Difference between revisions of "Materials:Hydrotech Semi-intensive Garden Roof Assembly"
Difference between revisions of "Materials:Hydrotech Semi-intensive Garden Roof Assembly"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...") |
|||
(10 intermediate revisions by the same user not shown) | |||
Line 7: | Line 7: | ||
<big>Group - Vegetated Roof Systems</big> | <big>Group - Vegetated Roof Systems</big> | ||
<hr> | <hr> | ||
− | <big><big><big><big><big>Hydrotech Semi-intensive Garden Roof Assembly</big></big></big></big></big><br> | + | <big><big><big><big><big>Hydrotech Semi-intensive Garden Roof<sup>®</sup> Assembly</big></big></big></big></big><br> |
<big><big><big>by Hydrotech Membrane Corporation</big></big></big><br> | <big><big><big>by Hydrotech Membrane Corporation</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 17: | Line 17: | ||
| | | | ||
<div class="col-md-12"> | <div class="col-md-12"> | ||
− | <div class="col-md- | + | <div class="col-md-6"> |
;: | ;: | ||
− | ;'''Vegetated Roof System Manufacturer''': | + | ;'''Vegetated Roof System Manufacturer''': [http://en.hydrotechmembrane.ca/ '''Hydrotech Membrane Corporation'''] |
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
+ | ;System Summary: The Semi-Intensive Garden Roof<sup>®</sup> Assembly is considered a lightweight assembly, but with a slightly deeper soil depth, and is designed to support sod lawns as well as perennials. Lawns have unique needs due to the foot traffic they experience. Designers have the ability to create large lawn areas on rooftops using a Garden Roof Semi-Intensive<sup>®</sup> Assembly (See the link at right to the manufacturer's online resources page for more information).. | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;System | + | ;Manufacturer online resources: [https://en.hydrotechmembrane.ca/assemblies/garden-roof-assembly/semi-intensive Semi-intensive Garden Roof Assembly] |
− | ;System Depth: | + | ;System Type: Semi-Intensive |
− | ;Growing Media Depth: | + | ;System Depth: 203.2 mm (8") to 355.6 mm (14") |
− | ;Vegetation Profile: | + | ;Growing Media Depth: 152.4 mm (6") to 304.8 mm (12") |
− | ;Suitable climate zones: | + | ;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) |
− | ;System Components: | + | ;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') |
− | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) | |
− | : | + | :{| class="wikitable" |
− | : | + | |- |
− | : | + | | |
− | : | + | *[https://rpm.rcabc.org/images/c/c1/Hydrotech_LiteTop_Growing_Media_TDS.pdf '''Semi-Intensive Litetop<sup>®</sup> Growing Media'''] |
+ | *[https://rpm.rcabc.org/images/c/cb/Hydrotech_LiteTop_Aggregate_TDS.pdf '''Litetop<sup>®</sup> Aggregate'''] only for Gardendrain GR30 | ||
+ | *[https://rpm.rcabc.org/images/d/d6/Hydrotech_Gardendrain_GR25_TDS.pdf '''Gardendrain GR25'''] or [https://rpm.rcabc.org/images/e/e9/Hydrotech_Gardendrain_GR30_TDS.pdf '''Gardendrain GR30'''] | ||
+ | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
+ | *[https://rpm.rcabc.org/images/2/2a/Hydrotech_Root_Stop_TDS.pdf '''Root Stop Standard'''] or [https://rpm.rcabc.org/images/0/04/Hydrotech_Root_Stop_HD_TDS.pdf '''Root Stop HD'''] | ||
+ | *[https://rpm.rcabc.org/images/1/16/Hydrotech_Root_Stop_Tape_TDS.pdf '''Root Stop Tape'''] | ||
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | *[https://rpm.rcabc.org/images/0/0e/Hydrotech_GardenEdge_TDS.pdf '''GardenEdge<sup>®</sup>'''] | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
− | |||
</div> | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
+ | |||
+ | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 21:30, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
Hydrotech Semi-intensive Garden Roof® Assembly
by Hydrotech Membrane Corporation
Material Acceptance and Product Details
| |
|