| + | <big><big>Division E - General Information</big></big> |
| + | <hr> |
| + | <big><big><big><big><big>Insulating the Roof</big></big></big></big></big> |
| + | <div style="width:300px; text-align: left;"> |
| + | [[File:Low-slope Roof Insulation.jpg|300 px]] |
| + | </div> |
| + | {| class="wikitable" | style="color: black; background-color: #ffffcc; width: 100%;" |
| + | | colspan="2" | '''NOTICE TO READER''': This is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. |
| + | |} |
| + | == General == |
| Buildings are designed to provide an interior environment (or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this design and must perform several functions. As part of the roof assembly, properly designed and installed roof insulation provides the following benefits: | | Buildings are designed to provide an interior environment (or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this design and must perform several functions. As part of the roof assembly, properly designed and installed roof insulation provides the following benefits: |
| * It reduces energy costs and provides a comfortable interior environment by resisting heat loss. | | * It reduces energy costs and provides a comfortable interior environment by resisting heat loss. |
Line 11: |
Line 29: |
| * By eliminating the problem of interior condensation, the insulation creates the possibility of moisture (vapour or liquid) trapped within the roof system. This can lead to numerous problems and may create the need for a vapour retarder. | | * By eliminating the problem of interior condensation, the insulation creates the possibility of moisture (vapour or liquid) trapped within the roof system. This can lead to numerous problems and may create the need for a vapour retarder. |
| * The frequency of thermal expansion and contraction in the membrane may be increased, thereby increasing the stresses on the membrane, which can result in membrane splitting. | | * The frequency of thermal expansion and contraction in the membrane may be increased, thereby increasing the stresses on the membrane, which can result in membrane splitting. |
− | A protected membrane roof assembly (PMR) may eliminate some of the possible disadvantages, but this assembly has its own characteristics (see Section 3.13 <i>Protected Membrane and Modified Protected Membrane Roof Assemblies</i>). | + | A protected membrane roof assembly (PMR) may eliminate some of the possible disadvantages, but this assembly has its own characteristics (see [http://rpm.rcabc.org/index.php?title=Protected_and_Modified_Protected_Roof_Systems '''Protected and Modified Protected Roof Systems''']). |
| | | |
− | ==== Theory ====
| + | === Theory === |
| The function of insulation is to retard the flow of heat energy. Heat may flow in three ways: | | The function of insulation is to retard the flow of heat energy. Heat may flow in three ways: |
| * Conduction: the transfer of heat energy through direct contact molecule to molecule. | | * Conduction: the transfer of heat energy through direct contact molecule to molecule. |
Line 68: |
Line 86: |
| If the space between the structural roof deck and the suspended ceiling is used as a return-air plenum, only R-values above the plenum should be considered. | | If the space between the structural roof deck and the suspended ceiling is used as a return-air plenum, only R-values above the plenum should be considered. |
| | | |
− | ==== Installation ====
| + | ===Installation=== |
| The following procedures for installing insulation in roof systems should be followed: | | The following procedures for installing insulation in roof systems should be followed: |
− |
| |
| # On steel roof decks, deck flutes and felts should normally run in parallel alignment and be perpendicular to the roof slope. | | # On steel roof decks, deck flutes and felts should normally run in parallel alignment and be perpendicular to the roof slope. |
| # On steel roof decks, insulation boards should be firmly supported by steel deck flanges. When only one layer of insulation is installed, the long dimension of insulation boards should not cantilever over steel deck flutes. | | # On steel roof decks, insulation boards should be firmly supported by steel deck flanges. When only one layer of insulation is installed, the long dimension of insulation boards should not cantilever over steel deck flutes. |
− | # A staggered double-layer insulation system may provide the following benefits: | + | # A staggered double-layer insulation system may provide the following benefits: |
− | ** elimination of thermal bridges, where leakage of heating or cooling energy may occur.
| + | ::*elimination of thermal bridges, where leakage of heating or cooling energy may occur. |
− | ** reduced ridging, by eliminating through-joint migration of moisture vapour into the membrane, and subsequent deformation.
| + | ::*reduced ridging, by eliminating through-joint migration of moisture vapour into the membrane, and subsequent deformation. |
− | ** reduced ridging and splitting in the roof membrane.
| + | ::*reduced ridging and splitting in the roof membrane. |
− | # The edges of insulation boards should be square, flush and have moderate contact with the edges of adjacent insulation boards. End joints between adjacent insulation boards should be staggered.
| + | |
− | # For heat sensitive insulations and heat insensitive foamed insulations, <i>RGC Guarantee Standards</i> should be consulted for fibreboard overlay requirements for Five (5) or Ten (10) RoofStar Guarantee requirements.
| + | The edges of insulation boards should be square, flush and have moderate contact with the edges of adjacent insulation boards. End joints between adjacent insulation boards should be staggered. For heat sensitive insulation and heat insensitive foamed insulation, RoofStar Guarantee Standards should be consulted for fibreboard overlay requirements for Five (5) or Ten (10) '''''RoofStar Guarantee''''' requirements. |
− | # The specifier should not simply reference the thermal performance for a roof assembly by specifying the total R-value. The generic type, thickness, C-value, and applicable standards of the insulation required for application should also be specified.
| + | |
| + | The specifier should not simply reference the thermal performance for a roof assembly by specifying the total R-value. The generic type, thickness, C-value, and applicable standards of the insulation required for application should also be specified. |
| | | |
| === Desirable Properties === | | === Desirable Properties === |
Line 95: |
Line 113: |
| # <b> Attachment Capability:</b> its surfaces would accommodate secure attachment by traditional methods (roofing nails, or screws and plates). | | # <b> Attachment Capability:</b> its surfaces would accommodate secure attachment by traditional methods (roofing nails, or screws and plates). |
| | | |
− | The remaining sections of Section 3.6 will discuss some of the roof insulations available in British Columbia. This includes generic information on the insulation type, and product information for some of the RGC Accepted Materials. The generic information will discuss the properties of the materials relative to their use and to similar materials. The product information that has been included is taken from referenced publications.
| |
| | | |
− | ==== Required Properties <b>RGC ACCEPTED INSULATION - QUICK REFERENCE CHART</b> ====
| + | The remainder of this section will provide information about types of the roof insulation available in British Columbia. This includes generic information and links to other sections of this Manual, to product information for RoofStar-accepted Materials. The generic information discusses the properties of the materials relative to their use and to similar materials. Any product information that has been included is taken from referenced publications. |
| + | |
| + | <hr> |
| | | |
| + | ==Heat-resistant Insulation== |
| + | <div id=3.7Polyisocyanurate> |
| | | |
− | TBA
| + | ===Polyisocyanurate Foam=== |
| + | {{Template:Insulation (Polyiso)}} |
| + | <div id=4.0Mineral> |
| | | |
− | === Tapered Roof Insulation Systems === | + | ===Mineral Fibre Roof Insulation=== |
− | Tapered roof insulation systems are generally available in three forms:
| + | Mineral fibre roof insulations are composed of rock fibres with a thermoset resin and surfaced with glass fibre scrim on the top surface. These boards can provide a suitable surface for directly mopped bituminous membranes, however, a minimum one layer fibreboard overlay is recommended. |
− | * Field-sloped lightweight insulating concrete roof fill
| |
− | * Field-tapered perlitic insulation boards
| |
− | * Factory-tapered insulation boards
| |
| | | |
− | For a discussion of field-sloped lightweight insulating concrete roof fill systems see Section 3.3, <i>Roof Decks.</i>
| + | Mineral fibre roof insulation may provide the following properties and advantages: |
| + | * compatible with asphalt |
| + | * compatible with most roof systems |
| + | * resistant to thermal conductivity |
| + | * excellent resistance to the effects of moisture |
| + | * resistant to fire |
| + | * resistant to cell deterioration (non-corrosive) |
| + | * resistant to thermal cycling (dimensionally stable) |
| + | * stable K value (thermal conductivity does not change with age) |
| + | * conforms to substrate irregularities |
| + | * can be hot mopped or mechanically fastened |
| | | |
− | Field-tapered perlitic insulation board systems consist of multiple layers of square-edged perlite boards that are tapered by cutting or grinding in the field.
| + | The possible disadvantages or precautions involved in the use of mineral fibre roof insulation: |
| + | * heavy equipment may compress the insulation and cause delamination of the membrane |
| + | * not intended for use under high traffic deck surfaces |
| | | |
− | Factory-tapered insulation board systems are the ones most commonly used because they are inexpensive and easy to use. The insulation boards can be tapered to provide slopes of 1:200 (1/16" in 12") or greater. The following types of insulation are factory-tapered:
| + | Mineral fibre roof insulation should meet or exceed CAN / ULC S126.M86. |
− | * Extruded polystyrene
| + | <div id=3.2Composite> |
− | * Expanded polystyrene
| |
− | * Polyisocyanurate
| |
− | * Fibreboard
| |
| | | |
− | === Composite Board Insulation and Overlay Boards === | + | ===Composite Board Insulation=== |
| Composite board roof insulation products consist of an insulation bonded with another insulation and / or a variety of other products (typically fibreboard, perlite, membranes, etc.) to form a unified, multi-layered insulation board. The top and bottom surfaces of the board may be impregnated and / or coated with asphalt (or other binders), and covered with facing materials such as roofing felts, foils, kraft paper modified bituminous membranes, etc. | | Composite board roof insulation products consist of an insulation bonded with another insulation and / or a variety of other products (typically fibreboard, perlite, membranes, etc.) to form a unified, multi-layered insulation board. The top and bottom surfaces of the board may be impregnated and / or coated with asphalt (or other binders), and covered with facing materials such as roofing felts, foils, kraft paper modified bituminous membranes, etc. |
| | | |
Line 136: |
Line 165: |
| * Sometimes expensive, and | | * Sometimes expensive, and |
| * Limited availability | | * Limited availability |
| + | <div id=3.9Perlitic> |
| + | |
| + | ===Perlitic Insulation=== |
| + | Perlite ore is a volcanic glass with a natural water content characteristic. When this ore is heated to approximately +930<sup>o</sup>C (+1700<sup>o</sup>F) the water vaporizes and the ore expands into glass spheroids. The expanded perlite ore may be mixed into a water slurry formulation containing cellulose fibre, a small amount of asphalt, and sometimes starch. The slurry is then dried into boards and cut to size. The top surface is usually treated to minimize bitumen absorption. |
| + | |
| + | Perlitic roof insulation provides the following properties and advantages: |
| + | * Compatible with asphalt |
| + | * Compatible with most roof system components |
| + | * Resistant to thermal conductivity |
| + | * Resistant to fire |
| + | * Resistant to impact |
| + | * Resistant to thermal cycling (dimensionally stable) |
| + | * Unaffected by asphalt application temperatures |
| + | * Stable K-value |
| + | * Retains roofing nails |
| + | |
| + | The possible disadvantages or precautions involved in the use of perlitic roof insulation include: |
| + | * Absorbs moisture (protect from the effects of weathering) |
| + | * Heavy equipment may compress boards causing possible debonding of the insulation from the deck |
| + | * Extremely friable (crushable); proper compounding and correct grading is important |
| + | * Relatively low thermal values. |
| | | |
− | ==== <b><i>*Soprema Inc.</i></b> ==== | + | <div id=4.1Concrete> |
− | * Soprabase FR & Soprabase 180 FR - Fire Resistant Wood Fibreboard with Factory Applied Base Sheet
| |
− | * {{hilite | Xpress Board HD || 2015-October-20 }} - Non-Combustible Mineral Wool Insulation with Factory Applied Base Sheet .(See 3.7.3.6 for physical properties.)
| |
− | * XPRESS ISO Cover Board - Polyisocyanurate Insulation adhered to Mineral Wool Insulation with Factory Applied Base Sheet.
| |
− | * XPRESS EPS Cover Board - Expanded Polystyrene Insulation adhered to Mineral Wool Insulation with Factory Applied Base Sheet.
| |
| | | |
− | ==== <b><i>* Posi-Slope Western</i></b> ==== | + | ===Lightweight Insulating Concrete=== |
− | * MF - Protect Board Composite - Non-combustible mineral wool insulation with laminated asphalt core board.
| |
| | | |
− | === Glass Fibreboard (Fibreglass) === | + | <div id=3.3Glass> |
| + | |
| + | ===Glass Fibreboard (Fibreglass)=== |
| Glass fibreboard roof insulations are composed of fine glass fibres compressed into rigid insulation boards. These boards are most commonly available top-surfaced with a glass fibre-reinforced asphalt and kraft paper. This provides a suitable surface for directly mopped bituminous membranes and for some flexible membrane roof systems. In addition, boards made of glass fibres bound in a resinous binder are available either top-surfaced for bituminous roofing, or plain for use under ballasted membrane systems. | | Glass fibreboard roof insulations are composed of fine glass fibres compressed into rigid insulation boards. These boards are most commonly available top-surfaced with a glass fibre-reinforced asphalt and kraft paper. This provides a suitable surface for directly mopped bituminous membranes and for some flexible membrane roof systems. In addition, boards made of glass fibres bound in a resinous binder are available either top-surfaced for bituminous roofing, or plain for use under ballasted membrane systems. |
| | | |
Line 164: |
Line 211: |
| * Conforms to minor deck irregularities, and / or | | * Conforms to minor deck irregularities, and / or |
| * Retains roofing nails (first layer in a two-layer application only). | | * Retains roofing nails (first layer in a two-layer application only). |
| + | |
| | | |
| The possible disadvantages or precautions involved in the use of glass fibreboard insulation include: | | The possible disadvantages or precautions involved in the use of glass fibreboard insulation include: |
Line 172: |
Line 220: |
| Glass fibreboard roof insulation should meet or exceed CAN / CGSB-51.31-M84. | | Glass fibreboard roof insulation should meet or exceed CAN / CGSB-51.31-M84. |
| | | |
− | ==== <b><i>* TBA</i></b> ==== | + | ==Heat-sensitive Insulation== |
| + | <div id=3.4XPS> |
| | | |
− | === Extruded Expanded Polystyrene Foam === | + | ===XPS (Extruded Polystyrene Foam)=== |
− | (See also 3.6.6 <i>Expanded Polystyrene Foam</i> and 3.13 <i>Protected Membrane Roof Assemblies</i>) | + | :(See also [[Insulating the Roof#3.5Expanded |'''''Expanded Polystyrene Foam''''']] below, and [http://rpm.rcabc.org/index.php?title=Protected_and_Modified_Protected_Roof_Systems '''Protected and Modified Protected Roof Systems''']) |
| | | |
| Molten polystyrene and a blowing agent HCFC (142B) are mixed, under pressure, in an extruder. As this solution is extruded through an orifice into ambient temperature and controlled conditions, the blowing agent vapourizes causing the polystyrene to expand approximately 30 times its original size. The continuous extrusion process produces boards with a surface “skin” and closed cell structure and, for this reason, has been used extensively for protected membrane roof assemblies. The rigid insulation boards are expanded to a specific thickness during manufacture and have an approximate density of 32 kg / cu. m (2 lb / cu.ft). | | Molten polystyrene and a blowing agent HCFC (142B) are mixed, under pressure, in an extruder. As this solution is extruded through an orifice into ambient temperature and controlled conditions, the blowing agent vapourizes causing the polystyrene to expand approximately 30 times its original size. The continuous extrusion process produces boards with a surface “skin” and closed cell structure and, for this reason, has been used extensively for protected membrane roof assemblies. The rigid insulation boards are expanded to a specific thickness during manufacture and have an approximate density of 32 kg / cu. m (2 lb / cu.ft). |
Line 202: |
Line 251: |
| * Dimensional instability may result from improper curing at the factory | | * Dimensional instability may result from improper curing at the factory |
| | | |
− | <hr> | + | <div id=3.5Expanded> |
| | | |
− | ==== TECH-CRETE PROCESSORS LTD. ==== | + | ===EPS (Expanded Polystyrene Foam)=== |
| + | :(See also [[Insulating the Roof#3.4XPS |'''''Extruded Expanded Polystyrene Foam''''']]) |
| | | |
− | <i>Manufacturer:</i> <b>TECH-CRETE PROCESSORS LTD.</b>
| + | <i> Third Party Certification</i>: The RoofStar Guarantee Program welcomes and accepts the industry recommendation presented by all EPS manufacturers currently active in the B.C. market to require third party certification of the EPS products meeting CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) requirements. It is understood that such a certification program requires annual inspections / re-certification by an independent testing lab. |
− | | |
− | <i>Contact Address:</i> See Membership List Section 1
| |
− | | |
− | <i>Product Group:</i> <b>CONCRETE TOPPED INSULATION ROOF PANELS FOR USE IN PROTECTED MEMBRANE ROOF ASSEMBLIES</b>
| |
− | | |
− | <i>Country of Origin:</i> CANADA
| |
− | | |
− | <i>Country of Manufacture:</i> Canada, 1983
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b><i>RCABC Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | Tech-Crete™ insulated roof panels are 600 mm (2 ft. X 4 ft) composite panels of extruded, expanded, Type 4 CAN/ULC-S701-97 / CGSB-51.20-M87 polystyrene foam, with a factory applied 9.5mm (3/8”) latex modified concrete topping. They are designed as lightweight, self-ballasted, interlocking insulated panels for loose application on top of well drained roof membranes in a low-slope, protected membrane roof assembly.
| |
− | | |
− | Tech-Crete panels are tongue and grooved on the longitudinal sides, with a butt edge on the lateral ends. Each board weighs minimum 16.3 kg (36 lb.) creating an insulated panel assembly of about 22 kg/m² (4.5 lb/ft². Panels are available in standard thickness of 50 mm (2”) and 100 mm (4”). In addition, 75 mm (3”) thick panels are available as special order.
| |
− | | |
− | <u>BASE INSULATION</u>
| |
− | | |
− | The base insulation is Dow Roofmate*, a superior moisture resistant material (absorption less than 1%) with a high thermal resistance value of 0.88 (R 5.0 per inch.), and high compressive strength of 240 kPa (35 psi).
| |
− | | |
− | <u>CONCRETE TOPPING</u>
| |
− | | |
− | The latex modified concrete topping is available in two standard colours, both with a relatively smooth surface:
| |
− | * CTI (Concrete Topped) Insulated Roof Panels are manufactured as a standard concrete grey colour.
| |
− | * SRI (Solar Reflective) Insulated Roof Panels are manufactured with a full depth white concrete topping.
| |
− | | |
− | <u>PERFORMANCE</u>
| |
− | | |
− | Latex modified concrete is very durable and chemically resistant. It can be cut with a masonry saw.
| |
− | * Concrete topped insulation roof panels can accept occasional maintenance foot traffic, however, they are not intended for use as a patio, plaza deck or construction platform.
| |
− | * As with other cementitious products, concrete topped insulation roof panels can become stained by efflorescence if stored unprotected for extended periods. This efflorescence will not be so obvious on SRI panels, however, care in scheduling and handling is required to ensure the white topping remains clean.
| |
− | * Concrete topped insulation roof panels are compatible with most commonly used membranes, however, in some cases a slip sheet between membrane and insulation is required to minimize cracking of the concrete topping.
| |
− | | |
− | <u>CERTIFICATIONS AND APPROVALS</u>
| |
− | | |
− | Complies with the following codes:
| |
− | | |
− | * CCMC - Evaluation Listing #04888-L
| |
− | * CAN/ULC S107, Type 4 - standard for Thermal Insulation Polystyrene Boards.
| |
− | * CAN/ULC S107-03 Methods of Fire Tests of Roof Coverings
| |
− | | |
− | ™ Trademark of Tech-Crete Processors Ltd.
| |
− | *Trademark of the Dow Chemical Company
| |
− | | |
− | <hr>
| |
− | | |
− | ==== DOW CHEMICAL CANADA INC. ====
| |
− | | |
− | <i>Manufacturer:</i> <b>DOW CHEMICAL CANADA INC.</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List Section 1
| |
− | | |
− | <i>Product Group:</i> <b>EXTRUDED, EXPANDED POLYSTYRENE INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> United States
| |
− | | |
− | <i>Country of Manufacture:</i> Canada, United States, locations worldwide
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the<b> RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | <b>DECKMATE* (Type 2)</b>
| |
− | | |
− | DECKMATE insulation is specifically designed to provide high quality, economical insulation for all conventional roofs, with single-ply, 2-ply or 4-ply roof membranes.
| |
− | | |
− | DECKMATE roof insulation is an extruded, expanded Type 2 CAN / ULC-S701-97 / CAN / CGSB-51.20-M87 polystyrene foam. It has excellent insulating characteristics (RSI 0.87 per 25 mm (R 5.0 per inch) of thickness), good compressive strength (110 kPa or 16 psi), and low water absorption (less than 1%).
| |
− | | |
− | DECKMATE has a smooth, high-density skin, and a closed-cell foam structure with shiplap edges on four sides. It is uniform in thickness and consistency and is easy to cut and handle. When installing, DECKMATE can be either loosely applied or attached to the substrate with mechanical fasteners, hot asphalt or adhesive. Board size is 600 mm x 2400 mm (2' x 8'), in thickness ranging from 25 mm to 100 mm (1" to 4").
| |
− | | |
− | <b>DECKMATE* PLUS (Type 3)</b>
| |
− | | |
− | DECKMATE* PLUS insulation is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes.
| |
− | | |
− | DECKMATE* PLUS roof insulation is an extruded, expanded, Type 3 CAN / ULC S701 polystyrene foam. It has excellent insulating characteristics (RSI-.087 per 25 mm [R 5.0 per inch] of thickness), good compressive strength (140 kPa or 20 psi) and low water absorption (less than 1%).
| |
− | | |
− | DECKMATE* PLUS has a smooth, high-density skin, and a closed cell structure, with ship-lapped edges on four sides. It is uniform in thickness and consistency, and is easy to cut and handle. When installing, DECKMATE * PLUS can be either loose applied or attached to the substrate with mechanical fasteners, hot asphalt or adhesive. Board size is 600 mm x 2400 mm (2' x 8'), in thickness ranging from 25 mm - 100 mm (1" - 4").
| |
− | | |
− | <b>ROOFMATE* (Type 4)</b>
| |
− | | |
− | ROOFMATE insulation is an extruded, expanded, foamed Type 4 CAN / ULC-S701-97 / CAN / CGSB-51.20-M87 polystyrene rigid board designed specifically for roof applications. It is suitable for use in both protected membrane and conventional roof assemblies.
| |
− | | |
− | The extruded board has smooth, high-density skins, shiplap edges on four sides and a very dense closed-cell foam structure. Board size is 600 mm x 2400 mm (2' x 8'), in thickness ranging from 25 mm to 100 mm (1" to 4"). ROOFMATE has one of the highest thermal resistance values, an aged (RSI value of 0.87 per 25 mm (R 5.0 per inch). It has excellent water resistance characteristics (absorption of less than 1%) and a high compressive strength of 240 kPa (35 psi).
| |
− | | |
− | ROOFMATE is ideal for use in both standard and lightweight protected membrane roof systems and can be adhered or loosely applied. It is lightweight, easy to cut and simple to install year round.
| |
− | | |
− | <hr>
| |
− | | |
− | ==== OWENS CORNING CANADA INC. ====
| |
− | | |
− | <i>Manufacturer:</i> <b>OWENS CORNING CANADA INC.</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List Section 1
| |
− | | |
− | <i>Product Group:</i> <b>EXTRUDED, EXPANDED POLYSTYRENE INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> United States
| |
− | | |
− | <i>Country of Manufacture:</i> Canada, United States, locations worldwide
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the<b> RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | <b>FOAMULAR® C200 (Type 3)</b>
| |
− | | |
− | FOAMULAR® C200® insulation is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes.
| |
− | | |
− | FOAMULAR® C200® insulation is an extruded, Type 3 CAN / ULC S701 polystyrene foam. It has excellent insulating characteristics (RSI-.088 per 25 mm [R 5.0 per inch] of thickness), compressive strength (140 kPa or 20 psi) and low water absorption (less than 0.7%).
| |
− | | |
− | FOAMULAR® C200® has a smooth, high-density skin, and a closed cell structure, with ship-lapped or square edges on four sides. It is uniform in thickness and consistency, and is easy to cut and handle. When installing, FOAMULAR® C200® can be either loose applied or attached to the substrate with mechanical fasteners, hot asphalt or adhesive. Board size is 600 mm x 2400 mm (2' x 8'), in thickness ranging from 25 mm - 100 mm (1" - 4").
| |
− | | |
− | <b>FOAMULAR® F350 (Type 4)</b>
| |
− | | |
− | FOAMULAR® F350 insulation is an extruded, Type 4 CAN/ULC-S701/CAN/CGSB-51.20-M87 polystyrene rigid board designed specifically for roof applications. It is suitable for use in both protected membrane and conventional roof assemblies
| |
− | | |
− | The extruded board has smooth, high-density skins, shiplap edges on four sides and a very dense closed-cell foam structure. Board size is 600 mm x 1200 mm (2' x 4'), in thickness ranging from 25 mm to 100 mm (1" to 4"). FOAMULAR® F350 has one of the highest thermal resistance values, an aged (RSI value of 0.88 per 25 mm (R 5.0 per inch). It has excellent water resistance characteristics (absorption of less than 0.7%) and a high compressive strength of 240 kPa (35 psi).
| |
− | | |
− | FOAMULAR® F350 is ideal for use in both standard and lightweight protected membrane roof systems and can be adhered or loosely applied. It is lightweight, easy to cut and simple to install year round.
| |
− | | |
− | <b>FOAMULAR® F350 CVI (Type 4)</b>
| |
− | | |
− | FOAMULAR® F350 CVI insulation is an extruded, Type 4 CAN/ULC-S701/CAN/CGSB-51.20-M87 polystyrene rigid board designed specifically for roof applications. It is suitable for use in both protected membrane and conventional roof assemblies.
| |
− | | |
− | The extruded board has smooth, high-density skins, shiplap edges on four sides and a very dense closed-cell foam structure. Board size is 600 mm x 1200 mm (2' x 4'), in thickness ranging from 25 mm to 100 mm (1" to 4"). FOAMULAR® F350 CVI has one of the highest thermal resistance values, an aged (RSI value of 0.88 per 25mm (R 5.0 per inch). It has excellent water resistance characteristics (absorption of less than 0.7%) and a high compressive strength of 240 kPa (35psi).
| |
− | | |
− | Owens Corning developed the FOAMULAR® 350 CVI board with drainage channels on the underside and around the entire perimeter. Compared to the FOAMULAR® 350 board, the FOAMULAR® 350 CVI board has the additional advantage of facilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
| |
− | | |
− | FOAMULAR® F350 CVI is ideal for use in both standard and lightweight protected membrane roof systems and can be adhered or loosely applied. It is lightweight, easy to cut and simple to install year round.
| |
− | | |
− | <b>FOAMULAR® 400/600/1000 (Type 4)</b>
| |
− | | |
− | FOAMULAR® 400/600/1000 insulation is an extruded Type 4 CAN/ULC-S701-CAN/CGSB-51.20-M87 polystyrene rigid board insulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes.
| |
− | | |
− | The extruded board has smooth, high-density skins, shiplap or Square edges on four sides and a very dense closed-cell foam sturcture. Board size is 600 mm x 1200 mm (2'x 8'), in thickness ranging from 25 mm to 100 mm (1" to 4"). FOAMULAR® 400/600/1000 has one of the highest thermal resistance values, an aged (RSI value of 0.88 per 25 mm (R5.0 per inch). It has excellent water resistance characteristics (absorption of less than 0.7%) and a high compressive strength of 275 kPa, 415 KPa, 690 KPa (40 psi, 60 psi, and 100 psi).
| |
− | | |
− | FOAMULAR® 400/600/1000 is ideal for use in both standard and lightweight protected membrane roof systems and can be adhered or loosely applied. It is lightweight, easy to cut and simple to install year round.
| |
− | | |
− | <b>FOAMULAR® 404/604 and FOAMULAR® 404 RB/604 RB (Type 4)</b>
| |
− | | |
− | FOAMULAR® 404/604 and FOAMULAR® 404 RB/604 RB insulation is an extruded Type 4 CAN/ULC-S701-CAN/CGSB-51.20-M87 polystyrene rigid board insulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes.
| |
− | | |
− | The extruded board has smooth, high-density skins, shiplap or Square edges on four sides and a very dense closed-cell foam structure. Board size is 600 mm x 1200 mm (2' x 8'), in thickness ranging from 38 mm to 76 mm (1.5" to 3"). FOAMULAR® 404/604 and FOAMULAR® 404 RB/604 RB has one of the highest thermal resistance values, an aged (RSI value of 0.88 per 25 mm (R 5.0 per inch) for the FOAMULAR® 404/604 and (RSI value of 0.84 per 25 mm (R 4.75 per inch) for the FOAMULAR® 404 RB/604 RB. It has excellent water resistance characteristics (absorption of than 0.05%) and a high compressive strength of 275 kPa, 415 KPa, 690 KPa (40 psi, 60 psi and 100 psi).
| |
− | | |
− | Owens Corning developed the FOAMULAR® 404/604 boards with drainage channels around the board perimeter. Compared to a FOAMULAR® 400/600 board, the FOAMULAR® 404/604 board has the additional advantage of facilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
| |
− | | |
− | The FOAMULAR® 404 RB/604 RB boards have as the additional feature of top side channels that help facilitate the flow of water to the system's drains.
| |
− | | |
− | FOAMULAR® 404/604 and FOAMULAR® 404 RB/604 RB is ideal for use in both standard and lightweight protected membrane roof systems and can be adhered or loosely applied. It is lightweight, easy to cut and simple to install year round.
| |
− | | |
− | === Expanded Polystyrene Foam ===
| |
− | (See also 3.6.5 <i>Expanded Extruded Polystyrene</i>)
| |
− | | |
− | <i> Third Party Certification</i>: RGC welcomes and accepts the industry recommendation presented by all EPS manufacturers currently active in the B.C. market to require third party certification of the EPS products meeting CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) requirements. It is understood that such a certification program requires annual inspections / recertification by an independent testing lab. | |
| | | |
| Molten polystyrene and a blowing agent are mixed and formed into uniform closed-cell structures (“beads”). These are later expanded up to 40 times by steam in a pre-expander. (The amount of expansion determines the density and, therefore, the thermal conductivity of the final product.) The expanded beads are stabilized in curing bins, fused into a billet in a block mold, and cut into the desired size, shape and thickness. This process produces rigid boards of interconnecting closed cells of densities varying from 16 to 48 kg / cu.m (1 to 3 lb / cu.ft). Expanded polystyrene insulation is commonly referred to as “beadboard” or “popcorn”. | | Molten polystyrene and a blowing agent are mixed and formed into uniform closed-cell structures (“beads”). These are later expanded up to 40 times by steam in a pre-expander. (The amount of expansion determines the density and, therefore, the thermal conductivity of the final product.) The expanded beads are stabilized in curing bins, fused into a billet in a block mold, and cut into the desired size, shape and thickness. This process produces rigid boards of interconnecting closed cells of densities varying from 16 to 48 kg / cu.m (1 to 3 lb / cu.ft). Expanded polystyrene insulation is commonly referred to as “beadboard” or “popcorn”. |
| | | |
− | Expanded polystyrene roof insulation is presently manufactured to the CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) standard and is available in four types, depending on the physical properties of the material. Basically, the strength (tensile, compressive, flexural, and shear) and thermal resistance properties increase, and the water vapour permeance and water absorption properties decrease from Type 1 to Type 4. (For Type 2 and Type 4 see also Section 3.6.5 <i>Extruded Expanded Polystyrene</i>). <b>Note:</b> Type 4 is usually, if not always, extruded. | + | Expanded polystyrene roof insulation is presently manufactured to the CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) standard and is available in four types, depending on the physical properties of the material. Basically, the strength (tensile, compressive, flexural, and shear) and thermal resistance properties increase, and the water vapour permeance and water absorption properties decrease from Type 1 to Type 4. (For Type 2 and Type 4 see also section 6 above, <i>Extruded Expanded Polystyrene</i>). <b>Note:</b> Type 4 is usually, if not always, extruded. |
| | | |
− | Expanded polystyrene foam roof insulation is combustible and, when used on steel decks or over a roof that is subject to fire exposure from below, a fire-rated underlayment or thermal barrier (such as gypsum board) may be required between the roof deck and the insulation (consult Building Code and insurance requirements). | + | Expanded polystyrene foam roof insulation is combustible and, when used on steel decks or over a roof that is subject to fire exposure from below, a fire-rated underlayment or thermal barrier (such as gypsum board) may be required between the roof deck and the insulation (consult local building bylaws and the latest edition of the BC Building Code, together with insurance requirements). |
| | | |
| Expanded polystyrene foam roof insulation provides the following properties and advantages: | | Expanded polystyrene foam roof insulation provides the following properties and advantages: |
Line 384: |
Line 279: |
| * Dimensional instability may result from improper curing at the factory. | | * Dimensional instability may result from improper curing at the factory. |
| | | |
− | <hr> | + | <div id=3.6Polyurethane> |
| | | |
− | ==== MANSONVILLE PLASTICS (B.C.) LTD. ==== | + | ===Polyurethane Foam=== |
| + | {{Template:Insulation (Polyurethane)}} |
| + | <div id=3.1Tapered> |
| | | |
− | <i>Manufacturer:</i> <b>MANSONVILLE PLASTICS (B.C.) LTD.</b>
| + | ==Tapered Insulation== |
| + | Tapered roof insulation systems are generally available in three forms: |
| + | * Field-sloped lightweight insulating concrete roof fill |
| + | * Field-tapered perlitic insulation boards |
| + | * Factory-tapered insulation boards |
| | | |
− | <i>Contact Address: See Membership List, Section 1</i>
| + | For a discussion of field-sloped lightweight insulating concrete roof fill systems see the Section entitled [[Roof Decks|'''Roof Decks''']]. |
| | | |
− | <i>Product Group:</i> <b>EXPANDED POLYSTYRENE INSULATION</b>
| + | Field-tapered perlitic insulation board systems consist of multiple layers of square-edged perlite boards that are tapered by cutting or grinding in the field. |
| | | |
− | <i>Country of Origin:</i> Canada
| + | Factory-tapered insulation board systems are the ones most commonly used because they are inexpensive and easy to use. The insulation boards can be tapered to provide slopes of 1:200 (1/16" in 12") or greater. The following types of insulation are factory-tapered: |
− | | + | * Polyisocyanurate |
− | <i>Country of Manufacture:</i> Canada
| + | * Mineral wool |
− | | + | * XPS |
− | <u>DESCRIPTION</u>
| + | * EPS |
− | | + | * Fibreboard |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | Korolite and Koroslope expanded polystyrene (EPS) manufactured by Mansonville Plastics (B.C.) Ltd. are rigid roof insulations, suitable for a variety of roof systems, supplied in both flat and sloped profiles. These insulations are closed cell, light weight and, because of their unique cellular structure, assure permanent thermal values.
| |
− | | |
− | They are 100% free of ozone depleting CFC’s and HCFC’s and can be recycled.
| |
− | | |
− | <u>KOROLITE REGULAR INSULATION</u>
| |
− | | |
− | This EPS flat insulation is the most popular insulation and provides the best value for thermal resistance in most roofing applications.
| |
− | | |
− | <table border=1 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance :</td>
| |
− | <td colspan=3>RSI = 0.65 / 25 mm (R Value = 3.75 / in.)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td>
| |
− | <td colspan=3>All conventional roofs for single ply, 2 ply modified and built up roof membranes.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards:</td>
| |
− | <td colspan=3>Conforms to CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) Type 1 thermal insulation expanded polystyrene.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td valign=top>Standard Sizes:</td>
| |
− | <td align=center>0.6 m x 1.2 m<br>(24" x 48")</td>
| |
− | <td align=center>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td align=center>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=3>Any thickness that is required to meet thermal requirements.</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>KOROLITE HD INSULATION</u>
| |
− | | |
− | This EPS flat insulation is used when the roof design dictates the need for a greater compressive and thermal value.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance :</td><td colspan=3>RSI = 0.70 / 25 mm (R Value = 4.0 / in.)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td><td colspan=3>All conventional roofs for single ply, 2 ply modified and built up roof membranes; providing a higher thermal and compressive strength than Korolite Regular Insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards:</td><td colspan=3>Conforms to CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) Type 2 thermal insulation expanded polystyrene.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td valign=top>Standard Sizes:</td>
| |
− | <td align=center>0.6 m x 1.2 m<br>(24" x 48")</td>
| |
− | <td align=center>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td align=center>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=3>Any thickness that is required to meet thermal requirements.</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>KOROSLOPE TAPERED INSULATION</u>
| |
− | | |
− | Koroslope is a modular tapered insulation roof system designed to provide positive drainage of water on flat roofs.
| |
− | | |
− | * Custom computerized design and roof layout drawings are provided.
| |
− | * The most commonly used slopes are 1:100 (1/8" in 12") and 1:50 (1/4" in 12")
| |
− | * Can be supplied in Type 1 or Type 2
| |
− | * Thermal Resistance: same as flat Type 1 or 2 per inch or mm of thickness
| |
− | * Meets the same CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87) Type 1 and 2 specification
| |
− | | |
− | Uses:
| |
− | * To add slope to all conventional roofs for single ply, 2 ply, and built up roof membranes
| |
− | * Crickets and backslope to direct water away from walls and projections and to provide slope in valleys, can also be supplied.
| |
− | | |
− | Standard Sizes: 1.2 m x 1.2 m (48" x 48")
| |
− | | |
− | <hr>
| |
− | | |
− | ==== PLASTI-FAB, division of PFB Corporation ====
| |
− | | |
− | <i>Manufacturer:</i> <b>PLASTI-FAB, division of PFB Corporation</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List in Section 1.
| |
− | | |
− | <i>Product Group:</i> <b>EXPANDED POLYSTYRENE INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> Canada
| |
− | | |
− | <i>Country of Manufacture:</i> Canada
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | The Plasti-Fab™ PlastiSpan® trademark is applied to a series of moulded expanded polystyrene insulations (EPS) insulation materials manufactured by Plasti-Fab. These insulation materials are lightweight, easy to handle rigid thermal insulation materials. The closed cell structure of PlastiSpan insulation materials does not contain a captive blowing agent - e.g. HCFC’s - and assures constant thermal resistance properties. PlastiSpan insulation is manufactured in a range of densities and forms for use as a component in roofing assemblies.
| |
− | | |
− | <u>PLASTISPAN INSULATION (TYPE 1)</u>
| |
− | | |
− | PlastiSpan insulation identifies the most widely used PlastiSpan insulation in the family with a nominal density of 16 kg / m<sup>3 </sup>(1.0 lb / ft<sup>3</sup>). It provides the best thermal resistance value in most roofing applications.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td colspan=2>RSI = 0.65 m<sup>2</sup>•<sup>O</sup>C / (W•25 mm)/R Value = 3.75 Ft <sup>2</sup>•hr•<sup> O</sup>F/(BTU•in)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Compressive Resistance @ 10% Deformation: 70 kPa / 10 psi</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td>
| |
− | <td colspan=2>•Any conventional roofs with single-ply, two-ply or four-ply membranes where EPS insulation is permitted.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Under shingles (for cathedral ceilings).</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards:</td>
| |
− | <td colspan=2>• Conforms to CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87), Type 1 expanded polystyrene thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Meets Building Code requirements for foamed plastic thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• CCMC Evaluation Listing 12424-L.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes:</td>
| |
− | <td>0.6 m x 1.2 m (24" x 48")</td>
| |
− | <td>0.6 m x 2.4 m (24" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>0.8 m x 1.2 m (32" x 48")</td>
| |
− | <td>1.2 m x 2.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td>1.2 m x 1.2 m (48" x 48")</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Any thickness to meet thermal requirements.</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>PLASTISPAN HD INSULATION (TYPE 2)</u>
| |
− | | |
− | PlastiSpan HD insulation identifies a thermal insulation with a normal density approximately 50% higher than PlastiSpan insulation (Type 1) at 24 kg / m<sup>3</sup> (1.5 lb / ft<sup>3</sup>).
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td colspan=2>RSI = 0.70 m<sup>2</sup>•<sup>O</sup>C / (W•25 mm)/R Value = 4.04 Ft <sup>2</sup>•hr•<sup> O</sup>F / (BTU•in)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Compressive Resistance @ 10% Deformation: 110kPa / 16 psi</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td>
| |
− | <td colspan=2>•Any conventional roofs with single-ply, two-ply or four-ply membranes where EPS insulation is permitted.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Under shingles (for cathedral ceilings).</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Used in any roofing applications in which heavier roof loads require a higher compressive strength than PlastiSpan insulation (Type 1).</td>
| |
− | <tr>
| |
− | <td>Standards:</td>
| |
− | <td colspan=2>• Conforms to CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87), Type 2 expanded polystyrene thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Meets Building Code requirements for foamed plastic thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• CCMC Evaluation Listing 12425-L.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes:</td>
| |
− | <td>0.6 m x 1.2 m (24" x 48")</td>
| |
− | <td>0.6 m x 2.4 m (24" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>0.8 m x 1.2 m (32" x 48")</td>
| |
− | <td>1.2 m x 2.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td>1.2 m x 1.2 m (48" x 48")</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Any thickness to meet thermal requirements.</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>PLASTISPAN INSULATION (TYPE 3)</u>
| |
− | | |
− | PlastiSpan insulation (Type 3) identifies a thermal insulation with a nominal density approximately 100% higher than PlastiSpan insulation (Type 1) at 32 kg / m<sup>3</sup> (2.0 lb / ft<sup>3</sup>).
| |
− | | |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td colspan=2>RSI = 0.74 m2•OC / (W•25 mm) / R Value = 4.27 Ft 2•hr• OF / (BTU•in)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Compressive Resistance @ 10% Deformation: 140kPa / 20 psi</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td>
| |
− | <td colspan=2>•Any conventional roofs with single-ply, two-ply or four-ply membranes where EPS insulation is permitted.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Under shingles (for cathedral ceilings).</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Used in any roofing applications in which heavier roof loads require a higher compressive strength than PlastiSpan insulation (Type 1) or PlastiSpan HD insulation (Type 2).</td>
| |
− | <tr>
| |
− | <td>Standards:</td>
| |
− | <td colspan=2>• Conforms to CAN / ULC-S701-97 / (CAN / CGSB-51.20-M87), Type 3 expanded polystyrene thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• Meets Building Code requirements for foamed plastic thermal insulation.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>• CCMC Evaluation Listing 12426-L.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes:</td>
| |
− | <td>0.6 m x 1.2 m (24" x 48")</td>
| |
− | <td>0.6 m x 2.4 m (24" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>0.8 m x 1.2 m (32" x 48")</td>
| |
− | <td>1.2 m x 2.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td>1.2 m x 1.2 m (48" x 48")</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></tD>
| |
− | <td colspan=2>Any thickness to meet thermal requirements.</td>
| |
− | <td></td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>PLASTISPAN SLOPED INSULATION</u>
| |
− | | |
− | The complete family of PlastiSpan insulation materials is available in both flat and sloped profiles. All roofing experts agree that adding a slope to the top surface of the roof assembly, however small, will provide positive drainage, eliminate pooled water, and can extend the life of the roof assembly. For sloped roofs, Plasti-Fab provides PlastiSpan insulation cut with a taper across the 1.2-rn (48") width. A predetermined layout of the tapered insulation boards is provided by Plasti-Fab in order to include a 1:50 (1/4" in 12") or 1:100 (1/8" in 12") positive slope to the drains. | |
− | | |
− | Special sizes, “crickets”, and back slopes are available; custom computerized design of PlastiSpan sloped insulation boards layout is provided.
| |
− | | |
− | === Polyurethane Foam ===
| |
− | Polyurethane foam is the result of a chemical reaction between two liquids, isocyanate and polyols, in combination with additives and catalytic agents. The mixture begins to foam instantly and quickly expands to approximately 30 times its original volume. The foam hardens into an airtight mass, becoming tack-free in minutes.
| |
− | | |
− | The insulating properties of the foam are derived from fluorocarbon vapour trapped in the foam's cells. Polyurethane roof insulation boards are generally available in either:
| |
− | * flat sheets of varying size and thickness that have been cut from large buns (or billets)
| |
− | * surfaced boards where the polyurethane is foamed between two skins (felt, aluminum foil, etc.) which become an integral part of the product.
| |
− | | |
− | Polyurethane foam roof insulation is combustible and, when used on steel decks or over a roof that is subject to fire exposure from below, a fire-rated underlayment or thermal barrier (such as gypsum board) should be installed between the roof deck and the insulation.
| |
− | | |
− | Polyurethane foam roof insulation is presently manufactured to two standards:
| |
− | | |
− | CGSB 51-GP-21M applies to unfaced polyurethane rigid insulation boards intended for applications where the continuous use surface temperature does not exceed +80°C (+176°F). This standard establishes three types (Type 1, 2 and 3) and three classes (Class 1, 2 or 3) of polyurethane insulation. The type is determined by the physical properties of the material and the class is determined by its surface burning characteristics.
| |
− | | |
− | CAN / CGSB-51.26-M86 applies to faced polyurethane rigid insulation boards intended for applications where the continuous use temperature is within -60°C to +80°C (-76°F to +176°F). This standard establishes four types (Type 1, 2, 3, or 4), four facing categories (Facing 1, 2, 3, or 4), and two surface burning characteristic classifications (surface burning characteristic “a” or “b”). The type is determined by the physical properties of the foam, the “facing” is determined by the product the polyurethane is foamed between, and the surface burning characteristic is derived from the final product's flame spread classification.
| |
− | | |
− | Polyurethane insulation provides the following properties and advantages:
| |
− | | |
− | * Compatible with asphalt
| |
− | * Compatible with roof system components
| |
− | * Resistant to the effects of moisture
| |
− | * Resistant to cell deterioration
| |
− | * Resistant to impact
| |
− | * Resistant to thermal conductivity
| |
− | * Unaffected by asphalt application temperatures.
| |
− | | |
− | The possible disadvantages or precautions involved in the use of polyurethane foam insulation include:
| |
− | * Flammable (combustible)
| |
− | * Requires an insulation overlay (fibreboard, vented base sheet, etc.) to prevent potential asphalt blistering
| |
− | * Aged thermal resistance should be used for design calculations
| |
− | * Felt skin may change dimensionally if exposed to weathering (provide protection prior to installation)
| |
− | * Heavy equipment may compress insulation, causing deflections in the deck and debonding of the insulation
| |
− | * Will not retain nails (requires screws and plates)
| |
− | | |
− | === Polyisocyanurate Foam ===
| |
− | Polyisocyanurate is a closed-cell rigid foam material. The insulation boards are manufactured with asphalt-saturated felt, glass fibre or acrylic facer sheets on the top or bottom of the foam core. In some cases the foam core is reinforced with glass fibre or acrylic to provide additional fire resistance and greater dimensional stability.
| |
− | | |
− | Polyisocyanurate foamboard roof insulation is presently manufactured to two standards:
| |
− | | |
− | * <u>CAN / ULC S704-01 (CGSB 51-GP-21M)</u> applies to unfaced polyisocyanurate rigid insulation boards intended for applications where the continuous use surface temperature does not exceed +110°C (+230°F). This standard establishes one type (Type 4) and three classes (Class 1, 2 or 3) of polyisocyanurate insulation. The type is determined by the physical properties of the material and the class is determined by its surface burning characteristics.
| |
− | | |
− | * <u>CAN / ULC S704-01 (CAN / CGSB-51.26-M86)</u> applies to faced polyisocyanurate rigid insulation boards intended for applications where the continuous use temperature is within -60°C to +80°C (-76°F to +176°F). This standard establishes four types (Type 1, 2, 3, or 4), four facing categories (Facing 1, 2, 3, or 4), and two surface burning characteristic classifications (surface burning characteristic “a” or “b”). The type is determined by the physical properties of the material, the facing is determined by the product the insulation is foamed between, and the surface burning characteristic is derived from the final product's flame spread classification. <i>RGC Guarantee Standards</i> require that polyisocyanurate insulation manufacturers clearly identify the manufacturing date on product labels.
| |
− | | |
− | Polyisocyanurate insulation provides the following properties and advantages:
| |
− | * Compatible with asphalt
| |
− | * Compatible with roof system components
| |
− | * Resistant to the effects of moisture
| |
− | * Resistant to cell deterioration
| |
− | * Resistant to impact
| |
− | * Resistant to thermal conductivity
| |
− | * Resistant to fire
| |
− | * Resistant to thermal cycling (dimensionally stable)
| |
− | * Unaffected by hot asphalt
| |
− | * Retains mechanical fasteners
| |
− | | |
− | The possible disadvantages or precautions involved in the use of polyisocyanurate foam insulation include:
| |
− | * Requires an insulation overlay (fibreboard or retrofit board) to prevent potential asphalt blistering
| |
− | * Aged thermal resistance Long Term Thermal Resistance (LTTR) tested to CAN / ULC -S770 should be used for design calculations. Refer to RPM Section 3.6.1.1 quick reference chart for thermal resistance values.
| |
− | * Felt skin may change dimensionally if exposed to weathering (provide protection prior to installation)
| |
− | * Heavy equipment may compress insulation, causing deflections and de-bonding of the membrane
| |
− | * Will not retain nails (requires screws and plates)
| |
− | | |
− | <hr>
| |
− | | |
− | ==== SOPREMA INC. ====
| |
− | | |
− | <i>Manufacturer:</i> <b>SOPREMA INC.</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>POLYISOCYANURATE ROOF INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | {{hilite | Sopra-Iso Plus || 2015-October-28 }} cores are state-of-the-art, closed-cell polyisocyanurate foam produced through the use of environmentally safe procedures. Polyisocyanurate, the most widely used and accepted foam insulation product in use today, provides superior fire performance characteristics and the ability to retain high R-Values. Designed for use in commercial roof applications. {{hilite | Sopra-Iso Plus || 2015-October-28 }} is available in 25 mm (1"), 37 mm (1.5"), and 50 mm (2") thicknesses. Sopraiso A is manufactured for exceptional strength, using dimensionally stable facers to add toughness to the boards and meet high quality standards.
| |
− | | |
− | <u>{{hilite | SOPRA-ISO PLUS || 2015-October-20 }}</u>
| |
− | | |
− | Polyisocyanurate core integrally laminated to a specially coated facer.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25mm (1")]></td>
| |
− | </tr>
| |
− |
| |
− | <tr>
| |
− | <td>Foam Density:</td>
| |
− | <td>32 kg / cu.m (2.0 lb / cu ft.)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength</td>
| |
− | <td>138 kpa (20 psi)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>Do not use with hot applied membranes, i.e. coal tar or asphalt</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Conforms to CAN / ULC S704-01 / CAN/ CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>FM-Class 1, I-60, I-90</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>UL C S-126</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m (48" x 48") for Asphalt or adhesive applied applications</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>1.2 m x 2.4 m (48" x 96") for Mechanically fastened applications</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <hr>
| |
− | | |
− | ==== RMAX, INC. ====
| |
− | | |
− | <i>Manufacturer:</i> <b>RMAX, INC.</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List in Section 1.
| |
− | | |
− | <i>Product Group:</i> <b>POLYISOCYANURATE INSULATION</b>
| |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RGC<i> Roofing Practices Manual</i></b> does NOT represent the complete set of the manufacturer's published data, nor does it represent a detailed specification. Information as available will be provided by Rmax to assist the design professional in his decision process.
| |
− | | |
− | Rmax offers a wide variety of roofing insulation products to meet almost every roofing insulation need. Featuring polyisocyanurate foam cores, these products are compatible with the complete range of today’s most popular roofing membranes.
| |
− | | |
− | <u>MULTI-MAX FA-3:</u>
| |
− | | |
− | Rmax Multi-Max FA is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber on each side. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof, modified bitumen or single-ply membranes and metal panel roofing systems. Multi-Max FA is intended for use in new roofing construction and limited retrofit / recover roofing constructions over steel, wood, non-combustible and certain types of nailable roof decks.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2>All conventional single-ply, modified and built-up roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Underwriters Laboratories of Canada (ULC) listed as to an external fire exposure only. (ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2m<br>(48" x 48")</td>
| |
− | <td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | <td colspan=2>Thicknesses: 38 mm to 101 mm (1.5" to 4.0")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>MULTI-MAX-3:</u>
| |
− | | |
− | Rmax Multi-Max is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber mat facers on each side. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof, modified bitumen or single-ply membranes and metal panel roofing systems. Multi-Max is intended for use in new roofing construction and limited retrofit / recover roofing constructions over steel, wood, non-combustible and certain types of nailable roof decks.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2>All conventional single-ply, modified and built-up roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Underwriters Laboratories of Canada (ULC) listed as to an external fire exposure only. (ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses: 38 mm to 102 mm (1.5" to 4.0")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>TAPERED THERMAROOF-3: </u>
| |
− | | |
− | Rmax Tapered Thermaroof is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber facers on each side. The top surface is manufactured with a 1/8", ¼", or ½" per foot slope to provide positive roof drainage. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof, modified bitumen or single-ply membranes. Tapered Thermaroof is intended for use in new roofing construction and limited retrofit / recover roofing constructions over steel, wood, non-combustible and certain types of nailable roof decks.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>All conventional single-ply, modified and built-up roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Underwriters Laboratories of Canada (ULC) listed as to an external fire exposure only. (ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m (48" x 48")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Thicknesses: 19 mm to 89 mm (0.75" to 3.5") with slopes of 1/8", ¼" and ½" per foot. See Rmax data sheets for specific panel dimensions.</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>RE-COVER BOARD-3:</u>
| |
− | | |
− | Rmax Re-Cover Board is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber / or glass fiber facers on each side. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof, modified bitumen or single-ply membranes and metal panel roofing systems. Re-Cover Board may be used in recover type applications where the existing roof system is still sound and firmly attached.
| |
− | | |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>Recover applications where the existing roof is still sound and firmly attached.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Manufactured to conform to CAN/ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction. FM listing requires that old roof is left in place and conforms to FM4450.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Thicknesses: 13 mm to 33 mm (0.5" to 1.3")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>THERMAROOF PLUS-3:</u>
| |
− | | |
− | Rmax Thermaroof Plus, with the reinforced aluminium foil facers, is an excellent insulation product for use with the loose-laid or mechanically fastened types of single ply membranes or metal panel roofing systems available today. Thermaroof Plus is approved for use in new roofing constructions, and limited retrofit / recover roofing projects over steel, wood, non-combustible and certain types of nailable surfaces.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>Loose laid or mechanically attached single ply membranes or metal panel roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Underwriters Laboratories of Canada (ULC) listed as to an external fire exposure only. (ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 2.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Thicknesses: 38 mm to 102 mm (1.5" to 4.0")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>THERMAROOF COMPOSITE-3:</u>
| |
− | | |
− | Rmax Thermaroof Composite is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber mat facers on one side and a ½" perlite board on the other. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof or modified bitumen roofing systems. Thermaroof Composite is intended for use in new roofing constructions, and limited retrofit / recover roofing constructions over steel, wood, non-combustible and certain types of nailable surfaces.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td colspan=2>RSI value = 0.88 / 25 mm (1") [R Value = 5.1 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2>All conventional modified and built-up roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Underwriters Laboratories of Canada (ULC) listed as to an external fire exposure only. (ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses: 38 mm to 102 mm (1.5" to 4.0")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>RDECK-3:</u>
| |
− | | |
− | Rmax Rdeck is a rigid, foam plastic, thermal insulation board composed of polyisocyanurate foam bonded to glass fiber facer on one side and a 1/4" board on the other. This roofing insulation is suitable for use in insulated roofing system constructions utilizing built-up roof or modified bitumen roofing systems. Rdeck is intended for use in new roofing constructions, and limited retrofit / recover roofing constructions over steel, wood, non-combustible and certain types of nailable surfaces.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td colspan=2>RSI value = 0.93 / 25 mm (1") [R Value = 5.4 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2>All conventional modified, built-up, single-ply membrane and metal panel roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Manufactured to conform to CAN / ULC-S704-01/ CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses: 38 mm to 102 mm (1.5" to 4.0")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>NAILABLE BASE-3:</u>
| |
− | | |
− | Rmax Nailable Base is a highly efficient thermal insulation board composed of a rigid closed cell polyisocyanurate foam core bonded to a 7/16" CDX Plywood or OSB nailing panel on the top surface and a glass fiber / organic mat facer on the other side. Rmax Nailable Base is for use with concrete, slate, or clay roofing tiles. It may also be used with wood shakes and metal panel roofing systems.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td>RSI value = 0.80 / 25 mm (1") [R Value = 4.66 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>Clay, slate or concrete roofing tile systems; wood shakes and metal panel roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Manufactured to conform to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Factory Mutual (FM) 4450 Class 1 approval for insulated steel deck construction</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Thicknesses: 38 mm to 115 mm (1.5" to 4.5")</td>
| |
− | </tr>
| |
− | </table>
| |
− |
| |
− | <u>VENTED NAILABLE BASE-3:</u>
| |
− | | |
− | Rmax Vented Nailable Base is a composite product made up of a CDX Plywood or OSB nailing surface, furring strips to produce ¾" or greater ventilating space, and a rigid polyisocyanurate foam core. Vented Nailable Base is for use in residential or commercial shingle roofing applications.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance:</td>
| |
− | <td>RSI value = 0.49 / 25 mm (1") [R Value = 2.86 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>Residential or commercial shingle applications.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td>Manufactured to conform to CAN/ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.4 m (48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>Thicknesses: 56 mm to 132 mm (2.2" to 5.2")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <hr>
| |
− | | |
− | ==== FIRESTONE BUILDING PRODUCTS COMPANY CANADA ====
| |
− | | |
− | <i>Manufacturer:</i> <b>FIRESTONE BUILDING PRODUCTS COMPANY CANADA</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>POLYISOCYANURATE ROOF INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | <u>FIRESTONE RESISTA</u>
| |
− | | |
− | Firestone RESISTA roof insulation consists of a closed-cell polyisocyanurate foam core laminated to a specially coated, inorganic, fibreglass facer. It provides outstanding fire, wind and thermal performance for commercial roofing applications. It can be used with all Firestone Roofing Systems Membrane.
| |
− | | |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Factory Mutual (FM) approved for Class I insulated steel deck construction (tested to FM 4450 standard)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Foamed plastic for built-up roof covering classified by Underwriters Laboratories of Canada (ULC) as to an external fire exposure only (per ULC S107)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Foamed plastic classified by Underwriters Laboratories of Canada as roof deck construction material with resistance to internal fire exposure for use in Construction No. C8 (tested to CAN / ULC-S126M)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Foamed plastic classified by Underwriters Laboratories of Canada for Fire Resistance Classification (tested to CAN / ULC-S101-M89). See ULC List of Equipment and Material Directory (Vol. III).</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Based on current UL, ULC and / or FM test data, Firestone Resista complies with the following model building codes when installed in accordance with UL, ULC and / or FM requirements: BOCA, ICBO, SBCCI, Metro-Dade 92-0930.02 and CAN/ULC- S704-01/ CAN / CGSB 51.26-M86. </td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Resista is mold resistant as per ASTM D3273 standards.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(4' x 4')</td>
| |
− | <td>1.2 m x 2.4 m<br>(4' x 8')</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses: 25.4 mm to 101.6 mm (1" to 4")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>FIRESTONE RESISTA TAPERED ROOF INSULATIONS</u>
| |
− | | |
− | Firestone Tapered Project Management Team offers the architect, consultant and general contractor complete engineered roof design support services.
| |
− | <table>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(4' x 4')</td>
| |
− | <td>1.2 m x 2.4 m<br>(4' x 8')</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td colspan=3>at standard slopes ranging 1/16" per foot (.5%) to 1/2" per foot (4%)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td colspan=3>Boards with slopes of 4.8 mm (3/16") and 9.5 mm (3/8") may be special ordered.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td colspan=3>Board thickness ranges from 12.7 mm to 63.5 mm (.5" to 2.5") maximum in one layer.</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <hr>
| |
− | | |
− | ==== JOHNS MANVILLE CORPORATION ====
| |
− | | |
− | <i>Manufacturer:</i> <b>JOHNS MANVILLE CORPORATION</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List in Section 1.
| |
− | | |
− | <i>Product Group:</i> <b>POLYISOCYANURATE ROOF INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the<b> RCABC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer's data. Detailed specification and design assistance is available through the distribution network, our representatives and the manufacturer. The preparation of the final detailed specification for the specific project is the responsibility of the architect / specifier.
| |
− | | |
− | Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies.
| |
− | | |
− | These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation.
| |
− | | |
− | <u>ENRGY 3 AGF & BARRIER BOARD ISO INSULATION</u>
| |
− | | |
− | ENRGY 3 AGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength</td>
| |
− | <td colspan=2>138 kpa nom (173 kpa available) [20 lb / sq. in nom (25 lb / sq. in available)]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2> All conventional single-ply, modified and built-up roofing systems.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Conforms to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86 (Types 1-4)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>FM-Class 1, I-60, I-90</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>ULC S-126</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(4' x 4')</td>
| |
− | <td>1.2 m x 2.4 m<br>(4' x 8')</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses: 25 mm to 104 mm (1" to 4.1")</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>TAPERED ENRGY 3 AGF INSULATION</u>
| |
− | | |
− | Johns Manville Corporation designs and manufactures tapered polyisocyanurate roof insulation systems, with slopes ranging from 1:200 (1/16" in 12") to 1:25 (1/2" in 12"). The most commonly used slopes are 1:100 (1/8" in 12") and 1:50 (1/4" in 12"). Complimentary computerized design service, as well as the normal “shop drawings” required for application, are available to the architect / specifier from Johns Manville Corporation.
| |
− | | |
− | <hr>
| |
− | | |
− | ==== IKO INDUSTRIES LTD. ====
| |
− | | |
− | <i>Manufacturer:</i> <b><i>IKO INDUSTRIES LTD.</i></b>
| |
− | | |
− | <i>Contact Address</i>: See Membership List, Section 1
| |
− | | |
− | <i>Product Group: </i><b><i>POLYISOCYANURATE ROOF INSULATION</i></b>
| |
− | | |
− | <i>Country of Origin :</i> Canada
| |
− | | |
− | <i>Country of Manufacture:</i> Canada
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | IKO Industries Ltd. is a Canadian manufacturer of polyisocyanurate insulations. The IKOTHERM III insulation panels are manufactured with non-asphaltic inorganic coated glass fiber facers for use in virtually all roof assemblies.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td colspan=2>RSI value = 1.05 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength</td>
| |
− | <td colspan=2>140 kpa [20 lb / sq. in.]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=2>All conventional single-ply, modified and built-up roofing systems</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=2>Conforms to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>FM-Class 1, I-60, I-90</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>CAN/ULC S-126, S-107</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m<br>(4' x 4')</td>
| |
− | <td>1.2 m x 2.4 m<br>(4' x 8')</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=2>Thicknesses of 25.4 mm to 104.1 mm (1" to 4.1")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td colspan=3>The following meet CAN/ULC -S704-01:</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Tensile Strength</td>
| |
− | <td colspan=2>35 kpa</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flexural Strength</td>
| |
− | <td colspan=2>(MD/XD) 607/479 kpa</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Dimensional Stability</td>
| |
− | <td colspan=2>2.0%</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Water Vapour Permeance</td>
| |
− | <td colspan=2>60ng / Pa*s*m<sup>2</sup></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Water Absorption</td>
| |
− | <td colspan=2>3.5%</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Service Temp.</td>
| |
− | <td colspan=2>Range: min: 40°C to max. 100°C</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <hr>
| |
− | | |
− | ==== ATLAS ROOFING CORPORATION ====
| |
− | | |
− | <i>Manufacturer:</i> <b>ATLAS ROOFING CORPORATION</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>POLYISOCYANURATE ROOF INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | All AC Foam product cores are state-of-the-art, closed-cell polyisocyanurate foam produced through the use of environmentally safe procedures. Polyisocyanurate, the most widely used and accepted foam insulation product in use today, provides superior fire performance characteristics and the ability to retain high R-Values. Designed for use in commercial roof applications. AC Foam products are available in a wide variety of facers, thicknesses and R-Values. Each AC Foam product is manufactured for exceptional strength, using dimensionally stable facers to add toughness to the boards and meet the high quality standards expected from Atlas.
| |
− | | |
− | <u>THE TWO ROOFING PRODUCTS PRESENTLY OFFERED ARE:</u>
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <tr>
| |
− | <td>AC Foam III</td><td>•Polyisocyanurate core integrally laminated to a specially coated facer (ideal for self-adhered membranes).</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>AC Foam Supreme</td><td>•Polyisocyanurate core integrally laminated to a tri-laminate foil facer.</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>ATLAS AC Foam</u>
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td>
| |
− | <td>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Foam Density</td>
| |
− | <td>32 kg / cu.m (2.0 lb / cu ft.)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength</td>
| |
− | <td>138 kpa (20 psi)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td>•AC Foam III: Do not use with hot applied membranes, i.e. coal tar or asphalt
| |
− | </td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards (AC Foam III)</td>
| |
− | <td>Conforms to CAN / ULC S704-01 / CAN / CGSB 51.26-M86</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>FM-Class 1, I-60, I-90</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>UL C S-126</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td>1.2 m x 1.2 m (48" x 48") for Asphalt or adhesive applied applications</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td>1.2 m x 2.4 m (48" x 96") for Mechanically fastened applications</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>TAPERED AC FOAM III</u>
| |
− | | |
− | Atlas Manufactures AC Foam III in a tapered profile to attain positive drainage while maintaining the highest thermal efficiency in a tapered system. All tapered panels are 4' x 4' in size with standard slopes of 1/8" / ft. with a 1/2" / ft. slopes for crickets. Computerized designs complete with shop drawings are available to the architect design authority.
| |
− | | |
− | <hr>
| |
− | | |
− | ==== CARLISLE SYNTEC CANADA ====
| |
− | | |
− | <i>Manufacturer: <b>CARLISLE SYNTEC CANADA</b></i>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group: <b>POLYISOCYANURATE ROOF INSULATION</b></i>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | Polyisocyanurate HP-H is a foam core insulation board covered on both sides with a medium weight fiber- glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Polyisocyanurate HP-H is recommended for use under Carlisle’s Sure-Seal, Brite-Ply and Sure-Weld Fully-Adhered and Mechanically-Fastened Roofing Systems and the Design “B” Ballasted Roofing System. Carlisle Polyisocyanurate HP-H insulation is UL and FM approved as a system component in certain Carlisle roofing assemblies. Please review the current Carlisle Design and / or Application Specifications for the appropriate use under a Carlisle Roofing System. Polyisocyanurate HP-H is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).
| |
− | | |
− | <u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u>
| |
− | | |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td>Nominal Thickness inches (mm)</td><td>• 1.0 (25)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR R-Value*</td><td>• 6.0</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR C-Value*</td><td>• 0.167</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>• 32,384 (3,009)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flute Span Ability, in. (mm)</td><td>• 2-5/8 (67)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Minimum Thickness, in (mm)</td><td>• 0.95 (24)</tD>
| |
− | </tr>
| |
− | </table>
| |
− | <u>PHYSICAL PROPERTIES:</u>
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Service Temperature, range if ºF (ºC)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | Carlisle Polyisocyanurate HP-H meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.
| |
− | | |
− | <hr>
| |
− | | |
− | | |
− | ==== SIPLAST CANADA INC. ====
| |
− | | |
− | <i>Manufacturer: <b>SIPLAST CANADA INC.</b></i>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group: <b>POLYISOCYANURATE ROOF INSULATION</b></i>
| |
− | | |
− | <i>Country of Origin:</i> USA/CANADA
| |
− | | |
− | <i>Country of Manufacture:</i> USA/CANADA
| |
− | | |
− | | |
− | <u>PRODUCT DESCRIPTION</u>
| |
− | | |
− | | |
− | The roofing assembly/material information published in the RGC Roofing Practices Manual does NOT represent a complete set of manufactureer's data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | Paratherm and Paratherm K are state of the art closed cell polyisocyanurate foam insulation products that provide superior R value insulation characteristics and fire resistance. Paratherm and Paratherm K offer two types of facers for use in commercial and industrial roof system applications. The facers used provide increased dimension stability as compared to organic facers. Paratherm and Paratherm K are available in a wide variety of thickness from 25mm (1") to over 100mm (4"). All products are produced to high exacting standards that meet CAN/ULC/CGSB and FM protocols.
| |
− | | |
− | | |
− | <u>Product Types</u>
| |
− | | |
− | Paratherm K - Non asphaltic inorganic facer
| |
− | | |
− | Paratherm - Specialty coated facer ideal for self adhered membrane application
| |
− | | |
− | | |
− | <u>Product Details</u>
| |
− | | |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td>Long Term Thermal Resistance (LTTR):</td><td> RSI Value=1.06/25mm (1") [R Value = 6.0/25mm (1")]</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength:</td><td> Paratherm - 138kpa (20 lb psi)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td> </td><td> Paratherm K - 140 kpa (20lb psi)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses:</td><td> Paratherm - Do no use with hot applied membranes</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td> </td><td> Paratherm K - 140 kpa (20 lb psi)</tD>
| |
− | </tr>
| |
− | <tr> <td>Standard Sizes:</td><td> 1.2m x 1.2m (48" x 48") for asphalt or adhesive applications</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td> </td><td> 1.2m x 2.4m (48" x 96") for mechanically attached systems</tD>
| |
− | | |
− | <td>Standards (Paratherm K):</td><td> Conforms to CAN/ULC-s704.01/CAN/CGSB 51.26-M86 FM Class 1, I-60, I-90, CAN/ULC S-126,S-107</tD>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <hr>
| |
− | | |
− | | |
− | ==== HUNTER PANELS LLC ====
| |
− | | |
− | <i>Manufacturer: <b>HUNTER PANELS LLC</b></i>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group: <b>POLYISOCYANURATE ROOF INSULATION</b></i>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | <u>H-Shield CG:</u>
| |
− | | |
− | Polyisocyanurate H-Shield CG is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate H-Shield CG insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield CG is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR). | |
− | | |
− | <u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u>
| |
− | | |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td>Nominal Thickness inches (mm)</td><td>• 1.0 (25)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR R-Value*</td><td>• 6.0</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR C-Value*</td><td>• 0.167</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>• 32,384 (3,009)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flute Span Ability, in. (mm)</td><td>• 2-5/8 (67)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Minimum Thickness, in (mm)</td><td>• 0.95 (24)</tD>
| |
− | </tr>
| |
− | </table>
| |
− | <u>PHYSICAL PROPERTIES:</u>
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Service Temperature, range if ºF (ºC)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | Hunter Panels Polyisocyanurate H-Shield CG meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.
| |
− | | |
− | <u>H-Shield Premier:</u>
| |
− | | |
− | Polyisocyanurate H-Shield Premier is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate H-Shield Premier insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield Premier is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).
| |
− | | |
− | <u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u>
| |
− | | |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td>Nominal Thickness inches (mm)</td><td>• 1.0 (25)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR R-Value*</td><td>• 6.0</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR C-Value*</td><td>• 0.167</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>• 32,384 (3,009)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flute Span Ability, in. (mm)</td><td>• 2-5/8 (67)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Minimum Thickness, in (mm)</td><td>• 0.95 (24)</tD>
| |
− | </tr>
| |
− | </table>
| |
− | <u>PHYSICAL PROPERTIES:</u>
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Service Temperature, range if ºF (ºC)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | Hunter Panels Polyisocyanurate H-Shield Premier meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.
| |
− | | |
− | <u>H-Shield Composite:</u>
| |
− | | |
− | Polyisocyanurate H-Shield Composite is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate H-Shield Composite insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield Composite is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).
| |
| | | |
− | <u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u> | + | ==BUR and Hot-mopped Applications only== |
| + | <div id=3.8Fibreboard> |
| | | |
− | <table border=0 cellpadding=5 cellspacing=0>
| + | ===Fibreboard Roof Insulation=== |
− | <tr>
| |
− | <td>Nominal Thickness inches (mm)</td><td>• 1.0 (25)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR R-Value*</td><td>• 6.0</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>LTTR C-Value*</td><td>• 0.167</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>• 32,384 (3,009)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flute Span Ability, in. (mm)</td><td>• 2-5/8 (67)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Minimum Thickness, in (mm)</td><td>• 0.95 (24)</tD>
| |
− | </tr>
| |
− | </table>
| |
− | <u>PHYSICAL PROPERTIES:</u>
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Service Temperature, range if ºF (ºC)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | Hunter Panels Polyisocyanurate H-Shield Composite meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.
| |
− | | |
− | | |
− | | |
− | <hr>
| |
− | | |
− | === Fibreboard Roof Insulation === | |
| Fibreboard insulation is composed of wood, cane, or other vegetable fibres and waterproofing binders. A water slurry containing the wood fibres and waterproofing binders is deposited onto a moving screen. The water drains through the screen and the remaining mass is heated in an oven or dryer to produce the finished product. Fibreboard roof insulation is produced in several forms: | | Fibreboard insulation is composed of wood, cane, or other vegetable fibres and waterproofing binders. A water slurry containing the wood fibres and waterproofing binders is deposited onto a moving screen. The water drains through the screen and the remaining mass is heated in an oven or dryer to produce the finished product. Fibreboard roof insulation is produced in several forms: |
| | | |
Line 1,729: |
Line 312: |
| * Coated with asphalt | | * Coated with asphalt |
| | | |
− | Fibreboard Roof Insulation that is adhered in a roof assembly with hot asphalt or asphaltic-based adhesives <u>must</u> have an asphalt coating on the top and bottom surfaces (minimum coated two sides) to meet RGC Guarantee Standards. Fibreboard for use as roofing insulation is manufactured to meet or exceed the requirements of CAN / ULC-S706 (Insulating Fibreboard), Type I (Roof Board). | + | Fibreboard Roof Insulation that is adhered in a roof assembly with hot asphalt or asphaltic-based adhesives <u>must</u> have an asphalt coating on the top and bottom surfaces (minimum coated two sides) to meet '''''RoofStar Guarantee Standards'''''. Fibreboard for use as roofing insulation is manufactured to meet or exceed the requirements of CAN / ULC-S706 (Insulating Fibreboard), Type I (Roof Board). |
| | | |
| Fibreboard roof insulation provides the following properties and advantages: | | Fibreboard roof insulation provides the following properties and advantages: |
Line 1,741: |
Line 324: |
| * Stable K-value (the thermal conductivity does not change with aging) | | * Stable K-value (the thermal conductivity does not change with aging) |
| * Retains roofing nails | | * Retains roofing nails |
| + | |
| | | |
| The possible disadvantages or precautions involved in the use of fibreboard insulation include: | | The possible disadvantages or precautions involved in the use of fibreboard insulation include: |
Line 1,748: |
Line 332: |
| * Organic in nature and will rot on exposure to moisture. | | * Organic in nature and will rot on exposure to moisture. |
| | | |
− | ==== Building Products of Canada Corp. ====
| + | </div><!-- mainBodyDiv --> |
− | * Petroleum Paraffin-impregnated fibreboard conforming to CAN / ULC - S706-09
| + | </div><!-- row --> |
− | | + | <div class="col-md-12"> |
− | ==== IKO INDUSTRIES INC. ====
| |
− | * Asphalt-impregnated coated fibreboard conforming to CAN / ULC - S706-09
| |
− | | |
− | ==== LOUISEVILLE SPECIALTY PRODUCTS INC. ====
| |
− | * Petroleum Paraffin - Natural Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Petroleum Paraffin - High Density natural Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Asphalt Coated (6 sides) Natural Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Asphalt and Wax Impregnated Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Asphalt and Wax Impregnated High Density Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Securpan - Fire Resistant Fibreboard conforming to CAN / ULC - S706-09
| |
− | * Securpan - Asphalt Coated (one side) Fire Resistant Fibreboard conforming to CAN / ULC - S706-09
| |
− | | |
− | === Perlitic ===
| |
− | Perlite ore is a volcanic glass with a natural water content characteristic. When this ore is heated to approximately +930<sup>o</sup>C (+1700<sup>o</sup>F) the water vaporizes and the ore expands into glass spheroids. The expanded perlite ore may be mixed into a water slurry formulation containing cellulose fibre, a small amount of asphalt, and sometimes starch. The slurry is then dried into boards and cut to size. The top surface is usually treated to minimize bitumen absorption.
| |
− | | |
− | Perlitic roof insulation provides the following properties and advantages:
| |
− | * Compatible with asphalt
| |
− | * Compatible with most roof system components
| |
− | * Resistant to thermal conductivity
| |
− | * Resistant to fire
| |
− | * Resistant to impact
| |
− | * Resistant to thermal cycling (dimensionally stable)
| |
− | * Unaffected by asphalt application temperatures
| |
− | * Stable K-value
| |
− | * Retains roofing nails
| |
− | | |
− | The possible disadvantages or precautions involved in the use of perlitic roof insulation include:
| |
− | * Absorbs moisture (protect from the effects of weathering)
| |
− | * Heavy equipment may compress boards causing possible debonding of the insulation from the deck
| |
− | * Extremely friable (crushable); proper compounding and correct grading is important
| |
− | * Relatively low thermal values.
| |
− | | |
− | | |
− | <hr>
| |
− | | |
− | <i>Manufacturer:</i> <b>JOHNS MANVILLE CORPORATION</b>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>PERLITIC ROOF INSULATION</b>
| |
− | | |
− | <i>Country of Origin:</i> USA
| |
− | | |
− | <i>Country of Manufacture:</i> USA
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | <u>FESCO BOARD</u>
| |
− | | |
− | Fesco Board is a homogeneous board composed of expanded perlite, a volcanic ore, blended with selected binders and fibers. The perlite particles are subjected to intense heat, which causes them to expand approximately fifteen times their original size. The resulting glass-like beads contain air cells, which provide high insulating efficiency.
| |
− | | |
− | The top surface of Fesco Board is sealed with Top-Loc coating to ensure positive adhesion of a built-up or modified bitumen membrane. The minimum recycled content is 25% by weight.
| |
− | | |
− | Fesco Board has excellent fire resistance and is approved for use in Factory Mutual approved constructions. When applied over rigid decks, Fesco Board’s high laminar tensile strength resists damage from on-the-job and maintenance traffic, offers an excellent substrate for all roofing membranes, and effectively bridges flute openings in metal decks. Because of its perlite composition and low water absorption rates, Fesco Board is dimensionally stable.
| |
− | | |
− | <table border=0 cellpadding=10 cellspacing=0>
| |
− | <tr>
| |
− | <td>Thermal Resistance</td>
| |
− | <td colspan=3>RSI = .49 / 25 mm (R value = 2.78 / inch)</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Uses</td>
| |
− | <td colspan=3>Fesco Board is a rigid, thermal roof insulation for use in built-up, modified bitumen and some single ply roofing systems. It may be applied using hot bitumen and / or mechanical fasteners. It may be used as a primary or overlayment board.</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standards</td>
| |
− | <td colspan=3>CSA Standard A284-1976</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=3>CAN / CGSB 51.10-92</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=3>Underwriters Laboratory Canada</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Standard Sizes</td>
| |
− | <td align=center>0.6 m x 1.2 m<br>(24" x 48")</td>
| |
− | <td align=center>1.2 m x 1.2 m<br>(48" x 48")</td>
| |
− | <td align=center>1.2 m x 2.4 m<br>(48" x 96")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td></td>
| |
− | <td colspan=3>Thicknesses - 18 mm (3/4"), 25 mm (1"), 38 mm (1.5"), 50 mm (2")</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Compressive Strength</td>
| |
− | <td colspan=3>CSA A284-1976 34 psi</td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td>Density:</td>
| |
− | <td colspan=3>CSA A284-1976 13 pcf</td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | <u>TAPERED FESCO BOARD</u>
| |
− | | |
− | Tapered Fesco is supplied in .61 m x 1.22 m (24" x 48") or 1.22 m x 1.22 m (48" x 48") boards, custom cut and tapered to 5.2 mm / m (1/16" / ft.), 10.4 mm / m (1/8" / ft.), 20.8 mm / m (1/4" / ft.), or 41.6 mm / m (1/2" / ft.) slope depending on the need. Custom sizes are available. Johns Manville’s Tapered Design Center has computerized design service, as well as shop drawings for application for the architect and roofing contractor.
| |
− | | |
| <hr> | | <hr> |
| | | |
− | === Mineral Fibre Roof Insulation ===
| + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
− | Mineral fibre roof insulations are composed of rock fibres with a thermoset resin and surfaced with glass fibre scrim on the top surface. These boards can provide a suitable surface for directly mopped bituminous membranes, however, a minimum one layer fibreboard overlay is recommended.
| + | </div> |
− | | |
− | Mineral fibre roof insulation may provide the following properties and advantages:
| |
− | * compatible with asphalt
| |
− | * compatible with most roof systems
| |
− | * resistant to thermal conductivity
| |
− | * excellent resistance to the effects of moisture
| |
− | * resistant to fire
| |
− | * resistant to cell deterioration (non-corrosive)
| |
− | * resistant to thermal cycling (dimensionally stable)
| |
− | * stable K value (thermal conductivity does not change with age)
| |
− | * conforms to substrate irregularities
| |
− | * can be hot mopped or mechanically fastened
| |
− | | |
− | The possible disadvantages or precautions involved in the use of mineral fibre roof insulation:
| |
− | * heavy equipment may compress the insulation and cause delamination of the membrane
| |
− | * not intended for use under high traffic deck surfaces
| |
− | | |
− | Mineral fibre roof insulation should meet or exceed CAN / ULC S126.M86.
| |
− | | |
− | <hr>
| |
− | | |
− | <i>Manufacturer: <b>SOPREMA INC.</b></i>
| |
− | | |
− | <i>Contact Address: </i>See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>SOPRAROCK STONE WOOL ROOF INSULATION</b></i>
| |
− | | |
− | <i>Country of Origin:</i> Denmark
| |
− | | |
− | <i>Countryof Manufacture: </i>Canada
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | SOPRAROCK STONE WOOL is a mono or dual density mineral wool fibre insulation made from basalt rock and slag. It is a non-combustible, has excellent fire resistant, and is an extremely dimensionally stable insulation with excellent acoustic properties. It is a water repellent yet vapour permeable insulation made from natural and recycled products, is impact resistant, and its thermal value and excellent physical properties make it an exceptional choice for use in the commercial roofing market in both new and re-roof applications as a primary insulation or an overlay insulation. Soprarock Stone wool contributes significant advantages to long term performance of roofing membrane assemblies.
| |
− | | |
− | <u>SOPRAROCK MD & SOPRAROCK MD PLUS</u>
| |
− | | |
− | Soprarock MD is mono-density mineral wool for use as a cover board for other insulations or over-top applications and can be mechanically fastened or hot mopped in a full bed of bitumen. Soprarock MD PLUS has an integral bitumen coating factory applied to allow for torch applied, hot applied or cold applied adhered membrane assemblies direct to the insulation.
| |
− | | |
− | Thickness - mm (inches) - 25 (1”)
| |
− | | |
− | Dimensions - m (ft.) - 1.2 x 1.2 (4’ x4’)
| |
− | | |
− | Long Term Thermal Resistance - Stable - ASTM C 518 (C 177) RSI Value - 0.62 (R-3.5) per 25mm (1”)
| |
− | | |
− | Compressive Strength - 25mm (1”) thickness - ASTM C165 - 84 kPa (12.1 psi)
| |
− | | |
− | Density (kg/m2) - ASTM C 612-00 - Actual - 176 (11 lb/ft3)
| |
− | | |
− | Dimensional Stability, linear shrinkage (% @ 177 C [350 F]) - ASTM C 356 - 0.01%
| |
− | | |
− | Water Absorption (%) - ASTM C 209 - < 1.0
| |
− | | |
− | <u>SOPRAROCK DD & DD PLUS</u>
| |
− | | |
− | Soprarock DD is dual-density mineral wool with a rigid upper surface for durability and enhanced strength. It is intended for use as a primary insulation in commercial, industrial, and institutional new and re-roof applications and can be mechanically fastened or hot mopped in a full bed of bitumen. Soprarock DD PLUS has an integral bitumen coating applied to allow for torch applied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
| |
− | | |
− | Thickness - mm (inches) - 25 (1”) to 150 (6”) in 12mm (1/2”) increments
| |
− | | |
− | Dimensions - m (ft) - .12 x 1.2 (4’ x 4’)
| |
− | | |
− | Long Term Thermal Resistance - Stable - ASTM C518 (C 177) - RSI Value - 0.65 (R 3.7) per 25mm (1”)
| |
− | | |
− | Compressive Strength - ASTM C 165
| |
− | * Top Layer at 10% - kPa (psi) 139 (20.2 psi)
| |
− | * Top Layer at 25% - kPa (psi) 252 (37.0 psi)
| |
− | * 75mm (3”) thickness - kPs (psi) 71 (10.3 psi)
| |
− | * 75mm (3”) thickness - kPa (psi) 103.5 (15psi)
| |
− | | |
− | Density (kg/m3) - Formed as a monolithic structure - ASTM C612-00 - Actual
| |
− | * Top Layer - 220 (13.75 lb/ft3)
| |
− | * Bottom - Layer - 160 (10.0 lb/ft3)
| |
− | | |
− | Dimensional Stability - Linear Shrinkage (% at 177C (350F) - ASTM C 356 - 0.01%
| |
− | | |
− | Water Absorption (%) - ASTM C 209 - < 1.0
| |
− | | |
− | Water Vapour Sorption - ASTM C 1104 - 0.03
| |
− | | |
− | Soprema Inc. may modify the composition of its products without prior notice. Consequently orders will be filled according to the latest specifications.
| |
− | | |
− | <hr>
| |
− | | |
− | <i>Manufacturer: <b>Roxul INC.</b> </i>
| |
− | <i>Contact Address: </i> See Membership List, Section 1
| |
− |
| |
− | <i>Product Group: <b>TOPROCK DD STONE WOOL ROOF INSULATION</b></i>
| |
− | | |
− | <i>Country of Origin:</i> Denmark
| |
− | | |
− | <i>Country of Manufacture:</i> Canada
| |
− |
| |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RGC<i> Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | TOPROCK DD STONE WOOL Insulation is a monolithic dual density stone wool fibre insulation made from basalt rock and slag. It is a non-combustible and fire resistant, is extremely dimensionally stable with excellent acoustic properties. It is water repellent yet vapour permeable and made from natural and recycled products, is impact resistant, and its thermal value and excellent physical properties make it an exceptional choice for use in the commercial roofing market in both new and re-roof applications as a primary insulation or an overlay insulation. Toprock Stone wool contributes significant advantages to long term performance of roofing membrane assemblies.
| |
− | | |
− | <u>TOPROCK DD & DD PLUS</u>
| |
− | | |
− | <b>Toprock DD</b> is dual-density mineral wool with a rigid upper surface for durability and enhanced strength. It is intended for use as a primary insulation in commercial, industrial, and institutional new and re-roof applications. It can be mechanically fastened or hot mopped in a full bed of bitumen. <b>Toprock DD PLUS</b> has an integral bitumen coating applied to allow for torch applied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
| |
− | | |
− | Thickness - mm (inches) - 25 (1”) to 150 (6”) in 12mm (1/2”) increments except no 3” (only 3.25 R 12)
| |
− | | |
− | Dimensions - m (ft) - 1.2 x 1.2 (4’ x 4’)
| |
− | | |
− | Long Term Thermal Resistance - Stable - ASTM C518 (C 177) - RSI Value - 0.65 (R 3.7) per 25mm (1”)
| |
− | | |
− | Compressive Strength - ASTM C 165
| |
− | * Top Layer at 10% - kPa (psi) 139 (20.2 psi)
| |
− | * Top Layer at 25% - kPa (psi) 252 (37.0 psi)
| |
− | * 75mm (3”) thickness - kPs (psi) 71 (10.3 psi)
| |
− | * 75mm (3”) thickness - kPa (psi) 103.5 (15psi)
| |
− | | |
− | Density (kg/m3) - Formed as a monolithic structure - ASTM C612-00 - Actual
| |
− | *Top Layer - 220 (13.75 lb/ft3)
| |
− | *Bottom - Layer - 160 (10.0 lb/ft3)
| |
− |
| |
− | Dimensional Stability - Linear Shrinkage (% at 177C (350F) - ASTM C 356 - 0.01%
| |
− | | |
− | WaterAbsorption (%) - ASTM C 209 - < 1.0 - Water Vapour Sorption - ASTM C 1104 - 0.03
| |
− | | |
− | Roxul Inc. may modify the composition of its products without prior notice. Consequently orders will be filled according to the latest specifications.
| |
− | | |
− | === Lightweight Insulating Concrete ===
| |
− | | |
− | <hr>
| |
− | | |
− | <i>Manufacturer: <b>SIPLAST CANADA INC.</b></i>
| |
− | | |
− | <i>Contact Address:</i> See Membership List, Section 1
| |
− | | |
− | <i>Product Group:</i> <b>LIGHTWEIGHT INSULATING CONCRETE</b>
| |
− | | |
− | <i>Country of Origin:</i> France, USA, Germany, Poland, Denmark
| |
− | | |
− | <i>Year First Installed: BC:</i> 2003
| |
− | | |
− | <i>Canada:</i> 1995
| |
− | | |
− | <i>Foreign:</i> 1935
| |
− | | |
− | <u>DESCRIPTION</u>
| |
− | | |
− | The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | NVS and Insulcel are composite systems that combine the unique properties of Lightweight insulating concrete (LWIC) and premium expanded polystyrene (EPS) foam insulation. The polystyrene insulation board can be installed in thicknesses necessary for high insulation values and in a stair stepped fashion, facilitating a positive slope to drain.
| |
− | | |
− | Poured 25 mm (1") for NVS and 50 mm (2") for Insulcel thickness over EPS insulation, these LWIC systems have been engineered for use over non-slotted or slotted galvanized corrugated metal decks (Insulcel), structural concrtete substrates and, where appropriate, over existing roofs in recover applications. These systems provide high performance solutions to industry concerns that include moisture resistance, high compressive strength, dimensional stability, fire and wind resistance, stable R-values and environmental safety. As a reusable resource LWIC also provides LEED values and is re-roofable.
| |
− | | |
− | <u>PRODUCTS</u>
| |
− | | |
− | NVS concrete is a 1:3.5 volume ratio of Portland cement to patented NVS Concrete Aggregate.
| |
− | | |
− | INSULCEL concrete is a mixture of Insulcel-PB pregenerated cellular foam and Portland cement / water slurry.
| |
− | <table border=0 cellpadding=5 cellspacing=0>
| |
− | <tr>
| |
− | <td valign=top>Dry Density:</td>
| |
− | <td>NVS - 560 kilograms per cubic meter (Kg/cu.m), (35 lbs. pcf)<br>Insulcel - 480 kilograms per cubic meter (Kg/cu.m), (30 lbs. pcf)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td valign=top>Min. Compressive Strenght:</td>
| |
− | <td>NVS - 2070 kilopascals (kPa), (300 psi)<br> Insulcel - 1380 kilopascals, (kPa), (200 psi)</tD>
| |
− | </tr>
| |
− | <tr>
| |
− | <td valign=top>Uses:</td>
| |
− | <td>
| |
− | * Recover and existing roof system (consultant validated).
| |
− | * Compensate for irregularities in existing substrates - slope to drain.
| |
− | * High compressive strength reduces potential damage from foot and other traffic.
| |
− | * Monolithic Mass effect improves long term membrane performance.
| |
− | * LEED value.
| |
− | * Save disposal costs and space in landfills.
| |
− | * Temperature Restrictions - do not install below 0ºC or 32ºF.
| |
− | * Do not apply during or in the event of rain.
| |
− | * Improved contractor installation performance.
| |
− | </td>
| |
− | </tr>
| |
− | <tr>
| |
− | <td valign=top>Standards:</td>
| |
− | <tD>
| |
− | Factory Mutual
| |
− | * NVS 1-90 and 1-150
| |
− | * Insulcel RT 1-90 and 1-195
| |
− | Metro-Dade Product Control No. 02-0411.01 and 03-320.13
| |
− | ASTM C332, ASTM C578
| |
− | </td>
| |
− | </tr>
| |
− | </table>
| |
− | | |
− | | |
− | | |