Difference between revisions of "Materials:Carlisle Semi-Intensive Roof Garden System"
Difference between revisions of "Materials:Carlisle Semi-Intensive Roof Garden System"
(8 intermediate revisions by the same user not shown) | |||
Line 17: | Line 17: | ||
| | | | ||
<div class="col-md-12"> | <div class="col-md-12"> | ||
− | <div class="col-md- | + | <div class="col-md-6"> |
;: | ;: | ||
− | ;'''Vegetated Roof System Manufacturer''': | + | ;'''Vegetated Roof System Manufacturer''': [http://www.carlislesyntec.com '''Carlisle SynTec Systems Canada'''] |
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
+ | ;System Summary: '''Carlisle Semi-Intensive Roof Garden System''', also known as a "medium" green roof, is a built-in-place system with a ''growing media'' depth ranging from 12.7 cm (5 in) to 20.3 cm (8 in). ''Semi-Intensive systems'' are typically chosen for projects requiring greater water retention and/or a more diverse plant palette. Due to the increased media depth and variety of ''vegetation'' options, these systems require a heat-welded root barrier to protect the roof membrane. These systems also tend to be heavier and demand more maintenance and watering compared to ''extensive green roofs'' (Adapted from the manufacturer's summary. See the link at right to the manufacturer's online resources page for more information) | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;System | + | ;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] |
− | ;System Depth: | + | ;System Type: Semi-Intensive |
− | ;Growing Media Depth: | + | ;System Depth: 158.8 mm (6-1/4") to 235 mm (9-1/4") |
− | ;Vegetation Profile: | + | ;Growing Media Depth: 127 mm (5") to 203.2 mm (8") |
− | ;Suitable climate zones: | + | ;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) |
− | ;System Components: | + | ;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') |
− | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) | |
− | : | + | :{| class="wikitable" |
− | : | + | |- |
− | : | + | | |
− | : | + | *[https://rpm.rcabc.org/images/d/db/Carlisle_Roof_Garden_Growth_Media_TDS.pdf '''Semi-Intensive Growth Media'''] |
+ | *[https://rpm.rcabc.org/images/9/96/Carlisle_Roof_Garden_MiraDRAIN_G4_TDS.pdf '''MiraDRAIN G4'''] | ||
+ | *[https://rpm.rcabc.org/images/1/12/Carlisle_Roof_Garden_Aluminum_Edge_TDS.pdf '''Roof Garden Aluminum Edge'''] | ||
+ | *[https://rpm.rcabc.org/images/e/ee/Carlisle_Roof_Garden_Aluminum_Drain_Box_TDS.pdf '''Roof Garden Aluminum Drain Box'''] | ||
+ | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
+ | *[https://rpm.rcabc.org/images/1/16/Carlisle_Roof_Garden_Root_Barrier_TDS.pdf '''Root Barrier'''] | ||
+ | *[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric'''] | ||
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
+ | |||
+ | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
− | |||
</div> | </div> | ||
</div> | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 21:48, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
Carlisle Semi-Intensive Roof Garden System
by Carlisle SynTec Systems Canada
System/Material Acceptance and Product Details
| |
|