Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | {{Template:RPM Info}} | ||
+ | |||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>WP Details:F1.7.1(Wearing Course - Concrete Pavers)</big></big></big></big></big> | ||
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center" | {| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center" | ||
− | | colspan="2" | <big>''''' | + | | colspan="2" | <big>'''''Notice to Reader'''''</big> |
+ | |- | ||
+ | | style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> | ||
|} | |} | ||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
Line 7: | Line 17: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File:9.6.1.jpg|class=img-responsive]] | + | [[File:9.6.1.jpg| link=http://rpm.rcabc.org/images/2/2b/9.6.1.jpg | class=img-responsive]] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
Line 14: | Line 24: | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | (1) [ | + | ;(1) [[Grade-level Waterproofing Standard#WPMEMBRANE | '''Primary Waterproofing Membrane''']]: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces'''] and Membrane Manufacturer's installation specifications. |
− | + | ;(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications. | |
− | (2) | + | ;(3) [[Grade-level Waterproofing Standard#WPPROTECTION | '''Protection Board/Mat''']]: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces'''] |
− | + | ;(4) [[Grade-level Waterproofing Standard#WPWEARING | '''Pedestal''']]: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and leveling. | |
− | (3) [ | + | ;(5) [[Grade-level Waterproofing Standard#WPWEARING |'''Pavers''']]: Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24"). |
− | |||
− | (4) [ | ||
− | |||
− | ( | ||
=== WORK BY OTHERS === | === WORK BY OTHERS === | ||
− | (A) [ | + | ;(A) [[Grade-level Waterproofing Standard#WPDECK |'''Acceptable Deck''']]: Concrete slab depicted. |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
− | '''NOTE''': | + | '''NOTE''': See the [[Grade-level Waterproofing Standard | '''Standard''']] for additional requirements. |
<hr> | <hr> | ||
+ | [[Grade-level Waterproofing System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Grade-level Waterproofing Construction Details'']] | ||
+ | [[Main Page | <i class="fa fa-home fa"></i> Home]] | ||
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} | |
− | |||
− | |||
− | |||
− |
Latest revision as of 21:14, 7 September 2021
Division D - Construction Details
WP Details:F1.7.1(Wearing Course - Concrete Pavers)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority. The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks |
Waterproofing Details for Plazas, Promenades and Terraces
1 WORK INCLUDED
- (1) Primary Waterproofing Membrane
- Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.
- (2) Membrane Primer or Adhesive
- Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
- (3) Protection Board/Mat
- Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces
- (4) Pedestal
- Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and leveling.
- (5) Pavers
- Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24").
2 WORK BY OTHERS
- (A) Acceptable Deck
- Concrete slab depicted.
NOTE: See the Standard for additional requirements.
Back to Grade-level Waterproofing Construction Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.