<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[SBS Roof Systems Standard# | + | ;(1) [[SBS Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If required by ''Design Authority''. |
− | ;(2) [[SBS Roof Systems Standard# | + | ;(2) [[SBS Roof Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by ''Design Authority''. |
− | ;(3) [[SBS Roof Systems Standard# | + | ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. |
− | ;(4) [[SBS Roof Systems Standard# | + | ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: |
− | ;(5) [[SBS Roof Systems Standard# | + | ;(5) [[SBS Roof Systems Standard#PART_9|'''Primary Membrane''']] and [[SBS Roof Systems Standard#PART_9| '''Membrane Protection''']] |
;(6) '''Mastic''': As approved by manufacturer. | ;(6) '''Mastic''': As approved by manufacturer. | ||
− | ;(7) [[SBS Roof Systems Standard# | + | ;(7) [[SBS Roof Systems Standard#PART_10|'''Membrane Flashing''']]: Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems. |
;(8) '''Storm Collar, Typical Lead Cap or Typical Aluminum Cap''': Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing. | ;(8) '''Storm Collar, Typical Lead Cap or Typical Aluminum Cap''': Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing. | ||
Line 29: | Line 29: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[SBS Roof Systems Standard# | + | ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure''']] |
;(B) '''Plumbing Stack''': Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems. | ;(B) '''Plumbing Stack''': Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems. | ||
;(C) '''Wood Blocking''': Optional. | ;(C) '''Wood Blocking''': Optional. | ||
− | ;(D) [[SBS Roof Systems Standard# | + | ;(D) [[SBS Roof Systems Standard#PART_11|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck. |
− | ;(E) '''Typical Aluminum Cap''': For use with aluminum flashing. See requirements for [[ | + | ;(E) '''Typical Aluminum Cap''': For use with aluminum flashing. See requirements for [[SBS Roof Systems Standard#PART_11|'''Settlement Caps''']] on strip-in plumbing flashings. |
;(F) '''Typical Lead Cap''': For use with lead flashing. | ;(F) '''Typical Lead Cap''': For use with lead flashing. | ||
;(G) '''Storm Collar''': Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings. | ;(G) '''Storm Collar''': Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings. |
Revision as of 21:43, 1 September 2021
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority. The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks |
SBS Details
1 WORK INCLUDED
- (1) Supporting Deck Overlay
- If required by Design Authority.
- (2) Air or Vapour Control Layers
- If required by Design Authority.
- (3) Insulation
- Mechanically fastened. See available insulation products in the Accepted Materials section of this Manual.
- (4) Insulation Overlay
- (5) Primary Membrane and Membrane Protection
- (6) Mastic
- As approved by manufacturer.
- (7) Membrane Flashing
- Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems.
- (8) Storm Collar, Typical Lead Cap or Typical Aluminum Cap
- Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing.
2 RELATED WORK BY OTHERS
- (A) Acceptable Supporting Deck Structure
- (B) Plumbing Stack
- Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems.
- (C) Wood Blocking
- Optional.
- (D) Metal Flashing
- Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
- (E) Typical Aluminum Cap
- For use with aluminum flashing. See requirements for Settlement Caps on strip-in plumbing flashings.
- (F) Typical Lead Cap
- For use with lead flashing.
- (G) Storm Collar
- Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings.
NOTE: See the Standard for additional requirements.