Difference between revisions of "SBS Fire Separation Wall"
Difference between revisions of "SBS Fire Separation Wall"
Line 15: | Line 15: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[SBS Roof Systems Standard#SBSBASE|'''Primary Roof Membrane''']] |
− | ;(2) [[ | + | ;(2) [[SBS Roof Systems Standard#SBS-STRIPPING|'''Base Membrane Flashing''']] |
;(3) '''Non-combustible Insulation''': Optional (For condensation control) Cellular glass board insulation complying to ASTM C552-00 <b>OR</b> mineral fiber insulation conforming to CAN / CGSB 51.31-M84 and ASTM E84. | ;(3) '''Non-combustible Insulation''': Optional (For condensation control) Cellular glass board insulation complying to ASTM C552-00 <b>OR</b> mineral fiber insulation conforming to CAN / CGSB 51.31-M84 and ASTM E84. | ||
− | ;(4) [[ | + | ;(4) [[SBS Roof Systems Standard#METALCAP-SBS|'''Base Metal Flashing''']]: S-Lock joints and concealed discontinuous clips required. Do not fasten to block firewall. (Optional – Metal base flashing may be installed on lower wall area.) |
;(5) '''Water Channeling Clip''': (See inset) Concealed clip designed with ribs to channel water under standing seam joint with notch to allow water to escape, <b>OR</b> standing seam joints to be soldered, <b>OR</b> an additional layer of metal flashing with offsetting joints. Do <b><u>NOT</u></b> place combustible materials over top of firewall. | ;(5) '''Water Channeling Clip''': (See inset) Concealed clip designed with ribs to channel water under standing seam joint with notch to allow water to escape, <b>OR</b> standing seam joints to be soldered, <b>OR</b> an additional layer of metal flashing with offsetting joints. Do <b><u>NOT</u></b> place combustible materials over top of firewall. | ||
− | ;(6) [[ | + | ;(6) [[SBS Roof Systems Standard#METALCAP-SBS|'''Metal Cap Flashing''']]: Standing seam joints and concealed continuous or discontinuous clips required. |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[SBS Roof Systems Standard#SBSDECKS|'''Acceptable Supporting Deck Structure''']] |
;(B) '''Cant''' | ;(B) '''Cant''' | ||
− | ;(C) [[ | + | ;(C) [[SBS Roof Systems Standard#SBSWALLSUB|'''Acceptable Wall Surface - Plywood''']] |
;(D) '''Wood Frame Wall''' | ;(D) '''Wood Frame Wall''' | ||
;(E) '''Block or Concrete Firewall''' | ;(E) '''Block or Concrete Firewall''' | ||
Line 41: | Line 41: | ||
− | [[ | + | [[SBS Roof Systems Standard |<i class="fa fa-chevron-circle-left fa" ></i> Back to ''RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies'']] |
− | [[SBS | + | [[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''SBS Modified Bitumen Construction Details'']] |
− | |||
− |
Revision as of 14:47, 27 August 2021
RoofStar Guarantee Standards are blue-linked |
SBS Details
1 WORK INCLUDED
- (1) Primary Roof Membrane
- (2) Base Membrane Flashing
- (3) Non-combustible Insulation
- Optional (For condensation control) Cellular glass board insulation complying to ASTM C552-00 OR mineral fiber insulation conforming to CAN / CGSB 51.31-M84 and ASTM E84.
- (4) Base Metal Flashing
- S-Lock joints and concealed discontinuous clips required. Do not fasten to block firewall. (Optional – Metal base flashing may be installed on lower wall area.)
- (5) Water Channeling Clip
- (See inset) Concealed clip designed with ribs to channel water under standing seam joint with notch to allow water to escape, OR standing seam joints to be soldered, OR an additional layer of metal flashing with offsetting joints. Do NOT place combustible materials over top of firewall.
- (6) Metal Cap Flashing
- Standing seam joints and concealed continuous or discontinuous clips required.
2 RELATED WORK BY OTHERS
- (A) Acceptable Supporting Deck Structure
- (B) Cant
- (C) Acceptable Wall Surface - Plywood
- (D) Wood Frame Wall
- (E) Block or Concrete Firewall
- (F) Sloping Mortar
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies