Difference between revisions of "Table Drafts 5"

Jump to: navigation, search

Difference between revisions of "Table Drafts 5"

(Created page with "__NOTOC__ ===Part 9: EPDM Table (Combined 5, 10, 15) REV=== {| class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;ve...")
 
(Part 9: 2-ply Model (Combined 5, 10, 15))
Line 207: Line 207:
 
|            rowspan="1" style="text-align:center;background-color:#E9967A"            |    5/10  ||  colspan="6" rowspan="1" style="text-align:center;"    | 6.00                ||    rowspan="1" style="text-align:center;"            |    6.00  ||    rowspan="1" style="text-align:center;"            |  N/A ||    rowspan="1" style="text-align:center;"            |    6.00  ||    rowspan="1" style="text-align:center;width=200px;"            |    N/A
 
|            rowspan="1" style="text-align:center;background-color:#E9967A"            |    5/10  ||  colspan="6" rowspan="1" style="text-align:center;"    | 6.00                ||    rowspan="1" style="text-align:center;"            |    6.00  ||    rowspan="1" style="text-align:center;"            |  N/A ||    rowspan="1" style="text-align:center;"            |    6.00  ||    rowspan="1" style="text-align:center;width=200px;"            |    N/A
 
|-   
 
|-   
|              rowspan="1" style="text-align:center;background-color:#FA8072"            |    15  ||  colspan="6" rowspan="1" style="text-align:center;"    | 7.00                 ||    rowspan="1" style="text-align:center;"            |     7.00 ||    rowspan="1" style="text-align:center;"            |    N/A ||    rowspan="1" style="text-align:center;"            |    7.00 ||    rowspan="1" style="text-align:center;width=200px;"            |  N/A
+
|              rowspan="1" style="text-align:center;background-color:#FA8072"            |    15  ||  colspan="6" rowspan="1" style="text-align:center;"    | 6.50                 ||    rowspan="1" style="text-align:center;"            |   6.50 ||    rowspan="1" style="text-align:center;"            |    N/A ||    rowspan="1" style="text-align:center;"            |    6.50 ||    rowspan="1" style="text-align:center;width=200px;"            |  N/A
 
|-   
 
|-   
 
|  colspan="14" style="border:none;background-color:#E7E9E9;"  |
 
|  colspan="14" style="border:none;background-color:#E7E9E9;"  |

Revision as of 19:19, 12 January 2021


1 Part 9: EPDM Table (Combined 5, 10, 15) REV

Table 9.1 EPDM Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm and mils)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened;
Induction
Welded*
Adhered Adhesive-
applied;
Self-
adhered
Loose-laid Adhered Adhered
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced)
5 1.524 (60) 1.524 (60) 1.143 (45) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 2.286 (90) X N/A N/A 1.524 (60) X N/A X
EPDM (unreinforced)
5 X 1.524 (60) 1.143 (45) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 X 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 X X 2.286 (90) 2.286 (90) 2.286 (90) X 2.286 (90) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

2 Part 9: TPO Table (Combined 5, 10, 15) REV

Table 9.1 TPO Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened;
Induction
Welded*
Adhered Adhesive-
applied;
Self-
adhered
Loose-laid Adhered Adhered
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
TPO
5 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80) X 2.032 (80) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

3 Part 9: PVC Table (Combined 5, 10, 15) REV

Table 9.1 PVC Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened;
Induction
Welded*
Adhered Adhesive-
applied;
Self-
adhered
Loose-laid Adhered Adhered
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
PVC
5 1.270 (50) X 1.270 (50) 1.270 (50) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
10 1.524 (60) X 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) X 2.032 (80) 2.032 (80) 2.032 (80) X 2.032 (80) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

4 Part 9: 2-ply Model (Combined 5, 10, 15)

Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5, 10 and 15-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded;
Adhesive-
applied;
Self-
adhered

Heat-
welded;
Adhered
Puncture Resistance Heat-
welded;
Adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness
5/10 6.00 6.00 N/A 6.00 N/A
15 6.50 6.50 N/A 6.50 N/A
Base (Fibreglass) - Gr. 3
5/10 2.30 2.30 2.30 2.20 2.20 X X X X X
15 X 2.50 2.50 2.50 2.50 X X X X X
Base (Composite fibreglass) - Gr. 3
5/10 2.30 2.30 2.30 2.20 2.20 2.50 2.20 X 2.20 X
15 X 2.50 2.50 2.50 2.50 2.90 2.50 X 2.50 X
Base (Polyester) - Gr. 3
5/10 2.50 2.50 2.50 2.20 2.20 2.50 2.20 X 2.20 X
15 X 2.50 2.50 2.50 2.50 2.90 2.50 X 2.50 X
Base (Composite) - Gr. 3
5/10 2.30 2.30 2.30 2.20 2.20 2.50 2.20 X 2.20 X
15 X 2.50 2.50 2.50 2.50 2.90 2.50 X 2.50 X
Factory Laminated Base (panel)
5/10 2.20 X 2.20 N/A X N/A
15 2.20 X 2.20 N/A X N/A
Film Cap (Fibreglass) - Gr. 2
5/10 X 4.00 3.30 3.30 3.30 X X X X X
15 X X X X X X X X X X
Film Cap (Polyester) - Gr. 2
5/10 X 4.00 3.50 3.50 3.50 3.00 3.00 400 3.00 400
15 X 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Film Cap (Composite) - Gr. 2
5/10 X 4.00 3.30 3.30 3.30 3.00 3.00 400 3.00 400
15 X 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granule Cap (Fibreglass) - Gr. 1
5/10 X 4.00 3.30 3.30 3.30 X X X X X
15 X 4.00 4.00 4.00 4.00 X X X X X
Granule Cap (Polyester) - Gr. 1
5/10 X 4.00 3.50 3.50 3.50 3.50 3.00 400 3.00 400
15 X 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granule Cap (Composite) - Gr. 1
5/10 X 3.30 4.00 3.30 3.30 3.50 3.00 400 3.00 400
15 X 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400