Difference between revisions of "Materials:SOPRANATURE Intensive-Conventional Vegetated Roof"
Difference between revisions of "Materials:SOPRANATURE Intensive-Conventional Vegetated Roof"
(4 intermediate revisions by the same user not shown) | |||
Line 24: | Line 24: | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
;System Summary: SOPRANATURE<sup>®</sup> ® Intensive Vegetated Systems by SOPREMA<sup>®</sup> correspond to heavy green roofs with more than 300 mm of SOPRAFLOR substrate. Vegetation types can include a wide variety of perennials, shrubs and trees that require frequent maintenance and heavy structural capacity. | ;System Summary: SOPRANATURE<sup>®</sup> ® Intensive Vegetated Systems by SOPREMA<sup>®</sup> correspond to heavy green roofs with more than 300 mm of SOPRAFLOR substrate. Vegetation types can include a wide variety of perennials, shrubs and trees that require frequent maintenance and heavy structural capacity. | ||
+ | ;Manufacturer Online Resource: [https://www.soprema.ca/en/catalogsearch/result/?q=intensive SORPANATURE Intensive Vegetated Roof Systems] | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | [[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | ||
Line 30: | Line 31: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;System Depth: 314.4 mm (12-3/8") | + | ;System Depth: 314.4 mm (12-3/8") to 314.4 mm (12-3/8") + |
− | ;Growing Media Depth: 304.8 mm (12") | + | ;Growing Media Depth: 304.8 mm (12") to 304.8 mm (12") + |
;Vegetation Profile: Wild flower meadows, grasses, perennials, annuals, small shrubs and vegetation with medium to high water needs (as specified by the ''Design Authority''/''Green Roof Design Professional''. See '''Conditions and Limitations''' below) | ;Vegetation Profile: Wild flower meadows, grasses, perennials, annuals, small shrubs and vegetation with medium to high water needs (as specified by the ''Design Authority''/''Green Roof Design Professional''. See '''Conditions and Limitations''' below) | ||
;Suitable climate zones: All BC zones, subject to manufacturer's approval | ;Suitable climate zones: All BC zones, subject to manufacturer's approval | ||
;System Components: | ;System Components: | ||
:'''Sedum Mats''' by Soprema, or non-sedum mat supplied by others* (Click [https://rpm.rcabc.org/images/5/5f/Soprema_Sopranature_Sedum_Mat_TDS.pdf here] for the Technical Data Sheet PDF) | :'''Sedum Mats''' by Soprema, or non-sedum mat supplied by others* (Click [https://rpm.rcabc.org/images/5/5f/Soprema_Sopranature_Sedum_Mat_TDS.pdf here] for the Technical Data Sheet PDF) | ||
− | :'''Sopraflor I''' growing media (Click [ | + | :'''Sopraflor I''' growing media (Click [https://rpm.rcabc.org/images/f/ff/Soprema_Sopranature_Sopraflor_X_%26_I_TDS.pdf here] for the Technical Data Sheet PDF) |
− | :'''Sopraretentio Mat''' (Click [ | + | :'''Sopraretentio Mat''' (Click [https://rpm.rcabc.org/images/7/7b/Soprema_Sopranature_Sopraretentio_Mat_TDS.pdf here] for the Technical Data Sheet PDF) |
− | :'''Soprafiltre''' (Click [ | + | :'''Soprafiltre''' (Click [https://rpm.rcabc.org/images/d/d1/Soprema_Sopranature_Soprafiltre_TDS.pdf here] for the Technical Data Sheet PDF) |
− | :'''Sopradrain Eco-5''' (Click [ | + | :'''Sopradrain Eco-5''' (Click [https://rpm.rcabc.org/images/7/7e/Soprema_Sopranature_Sopradrain_ECO-5_TDS.pdf here] for the Technical Data Sheet PDF) |
− | :'''Soprabarrier 30''' (Click [ | + | :'''Soprabarrier 30''' (Click [https://rpm.rcabc.org/images/b/bb/Soprema_Sopranature_Soprabarrier_20_%26_30_TDS.pdf here] for the Technical Data Sheet PDF) |
:Soprema approved tape | :Soprema approved tape | ||
− | :Sopranature<sup>®</sup> metal edging | + | :Sopranature<sup>®</sup> metal edging (Click [https://rpm.rcabc.org/images/f/f3/Soprema_Sopranature_Metal_Edging_TDS.pdf here] for the Technical Data Sheet PDF) |
− | :Sopranature<sup>®</sup> inspection chambers | + | :Sopranature<sup>®</sup> inspection chambers (Click [https://rpm.rcabc.org/images/e/e4/Soprema_Sopranature_Inspection_Chamber_TDS.pdf here] for the Technical Data Sheet PDF) |
+ | |||
+ | ::<sup>*</sup>See Conditions and Limitations | ||
;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
Line 50: | Line 53: | ||
</div> | </div> | ||
</div> | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 17:50, 31 October 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
SOPRANATURE® Intensive-Conventional Vegetated Roof
by Soprema Inc.
Material Acceptance and Product Details
|
|