) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. |
<hr> | <hr> | ||
Line 38: | Line 38: | ||
<hr> | <hr> | ||
− | + | [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems|<i class="fa fa-chevron-circle-right fa" ></i> RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems]] | |
− | [[RoofStar Guarantee Standards for ASM | ||
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']] | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']] | ||
− | |||
− |
Revision as of 15:43, 5 October 2020
RoofStar Guarantee Standards are blue-linked |
ASM Details
WORK INCLUDED
- (1) Architectural Metal Roof Panel
- (2) Water Tight Back Up Storm Collar
- Installed where practical.
- (3) Seal Between Pipe And Flashing
- Continuous tooled bead of accepted caulking.
- (4) Stainless Steel Drawband
- (5) Preformed Penetration Collar
- (6) High-domed Gasketed Cladding-type Screws
- Flange fastened to manufacturer's specifications.
- (7) Flange
- Set in two continuous beads of accepted caulking.
- (8) Separation Layer (Drainage Mat)
- Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (9) Underlayment
- The type of underlay required is determined by roof slope.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems