Difference between revisions of "SBS/APP Material Page Template"
Difference between revisions of "SBS/APP Material Page Template"
Line 33: | Line 33: | ||
On March 8, 2024, the 2024 Edition of the "British Columbia Building Code" was published, removing reference to CGSB 37-GP-56M in Part 5 and requiring that all polymer-modified bituminous roofing membranes used in the Province of British Columbia conform to CSA standard A123.23 (See [https://www2.gov.bc.ca/assets/gov/farming-natural-resources-and-industry/construction-industry/building-codes-and-standards/revisions-and-mo/bcbc_2024.pdf#%5B%7B%22num%22%3A657%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2C0%2C392%2C0%5D Table 5.9.1.1.]. The CSA A123.23 Standard is also published in the National Building Code of Canada (2020), Part 5, [https://nrc-publications.canada.ca/eng/view/ft/?id=515340b5-f4e0-4798-be69-692e4ec423e8#%5B%7B%22num%22%3A1909%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2Cnull%2C533%2Cnull%5D Table 5.9.1.1.]. | On March 8, 2024, the 2024 Edition of the "British Columbia Building Code" was published, removing reference to CGSB 37-GP-56M in Part 5 and requiring that all polymer-modified bituminous roofing membranes used in the Province of British Columbia conform to CSA standard A123.23 (See [https://www2.gov.bc.ca/assets/gov/farming-natural-resources-and-industry/construction-industry/building-codes-and-standards/revisions-and-mo/bcbc_2024.pdf#%5B%7B%22num%22%3A657%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2C0%2C392%2C0%5D Table 5.9.1.1.]. The CSA A123.23 Standard is also published in the National Building Code of Canada (2020), Part 5, [https://nrc-publications.canada.ca/eng/view/ft/?id=515340b5-f4e0-4798-be69-692e4ec423e8#%5B%7B%22num%22%3A1909%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2Cnull%2C533%2Cnull%5D Table 5.9.1.1.]. | ||
− | Not all SBS and APP polymer-modified membranes accepted by the RGC prior to July 1, 2023 publish technical data sheets that align with the newer CSA Standard. While the RGC provides technical sheets for viewing in the Roofing Practices Manual, not | + | The testing requirements of CSA A123.23 are wide-ranging and replicated in the CSA tables (7.1 and 7.2) at the end of the RGC Acceptance Criteria document. If a membrane conforms to the CSA standard, all of the test criteria will be displayed on a product technical data sheet, and the published values for the product will match or exceed the minimum requirements published in those tables (where minimum criteria apply). Additionally, most of the product criteria in the CSA standard require testing the material in both "machine direction" (MD), meaning the direction of manufacturing, and "cross-machine direction" (MX), meaning across the direction of manufacturing. This must be done both before and after temperature conditioning. These rigorous requirements mean that the reader should be able to review the following membrane properties, in both Metric and Imperial units, for SBS-modified membranes (the requirements for APP-modified products are similar): |
+ | <ol> | ||
+ | <li>Thickness - 2 values | ||
+ | <li>Selvedge thickness - 2 values | ||
+ | <li>Mass per unit area - 2 values | ||
+ | <li>Back surface coating (only for heat-welded membranes) - 2 values | ||
+ | <li>Strain energy and peak load - 16 values | ||
+ | <li>Elongation at peak load, low temperature flexibility, low temperature flexibility after UV weathering, and compound stability - 8 values each | ||
+ | <li>Ultimate elongation and dimensional stability - 4 values each | ||
+ | <li>Resistance to puncture (where required) - "Pass" required | ||
+ | <li>Granule embedment (cap membranes only) - 2 values | ||
+ | </li> | ||
+ | </ol> | ||
+ | <br> | ||
+ | Not all SBS and APP polymer-modified membranes accepted by the RGC prior to July 1, 2023 publish technical data sheets that align with the newer CSA Standard. While the RGC provides technical sheets for viewing in the Roofing Practices Manual, some may not be current or conform to the standards they purport to align with. Therefore, the reader must validate this information independently of the RGC, to the reader's own satisfaction. For more about the product and the technical standards it meets, consult the local manufacturer's representative through the [https://www.rcabc.org/members/find-a-member/ "Find a Member"] page on the RCABC association website. | ||
− | Click the link below for the latest Technical Data Sheet supplied to the RGC by the manufacturer. | + | Click the link below for the latest Technical Data Sheet supplied to the RGC by the ''manufacturer''. |
<div style="width:100px; text-align: left;"> | <div style="width:100px; text-align: left;"> | ||
:[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/f/fa/Elevate_Una-Clad_UC-6_TDS.pdf|'''Technical Data Sheet''']] | :[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/f/fa/Elevate_Una-Clad_UC-6_TDS.pdf|'''Technical Data Sheet''']] |
Revision as of 20:54, 17 June 2024
Division C - Accepted Materials
Product Name
by Manufacturer name
Material Acceptance and Product Details
| |
|