Difference between revisions of "Materials:Hydrotech Extensive Garden Roof Assembly"
Difference between revisions of "Materials:Hydrotech Extensive Garden Roof Assembly"
(6 intermediate revisions by the same user not shown) | |||
Line 17: | Line 17: | ||
| | | | ||
<div class="col-md-12"> | <div class="col-md-12"> | ||
− | <div class="col-md- | + | <div class="col-md-6"> |
;: | ;: | ||
;'''Vegetated Roof System Manufacturer''': [http://en.hydrotechmembrane.ca/ '''Hydrotech Membrane Corporation'''] | ;'''Vegetated Roof System Manufacturer''': [http://en.hydrotechmembrane.ca/ '''Hydrotech Membrane Corporation'''] | ||
Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | + | ;System Summary: The Extensive Garden Roof<sup>®</sup> Assembly is designed for locations that will receive little maintenance or where structural capabilities are a concern. It is not intended for recreational use and is typically chosen for its appearance or to help reduce the "urban heat island" effect and minimize stormwater run-off. ''Extensive vegetated roofs'' only require a shallow growing media depth, generally as little as :75 mm to 150 (depending on the region), and therefore add little weight to the roof structure below when compared to a standard ballasted PMR roof (See the link at right to the manufacturer's online resources page for more information).. | |
− | ;System Summary: The Extensive Garden Roof<sup>®</sup> Assembly is designed for locations that will receive little maintenance or where structural capabilities are a concern. | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
− | <div class="col-md- | + | <div class="col-md-6"> |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
;: | ;: | ||
+ | ;Manufacturer online resources: [https://en.hydrotechmembrane.ca/assemblies/garden-roof-assembly/extensive Extensive Garden Roof Assembly] | ||
+ | ;System Type: Extensive | ||
;System Depth: 101.6 mm (4") to 203.2 mm (7") | ;System Depth: 101.6 mm (4") to 203.2 mm (7") | ||
;Growing Media Depth: 76.2 mm (3") to 152.4 mm (6") | ;Growing Media Depth: 76.2 mm (3") to 152.4 mm (6") | ||
;Vegetation Profile: varieties of sedums | ;Vegetation Profile: varieties of sedums | ||
− | ;Suitable climate zones: | + | ;Suitable climate zones: All BC zones, subject to manufacturer's approval |
− | ;System Components | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | + | :{| class="wikitable" | |
− | + | |- | |
− | + | | | |
− | * | + | *[https://rpm.rcabc.org/images/1/19/Hydrotech_Instagreen_Carpet_TDS.pdf '''Instagreen<sup>®</sup> Carpet'''] |
− | * | + | *[https://rpm.rcabc.org/images/c/c1/Hydrotech_LiteTop_Growing_Media_TDS.pdf '''Extensive Litetop<sup>®</sup> Growing Media'''] |
− | *'''Root Stop Tape''' | + | *[https://rpm.rcabc.org/images/7/77/Hydrotech_LiteTop_Filter_TDS.pdf '''Litetop<sup>®</sup> Filter'''] |
− | + | *[https://rpm.rcabc.org/images/2/27/Hydrotech_Gardendrain_GR10_TDS.pdf '''Gardendrain GR10'''] or [https://rpm.rcabc.org/images/d/d6/Hydrotech_Gardendrain_GR25_TDS.pdf '''Gardendrain GR25'''] | |
− | < | + | *[https://rpm.rcabc.org/images/2/2a/Hydrotech_Root_Stop_TDS.pdf '''Root Stop Standard'''] |
− | ;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | + | *[https://rpm.rcabc.org/images/1/16/Hydrotech_Root_Stop_Tape_TDS.pdf '''Root Stop Tape'''] |
+ | *[https://rpm.rcabc.org/images/0/0e/Hydrotech_GardenEdge_TDS.pdf '''GardenEdge<sup>®</sup>'''] | ||
+ | :'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor'' | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
+ | |||
+ | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 21:30, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
Hydrotech Extensive Garden Roof® Assembly
by Hydrotech Membrane Corporation
Material Acceptance and Product Details
| |
|