Main Page
Site Nav
Technical Updates
Sections
A - RoofStar Guarantee
B - Essential Elements
C - Accepted Materials
D - Low Slope Roofs
E - Steep Slope Roofs
F - Waterproofing Plazas, Promenades and Terraces
G - Construction Details
H - Build Your Own Roof
I - General Information
Go
Personal
Log in
Page
Template
Discussion
View source
History
Tools
Page information
Permanent link
Printable version
Special pages
Related changes
What links here
Main page
Random page
Help
Difference between revisions of "Template:MARS (TPO)"
Jump to:
navigation
,
search
Difference between revisions of "Template:MARS (TPO)"
Latest revision as of 15:38, 6 July 2023
(
view source
)
James Klassen
(
talk
|
contribs
)
(No difference)
Latest revision as of 15:38, 6 July 2023
Tested Assembly Report Data
Primary Materials
Other System Materials & Deck
Manufacturer
Dynamic Uplift Resistance
Roof
Assembly
Summary
Test Report
Membrane
Plies
Insulation
Overlay
Insulation
Deck
Overlay
Deck
Type
kPa
Psf
Carlisle Syntec Systems Canada
-3.4
-70
View summary
Membrane
: mechanically fastened
Insulation overlay
: mechanically fastened
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered or loose-laid and sealed at laps
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
CAR MARS 3-A
View options
Sure-Weld 45 mil TPO
Sure-Weld 60 mil TPO
Sure-Weld 80 mil TPO
1
View options
SecurShield HD Plus
DensDeck® Prime with EONIC Roof Board
MDensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
SecurShield
MATERIAL NAME
H-Shield CG (Hunter)
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Carlisle Syntec Systems Canada
-3.4
-71
View summary
Membrane
: mechanically fastened
Insulation overlay
: mechanically fastened
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered or loose-laid and sealed at laps
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
CAR MARS 4-A
View options
Sure-Weld 45 mil TPO
Sure-Weld 60 mil TPO
Sure-Weld 80 mil TPO
1
View options
SecurShield HD Plus
DensDeck® Prime with EONIC Roof Board
MDensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
SecurShield
MATERIAL NAME
H-Shield CG (Hunter)
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Elevate
(formerly Firestone)
-3.2
-67
View summary
Membrane
: mechanically fastened
Insulation overlay
: mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
FIR MARS 3-A
View options
Ultraply 1.2 mm TPO
Ultraply 1.6 mm TPO
1
View options
ISOGard HD Cover Board
Securerock Gypsum Fibre Roof Board
View options
Resista
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Elevate
(formerly Firestone)
-3.8
-80
View summary
Membrane
: mechanically fastened
Insulation overlay
: mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
FIR MARS 4-A
View options
Ultraply 1.2 mm TPO
Ultraply 1.6 mm TPO
1
View options
(Optional)
ISOGard HD Cover Board
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Resista
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Elevate
(formerly Firestone)
-4.2
-87
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
FIR MARS 4-B
View options
Ultraply 1.2 mm TPO
Ultraply 1.6 mm TPO
1
View options
(Optional)
ISOGard HD Cover Board
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Resista
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Elevate
(formerly Firestone)
-3.8
-80
View summary
Membrane
: mechanically fastened
Insulation overlay
: mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
FIR MARS 5-A
View options
Ultraply 1.2 mm TPO
Ultraply 1.6 mm TPO
1
View options
ISOGard HD Cover Board
Securerock Gypsum Fibre Roof Board
View options
Resista
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Elevate
(formerly Firestone)
-3
-63
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
FIR MARS 6-A
View options
Ultraply 1.2 mm TPO
Ultraply 1.6 mm TPO
1
View options
(Optional)
ISOGard HD Cover Board
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Resista
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-7.2
-150
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: loose-laid or mechanically fastened
Roof deck
IKO-MARS 5-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
Securerock Gypsum Fibre Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-5
-105
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: loose-laid or mechanically fastened
Roof deck
IKO-MARS 6-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
Securerock Gypsum Fibre Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-3.6
-75
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: loose-laid or mechanically fastened
Roof deck
IKO-MARS 7-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-5.7
-120
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: (optional) loose-laid or mechanically fastened
Roof deck
IKO-MARS 8-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-4.2
-87.5
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: (optional) loose-laid or mechanically fastened
Roof deck
IKO-MARS 9-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-4.8
-100
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: loose-laid or mechanically fastened
Roof deck
IKO-MARS 10-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-1.91
-40
View summary
Membrane
: mechanically fastened
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: (optional) loose-laid, adhered, or mechanically fastened
Roof deck
IKO-MARS 11-A
View options
Innovi 1.1 mm TPO
1
View options
None listed
View options
IKOTherm III
View options
None listed
Steel
IKO Industries Ltd.
-2.9
-61
View summary
Membrane
: mechanically fastened (induction)
Insulation overlay
: (optional) loose-laid or mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: (optional) loose-laid, adhered, or mechanically fastened
Roof deck
IKO-MARS 12-A
View options
Innovi 1.5 mm TPO
1
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
None listed
Steel
IKO Industries Ltd.
-3.45
-72
View summary
Membrane
: mechanically fastened
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid with overlay, or mechanically fastened
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or adhered
Deck overlay (thermal barrier)
: (optional) loose-laid or mechanically fastened
Roof deck
IKO-MARS 13-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
Steel
IKO Industries Ltd.
-2.7
-56.6
View summary
Membrane
: mechanically fastened (induction)
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: loose-laid or self-adhered
Deck overlay (thermal barrier)
: (optional) loose-laid, adhered, or mechanically fastened
Roof deck
IKO-MARS 14-A
View options
Innovi 1.5 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
None listed
Steel
IKO Industries Ltd.
-2.28
-47.5
View summary
Membrane
: mechanically fastened (induction)
Insulation overlay
: (optional) mechanically fastened
Insulation (top layer)
: loose-laid or mechanically fastened with overlay
Insulation (bottom layer)
: loose-laid or mechanically fastened
Air/Vapour control layer
: loose-laid or adhered
Deck overlay (thermal barrier)
: (optional) loose-laid or mechanically fastened
Roof deck
IKO-MARS 15-A
View options
Innovi 1.1 mm TPO
Innovi 1.5 mm TPO
Innovi 1.9 mm TPO
1
View options
IKOTherm CoverShield
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
IKOTherm III
View options
Securerock Gypsum Fibre Roof Board
Steel
Johns Manville Corp.
-3.6
-75
View summary
Membrane
: mechanically fastened
Insulation overlay
: None listed
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhering
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
JM MARS 3-A
View options
JM TPO-45
JM TPO-60
JM TPO-80
1
View options
None listed
View options
ENRGY 3 CGF
Fesco Board
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel
Johns Manville Corp.
-5
-105
View summary
Membrane
: mechanically fastened
Insulation overlay
: None listed
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhering
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
JM MARS 4-A
View options
JM TPO-45
JM TPO-60
JM TPO-80
1
View options
None listed
View options
ENRGY 3 CGF
Fesco Board
View options
(Optional)
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Steel