+ | ;System Summary: Next Level Stormwater Management's original lightweight system, an older incarnation of the new updated soilless systems LiteN’Less II and LiteN’Less III. | ||
<div style="text-align:left;"> | <div style="text-align:left;"> | ||
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | [[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | ||
Line 29: | Line 30: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | |||
;System Depth: 40.7 mm (1-5/8") to 64.0 mm (2-1/2") | ;System Depth: 40.7 mm (1-5/8") to 64.0 mm (2-1/2") | ||
;Growing Media Depth: 25.4 mm (1") to 25.4 mm (1") | ;Growing Media Depth: 25.4 mm (1") to 25.4 mm (1") | ||
− | ;Vegetation Profile: | + | ;Vegetation Profile: Moss-Sedums |
− | ;Suitable climate zones: | + | ;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval |
;System Components: | ;System Components: | ||
− | : | + | :'''NL720 Sedum Blanket''' (Click [https://rpm.rcabc.org/images/f/f2/NLSM_NL720_Sedum_Blanket_2024_TDS.pdf here] for the Technical Data Sheet PDF) |
− | : | + | :'''NL512 Retention Fleece''' (Click [https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf here] for the Technical Data Sheet PDF) |
− | : | + | :'''NL512 Retention Fleece''' (Note that this system requires two (2) layers of fleece) |
− | : | + | :'''NL300 Drainage Mat''' (Conventional Roof) (Click [https://rpm.rcabc.org/images/4/40/NLSM_NL300_Drainage_Mat_TDS.pdf here] for the Technical Data Sheet PDF) or Stone Ballast (PMRA) |
− | : | + | :'''NL120 Root Barrier''' (Click [https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf here] for the Technical Data Sheet PDF) |
+ | :'''NL200 Edging & Accessories''' (Click [https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf here] for the Technical Data Sheet PDF) | ||
+ | :'''NL210 Drain Box & Accessories''' | ||
+ | :'''NL220 Penetration Box''' | ||
− | ;Conditions and Limitations: | + | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. |
+ | |||
+ | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||