Difference between revisions of "SBS Metal Edge Termination"

Jump to: navigation, search

Difference between revisions of "SBS Metal Edge Termination"

(Created page with "File:10.3.2.2.jpg === WORK INCLUDED === (1) <b>Vapor Retarder: </b>If required by design authority (2) <b>Insulation:</b> See list of accepted materials in Section 2.2...")
 
(WORK INCLUDED)
 
(53 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[File:10.3.2.2.jpg]]
+
{{Template:RPM Info}}
  
=== WORK INCLUDED ===
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
(1) <b>Vapor Retarder:  </b>If required by design authority
+
__NOTOC__
  
(2) <b>Insulation:</b> See list of accepted materials in Section 2.2.
+
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>SBS | Metal Edge Termination ([[SBS_Roof_Systems_Standard#10.3.4.2._Low_Profile_Edges | Article 10.3.4.2.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 +
<div class="panel panel-success">
 +
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:SBS 10.3.5.2 Metal Edge.jpg|class=img-responsive | link=https://rpm.rcabc.org/images/2/2b/SBS_10.3.5.2_Metal_Edge.jpg]]
 +
</div>
  
(3) <b>Insulation Overlay:</b>  Where required. See <i>RGC Guarantee Standard B4.1, B4.2 </i>and<i> C4.1</i>
+
</div><!-- COL-MD-6 -->
  
(4) <b>Primary Membrane and Membrane Protection:</b> Mechanically fasten to outside face of fascia (C).
+
<div class="col-md-6">
 +
=== WORK INCLUDED ===
 +
;(1) Primer: For self-adhered or torch-applied base membranes, as required by the membrane manufacturer.
 +
;(2) [[SBS Roof Systems Standard#PART_9|'''Base Membrane (field)''']]: Torch-applied, adhered, self-adhered (as illustrated), or mechanically attached (subject to deck type and wind uplift design requirements).  See Tables '''9.1''' and '''9.2''' for acceptable membrane types and securement options.  See '''9.3''' for application requirements.
 +
;(3) [[SBS Roof Systems Standard#PART_10|'''Mastic''']]: Applied beneath metal edge flashing.  Refer to [[SBS Roof Systems Standard#10.3.4.2. Low Profile Edges | Article 10.3.4.2.]]
 +
;(4) [[SBS Roof Systems Standard#PART_10|'''Metal Edge Flashing''']]: See '''13.3.2 Fabrication''' for manufacturing requirements.  See also [[SBS Roof Systems Standard#10.3.4.2. Low Profile Edges | Article 10.3.4.2., "Low Profile Edges]] for application standards and securement.  Hemmed edges are required; a kicked-out drip edge is optional but recommended (See [[SBS Roof Systems Standard#13.1.3.5. Fit and Finish | Article 13.1.3.5., "Fit and Finish"]].
 +
;(5) [[SBS Roof Systems Standard#PART_10|'''Base Membrane (flashing)''']]: Applied to overlap metal flashing and the field base membrane.
 +
;(6) [[SBS Roof Systems Standard#PART_9|'''Cap Membrane (field)''']]: Installed according to '''Part 9''' requirements and sealed along the exposed edge with an un-tooled bead of membrane compatible sealant ([[SBS Roof Systems Standard#10.3.4.2. Low Profile Edges | Article 10.3.4.2.]]).
  
(5) <b>Mastic:</b>  Trowel coating of compatible mastic.
+
<hr>
 
 
(6) <b>Metal Edge/Gravel-stop Flashing:</b> Minimum 100 mm (4") flange onto roof membrane, eave stop maximum 25 mm (1") high: embed in mastic and mechanically fasten alternately between centre and edge of flange at 100 mm (4") o/c; lap flashing 100 mm (4") minimum.
 
 
 
(7) <b>Membrane Flashing:</b>  Asphalt and gravel roofing systems, 2 overlapping plies of a minimum 2 mm reinforced SBS modified bitumen base sheet or minimum 180 g / m&#178; polyester felt. For flexible membrane systems, refer to manufacturer&#8217;s application details and RGC Guarantee Standards.
 
 
 
(8) <b>Asphalt:</b>  For asphalt and gravel built-up roofing systems only.
 
 
 
(9) <b>Gravel:</b>  For asphalt and gravel built-up roofing systems only.
 
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
(A) <b>Acceptable Deck</b>
+
;(A) Acceptable Substrate: Representative
 
+
;(B) Wall Assembly: Representative
(B) <b>Wood Blocking</b>
+
</div><!-- COL-6-MD -->
 
+
</div><!-- PANEL BODY -->
(C) <b>Wood Fascia</b>
+
</div><!-- PANEL -->
 
 
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 
  
 +
'''NOTE''': See the [[SBS Roof Systems Standard | '''Standard''']] for additional requirements.
  
 
<hr>
 
<hr>
  
 +
[[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''"SBS" Roof System Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
 
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
[[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''SBS Application'']]
 
 
 
[[SBS Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''SBS Construction Details'']]
 
 
 
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
 

Latest revision as of 17:55, 27 October 2023



Division D - Construction Details


SBS | Metal Edge Termination ( Article 10.3.4.2.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

SBS 10.3.5.2 Metal Edge.jpg

1 WORK INCLUDED

(1) Primer
For self-adhered or torch-applied base membranes, as required by the membrane manufacturer.
(2) Base Membrane (field)
Torch-applied, adhered, self-adhered (as illustrated), or mechanically attached (subject to deck type and wind uplift design requirements). See Tables 9.1 and 9.2 for acceptable membrane types and securement options. See 9.3 for application requirements.
(3) Mastic
Applied beneath metal edge flashing. Refer to Article 10.3.4.2.
(4) Metal Edge Flashing
See 13.3.2 Fabrication for manufacturing requirements. See also Article 10.3.4.2., "Low Profile Edges for application standards and securement. Hemmed edges are required; a kicked-out drip edge is optional but recommended (See Article 13.1.3.5., "Fit and Finish".
(5) Base Membrane (flashing)
Applied to overlap metal flashing and the field base membrane.
(6) Cap Membrane (field)
Installed according to Part 9 requirements and sealed along the exposed edge with an un-tooled bead of membrane compatible sealant ( Article 10.3.4.2.).

2 RELATED WORK BY OTHERS

(A) Acceptable Substrate
Representative
(B) Wall Assembly
Representative

NOTE: See the Standard for additional requirements.


Back to "SBS" Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.