Difference between revisions of "SBS Roof System Details"
Difference between revisions of "SBS Roof System Details"
Line 9: | Line 9: | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
− | :[[File:SBS Systems page thumb.JPG | link=http://rpm.rcabc.org/images/6/62/SBS_Systems_page_thumb.JPG | | + | :[[File:SBS Systems page thumb.JPG | link=http://rpm.rcabc.org/images/6/62/SBS_Systems_page_thumb.JPG |225 px]] |
− | + | :<small><small>Photo Credit: RCABC Image Library</small></small> | |
</div> | </div> | ||
Latest revision as of 15:35, 14 August 2024
- Division D - Construction Details
- Construction Details for SBS-modified Bitumen Membrane Roof Systems
- The drawings linked on this page are intended to represent a variety of SBS-modified Bitumen Membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturers’ specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
- For further information about SBS-modified Bitumen Membrane System designs and requirements, see the Standard for SBS-modified Bitumen Membrane Roof Systems.
Part 1 - General
Permitted Roof Systems ( Article 1.1.3.1.)
- Conventionally Insulated System (Typical)
- Conventionally Insulated System (Alternate)
- Protected Roof Assembly (Typical)
Part 6 - Air and Vapour Controls
Continuity and Support ( Article 6.3.2.1.)
Part 10 - Perimeters and Walls
General Application ( Article 10.3.2.3.)
- Membrane Termination A
- Membrane Termination B
- Membrane Termination C
- Membrane Termination D
- Membrane Termination E
- Membrane Termination F
Parapets ( Article 10.3.4.1.)
Low-profile Edges ( Article 10.3.4.2.)
Part 10 (continued)
Fire Separations ( Article 10.3.4.4.)
Doors, Windows, and Wall Openings ( Article 10.3.4.5.)
Expansion Joints ( Article 10.3.6.1.)
Control Joints (Roof Dividers) ( Article 10.3.6.2.)
Part 11 - Drainage
Cast-iron Roof Drains ( Article 11.3.3.2.)
Flanged Insert-type Roof Drains ( Article 11.3.3.6.)
Scuppers and Overflows ( Article 11.3.3.7.)
Part 12 - Penetrations and Curbs
Flashing Penetrations ( Article 12.3.2.1.)
- Plumbing Vent (Conventional Roof System)
- 2-Part Retrofit Flashing (Cable Penetration)
- Fall Protection Anchor in Roof
- Fall Protection Anchor in Wall
- SBS Fall Protection Anchor in Wall (Protected Roof System)
Curbs, Sleepers, and Equipment Pads ( Article 12.3.2.4.)
Railings, Ladders, and Other Attached Structures ( Article 12.3.2.7.)
Sealant Pockets ( Article 12.3.2.8.)
Part 13 - Linear Metal Flashing
- See the separate page, Construction Details for Linear Metal Flashings.
Part 14 - The Roof as a Platform
Structures and Equipment ( Article 14.3.2.7.)
Standard for SBS-modified Bitumen Membrane Roof Systems
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.