Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
(Created page with "File:8.1.4.8.1.jpg === WORK INCLUDED === (1) <b>Underlayment</b>: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2)....") |
|||
Line 1: | Line 1: | ||
[[File:8.1.4.8.1.jpg]] | [[File:8.1.4.8.1.jpg]] | ||
+ | |||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
Line 20: | Line 21: | ||
(9) <b>Water Tight Back Up Storm Collar</b>: Installed where practical. | (9) <b>Water Tight Back Up Storm Collar</b>: Installed where practical. | ||
+ | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === |
Revision as of 17:59, 21 December 2015
1 WORK INCLUDED
(1) Underlayment: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).
(2) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Architectural Metal Roof Panel
(4) Flange: Set in two continuous beads of accepted caulking.
(5) Preformed Penetration Collar
(6) High Domed, Gasketed, Cladding Type Screws: Flange fastened to manufacturer’s specifications.
(7) Seal Between Pipe And Flashing: Continuous tooled bead of accepted caulking.
(8) Stainless Steel Drawband
(9) Water Tight Back Up Storm Collar: Installed where practical.
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Location Of Penetrations - must not interfere with standing seams or trapezoidal and intermediate ribs.
(C) Opening In Roof Deck - must be large enough to allow for thermal movement of metal roof panels.
(D) Pipe Or Support Stand
NOTE: * Refer to RGC Guarantee Standards for additional requirements.