Difference between revisions of "Materials:Carlisle Semi-Intensive Roof Garden System"
Difference between revisions of "Materials:Carlisle Semi-Intensive Roof Garden System"
Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | ;System Summary: '''Carlisle Semi-Intensive Roof Garden System''', also known as a "medium" green roof, is a built-in-place system with a ''growing media'' depth ranging from 12.7 cm (5 in) to 20.3 cm (8 in). ''Semi-Intensive systems'' are typically chosen for projects requiring greater water retention and/or a more diverse plant palette. Due to the | + | ;System Summary: '''Carlisle Semi-Intensive Roof Garden System''', also known as a "medium" green roof, is a built-in-place system with a ''growing media'' depth ranging from 12.7 cm (5 in) to 20.3 cm (8 in). ''Semi-Intensive systems'' are typically chosen for projects requiring greater water retention and/or a more diverse plant palette. Due to the increased media depth and variety of ''vegetation'' options, these systems require a heat-welded root barrier to protect the roof membrane. These systems also tend to be heavier and demand more maintenance and watering compared to ''extensive green roofs'' (Adapted from the manufacturer's summary). |
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | [[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | ||
Line 30: | Line 31: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | |||
;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] | ;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] | ||
+ | ;System Type: Semi-Intensive | ||
;System Depth: 158.8 mm (6-1/4") to 235 mm (9-1/4") | ;System Depth: 158.8 mm (6-1/4") to 235 mm (9-1/4") | ||
;Growing Media Depth: 127 mm (5") to 203.2 mm (8") | ;Growing Media Depth: 127 mm (5") to 203.2 mm (8") | ||
;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) | ;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) | ||
;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') | ;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') | ||
− | ;System Components: | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | : | + | :{| class="wikitable" |
− | + | |- | |
− | + | | | |
− | + | *[https://rpm.rcabc.org/images/d/db/Carlisle_Roof_Garden_Growth_Media_TDS.pdf '''Semi-Intensive Growth Media'''] | |
− | :''' | + | *[https://rpm.rcabc.org/images/9/96/Carlisle_Roof_Garden_MiraDRAIN_G4_TDS.pdf '''MiraDRAIN G4'''] |
− | + | *[https://rpm.rcabc.org/images/1/12/Carlisle_Roof_Garden_Aluminum_Edge_TDS.pdf '''Roof Garden Aluminum Edge'''] | |
+ | *[https://rpm.rcabc.org/images/e/ee/Carlisle_Roof_Garden_Aluminum_Drain_Box_TDS.pdf '''Roof Garden Aluminum Drain Box'''] | ||
+ | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
+ | *[https://rpm.rcabc.org/images/1/16/Carlisle_Roof_Garden_Root_Barrier_TDS.pdf '''Root Barrier'''] | ||
+ | *[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric'''] | ||
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | |} | ||
;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. |
Revision as of 22:27, 27 November 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
Carlisle Semi-Intensive Roof Garden System
by Carlisle SynTec Systems Canada
System/Material Acceptance and Product Details
| |
|