Difference between revisions of "Miscellaneous wordings 1"

Jump to: navigation, search

Difference between revisions of "Miscellaneous wordings 1"

(D)
(C)
Line 89: Line 89:
 
|}
 
|}
  
===C===
+
===SBS 5/10-year===
  
 
{|            class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;vertical-align:top;text-align:top;"                                                                                                                                                                                                                                                                                                                                                     
 
{|            class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;vertical-align:top;text-align:top;"                                                                                                                                                                                                                                                                                                                                                     

Revision as of 21:08, 17 November 2020


1 A

Table 9.1 Single-ply Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Conventionally Insulated / Uninsulated
Single-Ply Systems
Loose-
laid
PMR
Systems
Built-in
Gutters
Roof as a
Platform
Grade-level
Water-
proofing
Mechanically
Fastened
Self-adhered Adhered Adhered
(Fleece-
backed)
Ballasted Adhered Adhered All
applications
Adhered
Membrane Type, Reinforcement & Grade mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced) 1.524 (60) 1.524 (60) 1.143 (45) N/A 1.143 (45) 1.524 (60) 1.524 (60) 1.524 (60) N/A
EPDM (unreinforced) N/A 1.524 (60) 1.143 (45) 2.794 (110) 1.143 (45) 1.524 (60) 1.524 (60) 1.524 (60) N/A
TPO 1.143 (45) 1.524 (60) 1.143 (45) 2.794 (110) 1.143 (45) 1.524 (60) 1.524 (60) 1.524 (60) N/A
PVC N/A 1.270 (50) 2.667 (105) N/A 1.270 (50) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)

2 B

Table 9.2 Single-ply Membranes: RoofStar 15-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Conventionally Insulated / Uninsulated
Single-Ply Systems
Loose-
laid
PMR
Systems
Built-in
Gutters
Roof as a
Platform
Grade-level
Water-
proofing
Mechanically
Fastened
Self-adhered Adhered Adhered
(Fleece-
backed)
Ballasted Adhered Adhered All
applications
Adhered
Membrane Type, Reinforcement & Grade mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced) 1.524 (60) 1.524 (60) 1.524 (60) N/A N/A 1.524 (60) 2.032 (80) 2.032 (80) N/A
EPDM (unreinforced) N/A 1.524 (60) 1.524 (60) 2.790 (110) N/A 1.524 (60) 2.032 (80) 2.032 (80) N/A
TPO 1.524 (60) 1.524 (60) 1.524 (60) 2.790 (110) N/A 1.524 (60) 2.286 (90) 2.286 (90) N/A
PVC 1.524 (60) N/A 1.524 (60) 2.670 (105) N/A 1.524 (60) 2.286 (90) 2.286 (90) N/A

3 SBS 5/10-year

Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Conventionally Insulated / Uninsulated
2-Ply Systems
PMR
Systems
Built-in
Gutters
Roof as a
Platform
Grade-level
Water-
proofing
Single-ply
Cap
Mech.
fastened
Heat-
welded
Self-
adhered
Hot-
mopped
Cold-
adhered
Puncture
Resist.
Heat-welded / Adhered
Puncture Resistance
Adhered
Puncture Resistance
Heat-welded / Adhered
Puncture Resistance
Heat-welded / Adhered
Puncture Resistance
As specified
Puncture Resistance
Membrane Type, Reinforcement & Grade mm mm mm mm mm (N) mm (N) mm (N) mm (N) mm (N) mm (N)
Base Sheet (fibreglass) - Grade 3 2.30 2.30 2.30 2.20 2.20 3.00 3.00 3.00
Base Sheet (polyester) - Grade 3 2.50 2.50 2.50 2.20 2.20 400 3.00 3.00 3.50 400 3.00
Base Sheet (composite) - Grade 3 2.30 2.30 2.30 2.20 2.20 400 3.00 3.00 3.50 3.00
Film Cap Sheet (fibreglass) - Grade 2 4.00 3.30 3.30 3.30 3.30
Film Cap Sheet (polyester) - Grade 2 4.00 3.50 3.50 3.50 400 3.00 400 3.50 400 4.00 400 3.00 400 4.00 400
Film Cap Sheet (composite) - Grade 2 4.00 3.30 3.30 3.30 400 3.00 400 3.30 400 4.00 400 3.00 400 4.00 400
Granular Cap Sheet (fibreglass) - Grade 1 4.00 3.30 3.30 3.30 400 3.30
Granular Cap Sheet (polyester) - Grade 1 4.00 3.50 3.50 3.50 400 3.00 400 3.50 400 4.00 400 3.00 400 4.00 400
Granular Cap Sheet (composite) - Grade 1 4.00 4.00 3.30 3.30 400 3.00 400 3.00 400 4.00 400 3.00 400 4.00 400

4 SBS 15-year

Table 9.2 SBS-modified Bituminous Membranes: RoofStar 15-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Conventionally Insulated / Uninsulated
2-Ply Systems
PMR
Systems
Built-in
Gutters
Roof as a
Platform
Grade-level
Water-
proofing
Single-ply
Cap
Mech.
fastened
Heat-
welded
Self-
adhered
Hot-
mopped
Cold-
adhered
Puncture
Resist.
Heat-welded / Adhered
Puncture Resistance
Adhered
Puncture Resistance
Heat-welded / Adhered
Puncture Resistance
Heat-welded / Adhered
Puncture Resistance
As specified
Puncture Resistance
Membrane Type, Reinforcement & Grade mm mm mm mm mm (N) mm (N) mm (N) mm (N) mm (N) mm (N)
Base Sheet (fibreglass) - Grade 3 3.00
Base Sheet (polyester) - Grade 3 2.50 2.50 2.50 2.50 400 3.00 3.00 3.50 3.00
Base Sheet (composite) - Grade 3 X X X X X X X X X X X X X X X X
Film Cap Sheet (fibreglass) - Grade 2 X X X X X X X X X X X X X X X X
Film Cap Sheet (polyester) - Grade 2 X X X X X X X X X X X X X X X X
Film Cap Sheet (composite) - Grade 2 X X X X X X X X X X X X X X X X
Granular Cap Sheet (fibreglass) - Grade 1 X X X X X X X X X X X X X X X X
Granular Cap Sheet (polyester) - Grade 1 X X X X X X X X X X X X X X X X
Granular Cap Sheet (composite) - Grade 1 X X X X X X X X X X X X X X X X