− | ;'''Vegetated Roof System Manufacturer''': | + | ;'''Vegetated Roof System Manufacturer''': [https://www.nlsm.ca/ '''https://www.nlsm.ca/'''] |
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | <div style="text-align: left;"> | + | ;System Summary: The LiteN’Less™ II system is Next Level Stormwater Management's lightest vegetated system available. Lightweight and soilless, with no “loose” growing medium, its light weight avoids excessive loading and is therefore offered as a solution for roof retrofits. |
− | [[File:Extensive VR System (sedum tile).jpg| | + | <div style="text-align:left;"> |
+ | [[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | ||
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;System | + | ;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/extensive-systems/litenless-2/ LiteN’Less™ II System] |
− | ;System Depth: | + | ;System Depth: 30.7 mm (1-1/8") |
− | ;Growing Media Depth: | + | ;Growing Media Depth: 20 mm (13/16") |
− | ;Vegetation Profile: | + | ;Vegetation Profile: Moss-Sedum |
− | ;Suitable climate zones: | + | ;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval |
;System Components: | ;System Components: | ||
− | : | + | :'''NL718 Sedum Blanket''' (Click [https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf here] for the Technical Data Sheet PDF) |
− | : | + | :'''NL512 Retention Fleece''' (Click [https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf here] for the Technical Data Sheet PDF) |
− | : | + | ::'''NL512 Retention Fleece''' (Note that this system requires two (2) layers of fleece) |
− | : | + | :'''NL120 Root Barrier''' (Click [https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf here] for the Technical Data Sheet PDF) |
− | : | + | :'''NL200 Edging & Accessories''' (Click [https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf here] for the Technical Data Sheet PDF) |
+ | :'''NL210 Drain Box & Accessories''' | ||
+ | :'''NL220 Penetration Box''' | ||
+ | :'''NL WindProtect Plate''' | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
− | + | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | |
</div> | </div> | ||