1 WORK INCLUDED
(1) Underlayment: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).
(2) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Architectural Metal Roof Panel
(4) Flange: Set in two continuous beads of accepted caulking.
(5) Preformed Penetration Collar
(6) High Domed, Gasketed, Cladding Type Screws: Flange fastened to manufacturer’s specifications.
(7) Seal Between Pipe And Flashing: Continuous tooled bead of accepted caulking.
(8) Stainless Steel Drawband
(9) Water Tight Back Up Storm Collar: Installed where practical.
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Location Of Penetrations - must not interfere with standing seams or trapezoidal and intermediate ribs.
(C) Opening In Roof Deck - must be large enough to allow for thermal movement of metal roof panels.
(D) Pipe Or Support Stand
NOTE: * Refer to RGC Guarantee Standards for additional requirements.