Difference between revisions of "Manufacturers:Elevate"
Difference between revisions of "Manufacturers:Elevate"
(→Insulation) |
|||
(15 intermediate revisions by the same user not shown) | |||
Line 7: | Line 7: | ||
<big><big>Division C - Accepted Materials</big></big> | <big><big>Division C - Accepted Materials</big></big> | ||
<hr> | <hr> | ||
− | <big><big><big><big><big>Elevate</big></big></big></big></big><big> (formerly Firestone Building Products)</big><br> | + | <big><big><big><big><big>Elevate Commercial Roofing Systems</big></big></big></big></big><big> (formerly Firestone Building Products)</big><br> |
<big>Associate Member (Manufacturer)</big> | <big>Associate Member (Manufacturer)</big> | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 17: | Line 17: | ||
| | | | ||
;: | ;: | ||
− | ;Website: [https:// | + | ;Website: [https://holcimelevate.com/ca-en '''https://www.holcimbe.com/en'''] |
;Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org'''] | ;Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org'''] | ||
;Country of Origin: U.S.A. and Canada | ;Country of Origin: U.S.A. and Canada | ||
Line 25: | Line 25: | ||
:Canada: | :Canada: | ||
:Foreign: | :Foreign: | ||
+ | |- | ||
+ | | style="background-color:#FFE4B5" | '''<big>Notice and Disclaimer: Technical Data Sheets for SBS and APP Polymer-modified bituminous membranes</big>''' | ||
+ | <br> | ||
+ | Bituminous roofing membranes are governed by RGC Acceptance Criteria [https://rpm.rcabc.org/images/9/9e/Acceptance_Criteria_RGC_ACWP-MOD.pdf RGC ACWP-MOD] (applicable to membranes accepted after July 1, 2023). The CSA Standard for these membranes, CSA A123.23 "Product specification for polymer modified | ||
+ | bitumen sheet, prefabricated and reinforced", forms the backbone of the RGC Acceptance Criteria and has replaced the older CGSB Standard CGSB 37-GP-56M, which was withdrawn in 2015. | ||
+ | |||
+ | The "British Columbia Building Code" (2024) references the CSA A123.23 Standard in both Part 5 and Part 9 of Division B. The Standard is also published in the National Building Code of Canada (2020), and the City of Vancouver Building Bylaw (2024). | ||
+ | |||
+ | Not all manufacturers of SBS and APP polymer-modified membranes publish technical data sheets that fully align with the CSA Standard. Therefore, the reader must verify this information independently of the RGC, to the reader's own satisfaction. Consult the local manufacturer's representative through the [https://www.rcabc.org/members/find-a-member/ "Find a Member"] page on the RCABC association website. | ||
+ | |- | ||
|} | |} | ||
Line 33: | Line 43: | ||
====Insulation==== | ====Insulation==== | ||
:'''Polyisocyanurate Foam''' | :'''Polyisocyanurate Foam''' | ||
− | :[[Materials:ISOGARD CG| {{hilite | ISOGARD CG || 2024-June-15 }}]] | + | :[[Materials:Elevate ISOGARD CG| {{hilite | Elevate ISOGARD CG || 2024-June-15 }}]] |
====Insulation Overlay Panels==== | ====Insulation Overlay Panels==== | ||
:'''High-density Insulation Overlays''' | :'''High-density Insulation Overlays''' | ||
− | :[[Materials: | + | :[[Materials:ISOGARD HD Cover Board|Elevate ISOGard HD Cover Board]] |
====Felts (BUR)==== | ====Felts (BUR)==== | ||
Line 46: | Line 56: | ||
====SBS Polymer-Modified Bituminous Membranes==== | ====SBS Polymer-Modified Bituminous Membranes==== | ||
(See the membrane tables in [https://rpm.rcabc.org/index.php?title=Materials_by_Product_Category Division C]) | (See the membrane tables in [https://rpm.rcabc.org/index.php?title=Materials_by_Product_Category Division C]) | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</div> | </div> | ||
− | <div class="col-md- | + | <div class="col-md-4"> |
<big><big>'''Waterproofing Roofs'''</big></big> | <big><big>'''Waterproofing Roofs'''</big></big> | ||
<hr> | <hr> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
====EPDM Membranes==== | ====EPDM Membranes==== | ||
Line 77: | Line 65: | ||
:'''Reinforced''' | :'''Reinforced''' | ||
− | :[[Materials:RubberGard MAX| {{hilite | RubberGard MAX || 2023-June-16 }}]] | + | :[[Materials:Elevate RubberGard MAX (Reinforced) EPDM Membrane| {{hilite | Elevate RubberGard MAX (Reinforced) EPDM Membrane || 2023-June-16 }}]] |
− | :[[Materials:RubberGard MAX PT| {{hilite | RubberGard MAX PT || 2023-June-16 }}]] | + | :[[Materials:Elevate RubberGard MAX PT (Reinforced) EPDM Membrane| {{hilite | Elevate RubberGard MAX PT (Reinforced) EPDM Membrane|| 2023-June-16 }}]] |
:'''Unreinforced''' | :'''Unreinforced''' | ||
:[[Materials:RubberGard EcoWhite EPDM|RubberGard EcoWhite EPDM]] | :[[Materials:RubberGard EcoWhite EPDM|RubberGard EcoWhite EPDM]] | ||
− | :[[Materials:Rubbergard EPDM|Rubbergard EPDM]] | + | :[[Materials:Rubbergard EPDM|Rubbergard EPDM]] :<span style="color:#ff0000"> Under review by the RGC.</span> |
− | :[[Materials: | + | :[[Materials:Elevate RubberGard EPDM SA Membrane | Elevate RubberGard EPDM SA Membrane]] |
====TPO Membranes==== | ====TPO Membranes==== | ||
Line 93: | Line 81: | ||
====Liquid Membrane Flashing Systems==== | ====Liquid Membrane Flashing Systems==== | ||
+ | (See the membrane tables in [https://rpm.rcabc.org/index.php?title=Materials_by_Product_Category Division C]) | ||
+ | |||
'''Two-part Reinforced Liquid Membrane Flashing''' | '''Two-part Reinforced Liquid Membrane Flashing''' | ||
:[[Materials:Ultraflash|Ultraflash]] | :[[Materials:Ultraflash|Ultraflash]] | ||
Line 98: | Line 88: | ||
</div> | </div> | ||
− | <div class="col-md- | + | <div class="col-md-2"> |
<big><big>'''Waterproofing at Grade'''</big></big> | <big><big>'''Waterproofing at Grade'''</big></big> | ||
<hr> | <hr> | ||
====Liquid Membrane Flashing Systems==== | ====Liquid Membrane Flashing Systems==== | ||
+ | (See the membrane tables in [https://rpm.rcabc.org/index.php?title=Materials_by_Product_Category Division C]) | ||
:[[Materials:Ultraflash|Ultraflash]] | :[[Materials:Ultraflash|Ultraflash]] | ||
Line 115: | Line 106: | ||
====Metal Roofing==== | ====Metal Roofing==== | ||
− | :[[Materials: | + | :[[Materials:Elevate Una-Clad UC Metal Roof Panel Systems|Una-Clad UC Metal Roof Panel Systems]] |
</div> | </div> | ||
Latest revision as of 14:50, 25 June 2024
Division C - Accepted Materials
Elevate Commercial Roofing Systems (formerly Firestone Building Products)
Associate Member (Manufacturer)
Materials Listed by Category
|
|
Notice and Disclaimer: Technical Data Sheets for SBS and APP Polymer-modified bituminous membranes
The "British Columbia Building Code" (2024) references the CSA A123.23 Standard in both Part 5 and Part 9 of Division B. The Standard is also published in the National Building Code of Canada (2020), and the City of Vancouver Building Bylaw (2024). Not all manufacturers of SBS and APP polymer-modified membranes publish technical data sheets that fully align with the CSA Standard. Therefore, the reader must verify this information independently of the RGC, to the reader's own satisfaction. Consult the local manufacturer's representative through the "Find a Member" page on the RCABC association website. |
Waterproofing Roofs
Insulation
- Polyisocyanurate Foam
- Elevate ISOGARD CG
Insulation Overlay Panels
- High-density Insulation Overlays
- Elevate ISOGard HD Cover Board
Felts (BUR)
- Glass-fibre Felts
- Ply IV (BUR)
- Ply VI (BUR)
SBS Polymer-Modified Bituminous Membranes
(See the membrane tables in Division C)
Waterproofing Roofs
EPDM Membranes
(See the membrane tables in Division C)
- Reinforced
- Elevate RubberGard MAX (Reinforced) EPDM Membrane
- Elevate RubberGard MAX PT (Reinforced) EPDM Membrane
- Unreinforced
- RubberGard EcoWhite EPDM
- Rubbergard EPDM : Under review by the RGC.
- Elevate RubberGard EPDM SA Membrane
TPO Membranes
(See the membrane tables in Division C)
Liquid Membrane Flashing Systems
(See the membrane tables in Division C)
Two-part Reinforced Liquid Membrane Flashing
Water-shedding Roofs
Eave Protection & Underlayment (ASM)
- Self-adhered Materials
- CLAD-GARD SA Metal Underlayment
- CLAD-GARD MA Metal Underlayment
Metal Roofing
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.