Difference between revisions of "Materials:SOPRANATURE Intensive-Inverted Vegetated Roof"
Difference between revisions of "Materials:SOPRANATURE Intensive-Inverted Vegetated Roof"
(4 intermediate revisions by the same user not shown) | |||
Line 7: | Line 7: | ||
<big>Group - Vegetated Roof Systems</big> | <big>Group - Vegetated Roof Systems</big> | ||
<hr> | <hr> | ||
− | <big><big><big><big><big>SOPRANATURE<sup>®</sup> Intensive-Inverted Vegetated Roof</big></big></big></big></big><br> | + | <big><big><big><big><big>SOPRANATURE<sup>®</sup> Intensive-Inverted Vegetated Roof <sup>†</sup></big></big></big></big></big><br> |
<big><big><big>by Soprema Inc.</big></big></big><br> | <big><big><big>by Soprema Inc.</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | ;System Summary: SOPRANATURE<sup>®</sup> ® Intensive Vegetated Systems by SOPREMA<sup>®</sup> correspond to heavy green roofs with more than 300 mm of SOPRAFLOR substrate. Vegetation types can include a wide variety of perennials, shrubs and trees that require frequent maintenance and heavy structural capacity. | + | ;System Summary: SOPRANATURE<sup>®</sup> ® Intensive Vegetated Systems by SOPREMA<sup>®</sup> correspond to heavy green roofs with more than 300 mm of SOPRAFLOR substrate. Vegetation types can include a wide variety of perennials, shrubs and trees that require frequent maintenance and heavy structural capacity (See the link at right to the manufacturer's online resources page for more information). |
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
+ | ;Manufacturer Online Resource: [https://www.soprema.ca/en/catalogsearch/result/?q=intensive SORPANATURE Intensive Vegetated Roof Systems] | ||
+ | ;System Type: Intensive | ||
;System Depth: 361.7 mm (12-6/16") to 361.7 mm (12-6/16") + | ;System Depth: 361.7 mm (12-6/16") to 361.7 mm (12-6/16") + | ||
;Growing Media Depth: 304.8 mm (12") to 304.8 mm (12") + | ;Growing Media Depth: 304.8 mm (12") to 304.8 mm (12") + | ||
;Vegetation Profile: Wild flower meadows, grasses, perennials, annuals, small shrubs and vegetation with medium to high water needs (as specified by the ''Design Authority''/''Green Roof Design Professional''. See '''Conditions and Limitations''' below) | ;Vegetation Profile: Wild flower meadows, grasses, perennials, annuals, small shrubs and vegetation with medium to high water needs (as specified by the ''Design Authority''/''Green Roof Design Professional''. See '''Conditions and Limitations''' below) | ||
;Suitable climate zones: All BC zones, subject to manufacturer's approval | ;Suitable climate zones: All BC zones, subject to manufacturer's approval | ||
− | ;System Components: | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | :'''Sedum Mats''' by Soprema, or non-sedum mat supplied by others* | + | :{| class="wikitable" |
− | + | |- | |
− | :'''Sopraretentio Mat''' | + | | |
− | + | *[https://rpm.rcabc.org/images/5/5f/Soprema_Sopranature_Sedum_Mat_TDS.pdf '''Sedum Mats'''] by Soprema, or non-sedum mat supplied by others* | |
− | :''' | + | *[https://rpm.rcabc.org/images/f/ff/Soprema_Sopranature_Sopraflor_X_%26_I_TDS.pdf '''Sopraflor I''' growing media] |
− | :'''Soprabarrier 30''' | + | *[https://rpm.rcabc.org/images/7/7b/Soprema_Sopranature_Sopraretentio_Mat_TDS.pdf '''Sopraretentio Mat'''] |
− | + | *[https://rpm.rcabc.org/images/d/d1/Soprema_Sopranature_Soprafiltre_TDS.pdf here] '''Soprafiltre'''] | |
− | :Sopranature<sup>®</sup> metal edging | + | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) |
− | :Sopranature<sup>®</sup> inspection chambers | + | *[https://rpm.rcabc.org/images/b/bb/Soprema_Sopranature_Soprabarrier_20_%26_30_TDS.pdf '''Soprabarrier 30'''] |
+ | *'''Soprema approved tape''' | ||
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | *[https://rpm.rcabc.org/images/f/f3/Soprema_Sopranature_Metal_Edging_TDS.pdf '''Sopranature<sup>®</sup> metal edging'''] | ||
+ | *[https://rpm.rcabc.org/images/e/e4/Soprema_Sopranature_Inspection_Chamber_TDS.pdf '''Sopranature<sup>®</sup> inspection chambers'''] | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
− | ;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | + | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. |
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> |
Latest revision as of 21:35, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
SOPRANATURE® Intensive-Inverted Vegetated Roof †
by Soprema Inc.
Material Acceptance and Product Details
| |
|