1 WORK INCLUDED
- (1) Underlayment And Eave Protection
- One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
- (2) Edge Metal Flashing
- Installed to manufacturer’s printed instructions.
Note: This specification is applicable to slopes 1:6 (2" in 12") and greater.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: * Refer to RGC Guarantee Standards for additional requirements.