| style="background-color:#FFE4C4"  | '''<big>Notice to Reader: Technical Data Sheets</big>'''
+
| style="background-color:#FFE4B5"  | '''<big>Notice and Disclaimer: Technical Data Sheets</big>'''
 
<br>
 
<br>
Bituminous roofing membranes modified with styrene butadiene styrene ("SBS") or attactic polypropylene ("APP") are governed by RGC Acceptance Criteria [https://rpm.rcabc.org/images/9/9e/Acceptance_Criteria_RGC_ACWP-MOD.pdf RGC ACWP-MOD] (applicable to membranes accepted after July 1, 2023).  However, all roofing membranes used in the Province of British Columbia must now conform to CSA standard A123.23, "Product specification for polymer-modified bitumen sheet, which is the standard published in both the British Columbia Building Code (2024), Part 5, [https://www2.gov.bc.ca/assets/gov/farming-natural-resources-and-industry/construction-industry/building-codes-and-standards/revisions-and-mo/bcbc_2024.pdf#%5B%7B%22num%22%3A657%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2C0%2C392%2C0%5D Table 5.9.1.1.] and in the National Building Code of Canada (2020), Part 5, [https://nrc-publications.canada.ca/eng/view/ft/?id=515340b5-f4e0-4798-be69-692e4ec423e8#%5B%7B%22num%22%3A1909%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2Cnull%2C533%2Cnull%5D Table 5.9.1.1.].  CSA Standard A123.23 forms the backbone of the RGC Acceptance Criteria and has replaced the older CGSB Standard CGSB 37-GP-56M, which was first published in 1980 and last revised in 1985 (withdrawn in 2013).
+
Bituminous roofing membranes modified with styrene butadiene styrene ("SBS") or attactic polypropylene ("APP") that are newly accepted by the RCABC Guarantee Corp. ("RGC") are governed by RGC Acceptance Criteria [https://rpm.rcabc.org/images/9/9e/Acceptance_Criteria_RGC_ACWP-MOD.pdf RGC ACWP-MOD] (applicable to membranes accepted after July 1, 2023).  The CSA Standard for these membranes, CSA A123.23 "Product specification for polymer modified
 +
bitumen sheet, prefabricated and reinforced", forms the backbone of the RGC Acceptance Criteria and has replaced the older CGSB Standard CGSB 37-GP-56M, which was first published in 1980 and last revised in 1985 (withdrawn in 2013).
  
Not all SBS and APP Polymer-modified membranes accepted by the RGC prior to July 1, 2023 publish technical data sheets that align with the newer CSA Standard. While the RGC provides technical sheets for viewing in the Roofing Practices Manual, not all may be current or even conforming to the standards they purport to align withTherefore, the reader must validate this information independently of the RGC, to the reader's own satisfaction.  For more about the product and the technical standards it meets, consult the local manufacturer's representative through the [https://www.rcabc.org/members/find-a-member/ "Find a Member"] page on the RCABC association website.
+
On March 8, 2024, the 2024 Edition of the "British Columbia Building Code" was published, removing reference to CGSB 37-GP-56M in Part 5 and requiring that all polymer-modified bituminous roofing membranes used in the Province of British Columbia conform to CSA standard A123.23 (See [https://www2.gov.bc.ca/assets/gov/farming-natural-resources-and-industry/construction-industry/building-codes-and-standards/revisions-and-mo/bcbc_2024.pdf#%5B%7B%22num%22%3A657%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2C0%2C392%2C0%5D Table 5.9.1.1.]The CSA A123.23 Standard is also published in the National Building Code of Canada (2020), Part 5, [https://nrc-publications.canada.ca/eng/view/ft/?id=515340b5-f4e0-4798-be69-692e4ec423e8#%5B%7B%22num%22%3A1909%2C%22gen%22%3A0%7D%2C%7B%22name%22%3A%22XYZ%22%7D%2Cnull%2C533%2Cnull%5D Table 5.9.1.1.].
  
Click the link below for the latest Technical Data Sheet supplied to the RGC by the manufacturer.
+
The testing requirements of CSA A123.23 are wide-ranging and replicated in the CSA tables (7.1 and 7.2) at the end of the RGC Acceptance Criteria document.  If a membrane conforms to the CSA standard, all of the test criteria will be displayed on a product technical data sheet, and the published values for the product will match or exceed the minimum requirements published in those tables (where minimum criteria apply).  Additionally, most of the product criteria in the CSA standard require testing the material in both "machine direction" (MD), meaning the direction of manufacturing, and "cross-machine direction" (MX), meaning across the direction of manufacturing.  This must be done both before and after temperature conditioning.  These rigorous requirements mean that the reader should be able to review the following membrane properties, in both Metric and Imperial units, for SBS-modified membranes (the requirements for APP-modified products are similar):
 +
<ol>
 +
<li>Thickness - 2 values
 +
<li>Selvedge thickness - 2 values
 +
<li>Mass per unit area - 2 values
 +
<li>Back surface coating (only for heat-welded membranes) - 2 values
 +
<li>Strain energy and peak load - 16 values
 +
<li>Elongation at peak load, low temperature flexibility, low temperature flexibility after UV weathering, and compound stability - 8 values each
 +
<li>Ultimate elongation and dimensional stability - 4 values each
 +
<li>Resistance to puncture (where required) - "Pass" required
 +
<li>Granule embedment (cap membranes only) - 2 values
 +
</li>
 +
</ol>
 +
<br>
 +
Not all SBS and APP polymer-modified membranes accepted by the RGC prior to July 1, 2023 publish technical data sheets that align with the newer CSA Standard.  While the RGC provides manufacturer-supplied technical sheets for viewing in the Roofing Practices Manual, the RGC does not validate them; while ''manufacturers'' (RCABC Associate Members) are required by policy to inform the RGC of changes to a product ([http://rpm.rcabc.org/images/d/df/Policy_A-041_Material_Acceptance_Criteria.pdf Policy A-041]), some data sheets may not be current and may not conform to the standards they purport to align with.  Therefore, the reader must verify this information independently of the RGC, to the reader's own satisfaction.  For more about the product and the technical standards it meets, consult the local manufacturer's representative through the [https://www.rcabc.org/members/find-a-member/ "Find a Member"] page on the RCABC association website.
 +
 
 +
Click the link below for the latest Technical Data Sheet supplied to the RGC by the ''manufacturer''.
 
<div style="width:100px; text-align: left;">
 
<div style="width:100px; text-align: left;">
 
:[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/f/fa/Elevate_Una-Clad_UC-6_TDS.pdf|'''Technical Data Sheet''']]
 
:[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/f/fa/Elevate_Una-Clad_UC-6_TDS.pdf|'''Technical Data Sheet''']]

Revision as of 21:06, 17 June 2024



Division C - Accepted Materials


Product Name
by Manufacturer name

Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Manufacturer
Name linked to website here
Accepted for the RoofStar Guarantee Program
Date here
Accepted for application in
Waterproofing Roof Systems
Grade-level Waterproofing Systems
Water-shedding Roof Systems
Acceptance Criteria
Product Summary
description here, using
breaks
(adapted from the Technical Data Sheet)
Conditions and Limitations
description here, using
breaks
Notice and Disclaimer: Technical Data Sheets


Bituminous roofing membranes modified with styrene butadiene styrene ("SBS") or attactic polypropylene ("APP") that are newly accepted by the RCABC Guarantee Corp. ("RGC") are governed by RGC Acceptance Criteria RGC ACWP-MOD (applicable to membranes accepted after July 1, 2023). The CSA Standard for these membranes, CSA A123.23 "Product specification for polymer modified bitumen sheet, prefabricated and reinforced", forms the backbone of the RGC Acceptance Criteria and has replaced the older CGSB Standard CGSB 37-GP-56M, which was first published in 1980 and last revised in 1985 (withdrawn in 2013).

On March 8, 2024, the 2024 Edition of the "British Columbia Building Code" was published, removing reference to CGSB 37-GP-56M in Part 5 and requiring that all polymer-modified bituminous roofing membranes used in the Province of British Columbia conform to CSA standard A123.23 (See Table 5.9.1.1.. The CSA A123.23 Standard is also published in the National Building Code of Canada (2020), Part 5, Table 5.9.1.1..

The testing requirements of CSA A123.23 are wide-ranging and replicated in the CSA tables (7.1 and 7.2) at the end of the RGC Acceptance Criteria document. If a membrane conforms to the CSA standard, all of the test criteria will be displayed on a product technical data sheet, and the published values for the product will match or exceed the minimum requirements published in those tables (where minimum criteria apply). Additionally, most of the product criteria in the CSA standard require testing the material in both "machine direction" (MD), meaning the direction of manufacturing, and "cross-machine direction" (MX), meaning across the direction of manufacturing. This must be done both before and after temperature conditioning. These rigorous requirements mean that the reader should be able to review the following membrane properties, in both Metric and Imperial units, for SBS-modified membranes (the requirements for APP-modified products are similar):

  1. Thickness - 2 values
  2. Selvedge thickness - 2 values
  3. Mass per unit area - 2 values
  4. Back surface coating (only for heat-welded membranes) - 2 values
  5. Strain energy and peak load - 16 values
  6. Elongation at peak load, low temperature flexibility, low temperature flexibility after UV weathering, and compound stability - 8 values each
  7. Ultimate elongation and dimensional stability - 4 values each
  8. Resistance to puncture (where required) - "Pass" required
  9. Granule embedment (cap membranes only) - 2 values


Not all SBS and APP polymer-modified membranes accepted by the RGC prior to July 1, 2023 publish technical data sheets that align with the newer CSA Standard. While the RGC provides manufacturer-supplied technical sheets for viewing in the Roofing Practices Manual, the RGC does not validate them; while manufacturers (RCABC Associate Members) are required by policy to inform the RGC of changes to a product (Policy A-041), some data sheets may not be current and may not conform to the standards they purport to align with. Therefore, the reader must verify this information independently of the RGC, to the reader's own satisfaction. For more about the product and the technical standards it meets, consult the local manufacturer's representative through the "Find a Member" page on the RCABC association website.

Click the link below for the latest Technical Data Sheet supplied to the RGC by the manufacturer.

Technical Data Sheet