Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"
Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"
Line 28: | Line 28: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
;(A) [[SBS Roof Systems Standard#SBSDECKS|'''Acceptable Supporting Deck Structure''']] | ;(A) [[SBS Roof Systems Standard#SBSDECKS|'''Acceptable Supporting Deck Structure''']] | ||
− | ;(B) '''Plumbing Stack''': Extend to match top of metal flashing. | + | ;(B) '''Plumbing Stack''': Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems. |
;(C) '''Wood Blocking''': Optional. | ;(C) '''Wood Blocking''': Optional. | ||
;(D) [[SBS Roof Systems Standard#SBSPENETRATIONFLASHING|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck. | ;(D) [[SBS Roof Systems Standard#SBSPENETRATIONFLASHING|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck. | ||
Line 38: | Line 38: | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
− | '''NOTE''': | + | '''NOTE''': See the [[SBS Roof Systems Standard | '''Standard''']] for additional requirements. |
− | |||
<hr> | <hr> | ||
+ | [[SBS Roof Systems Standard|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies'']] | ||
− | [[SBS Roof | + | [[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''SBS Modified Bitumen Construction Details'']] |
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Revision as of 17:51, 27 August 2021
RoofStar Guarantee Standards are blue-linked |
SBS Details
1 WORK INCLUDED
- (1) Supporting Deck Overlay
- If required by design authority.
- (2) Air or Vapour Control Layers
- If required by design authority.
- (3) Insulation
- Mechanically fastened. See available insulation products in the Accepted Materials section of this Manual.
- (4) Insulation Overlay
- (5) Primary Membrane and Membrane Protection
- (6) Mastic
- As approved by manufacturer.
- (7) Membrane Flashing
- Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems.
- (8) Storm Collar, Typical Lead Cap or Typical Aluminum Cap
- Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing.
2 RELATED WORK BY OTHERS
- (A) Acceptable Supporting Deck Structure
- (B) Plumbing Stack
- Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems.
- (C) Wood Blocking
- Optional.
- (D) Metal Flashing
- Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
- (E) Typical Aluminum Cap
- For use with aluminum flashing. See requirements for Settlement Caps on strip-in plumbing flashings.
- (F) Typical Lead Cap
- For use with lead flashing.
- (G) Storm Collar
- Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings.
NOTE: See the Standard for additional requirements.