=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[SBS Roof Systems Standard#AIRVAPOUR|'''Air/Vapour barrier''']]: Self-adhered membrane, as specified in design. Install following manufacturer’s requirements. |
− | ;(2) [[ | + | ;(2) [[SBS Roof Systems Standard#GENERAL|'''Roof system''']]: Conventionally insulated system shown (refer to the membrane Standard for requirements). |
− | ;(3) [[ | + | ;(3) [[SBS Roof Systems Standard#MEMBRANES|'''Field Membrane''']]: SBS-modified bituminous system shown (see Part 9 for standards) |
− | ;(4) [[ | + | ;(4) [[SBS Roof Systems Standard#PERIMETERS|'''Self-adhered membrane (pre-flashing)''']]: Apply over rough sill or sill woodwork. Prime as required. |
− | ;(5) [[ | + | ;(5) [[SBS Roof Systems Standard#DOOR|'''Metal water-stop flashing''']]: Dimensions as specified in design. Mechanically attach to inside face of door sill. Cut flashing to fit opening width. |
− | ;(6) [[ | + | ;(6) [[SBS Roof Systems Standard#PERIMETERS|'''Membrane flashing''']]: Base membrane shown. Install to overlap and seal in metal water-stop flashing. |
− | ;(7) [[ | + | ;(7) [[SBS Roof Systems Standard#DOOR|'''Membrane gussets''']]: Install in corners to seal joints. |
− | ;(8) [[ | + | ;(8) [[SBS Roof Systems Standard#CAPCOUNTERBASE|'''Metal base flashing (under door)''']]: Optional; protection for membrane when pavers are installed (shown), or when exposed membrane is vulnerable to damage. Mechanical fasteners must be at least 87.5 mm (3-1/2”) above the drainage plane. |
− | ;(9) [[ | + | ;(9) [[SBS Roof Systems Standard#PERIMETERS|'''Membrane flashing''']]: Applicable for exterior-insulated walls. Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others). Mechanically secure membrane (metal base flashing used for securement in this detail). |
− | ;(10) [[ | + | ;(10) [[SBS Roof Systems Standard#CAPCOUNTERBASE|'''Metal base flashing (walls)''']]: Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement. |
− | ;(11) [[ | + | ;(11) [[SBS Roof Systems Standard#PLATFORM|'''Pavers and pedestals''']]: May be installed by others, if specified. See '''Part 14''' for material and application requirements. Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage. |
<hr> | <hr> | ||
Line 43: | Line 43: | ||
− | [[ | + | [[SBS Roof Systems Standard |<i class="fa fa-chevron-circle-left fa" ></i> Back to ''RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies'']] |
− | [[SBS | + | [[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''SBS Modified Bitumen Construction Details'']] |
− | |||
− |
Revision as of 14:42, 27 August 2021
RoofStar Guarantee Standards are blue-linked |
SBS Details
1 WORK INCLUDED
- (1) Air/Vapour barrier
- Self-adhered membrane, as specified in design. Install following manufacturer’s requirements.
- (2) Roof system
- Conventionally insulated system shown (refer to the membrane Standard for requirements).
- (3) Field Membrane
- SBS-modified bituminous system shown (see Part 9 for standards)
- (4) Self-adhered membrane (pre-flashing)
- Apply over rough sill or sill woodwork. Prime as required.
- (5) Metal water-stop flashing
- Dimensions as specified in design. Mechanically attach to inside face of door sill. Cut flashing to fit opening width.
- (6) Membrane flashing
- Base membrane shown. Install to overlap and seal in metal water-stop flashing.
- (7) Membrane gussets
- Install in corners to seal joints.
- (8) Metal base flashing (under door)
- Optional; protection for membrane when pavers are installed (shown), or when exposed membrane is vulnerable to damage. Mechanical fasteners must be at least 87.5 mm (3-1/2”) above the drainage plane.
- (9) Membrane flashing
- Applicable for exterior-insulated walls. Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others). Mechanically secure membrane (metal base flashing used for securement in this detail).
- (10) Metal base flashing (walls)
- Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement.
- (11) Pavers and pedestals
- May be installed by others, if specified. See Part 14 for material and application requirements. Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage.
2 RELATED WORK BY OTHERS
- (A) Wall and cladding
- Generic and representative only.
- (B) WRB (Water Resistant Barrier)
- Generic and representative only.
- (C) Door and jamb assembly
- Generic and representative only.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.