Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"

(Created page with "<hr> File:9.6.1.jpg ;WORK INCLUDED (1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guaran...")
 
Line 2: Line 2:
 
[[File:9.6.1.jpg]]
 
[[File:9.6.1.jpg]]
  
;WORK INCLUDED
+
 
 +
==== WORK INCLUDED ====
  
 
(1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications.
 
(1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications.
Line 14: Line 15:
 
(7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").  
 
(7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").  
  
;<i>WORK BY OTHERS</i>
 
  
<i>(A)</i><b>Acceptable Deck</b>: Concrete slab depicted.  
+
==== WORK BY OTHERS ====
 +
 
 +
<i>(A)<b>Acceptable Deck</b>: Concrete slab depicted.  
  
 
<b><i>NOTE: </i>Refer to <i>RGC Guarantee Standards E</i> for additional requirements.</b>
 
<b><i>NOTE: </i>Refer to <i>RGC Guarantee Standards E</i> for additional requirements.</b>

Revision as of 17:13, 23 December 2015


9.6.1.jpg


1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed a per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.

(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.

(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.

(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.

(7) Concrete Paver: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").


2 WORK BY OTHERS

(A)Acceptable Deck: Concrete slab depicted.

NOTE: Refer to RGC Guarantee Standards E for additional requirements.



Back to Waterproofing

Back to Waterproofing Construction Details