;'''Vegetated Roof System Manufacturer''': Name linked to website here
+
;'''Vegetated Roof System Manufacturer''': [http://www.carlislesyntec.com '''Carlisle SynTec Systems Canada''']
 
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024
 
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024
 
;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 +
;System Summary: '''Carlisle Intensive Roof Garden System''', often referred to as a "deep" green roof, is a built-in-place system with a ''growth media'' depth starting at 20.3 cm (8 in) and beyond. These systems are typically installed over concrete roof decks due to their substantial weight. ''Intensive green roofs'' offer nearly limitless possibilities for plant selection and can be engineered to retain significant amounts of stormwater, tailored to the project's needs. Given the greater depth and diverse vegetation options, these systems require a heat-welded root barrier to protect the roof membrane, are the heaviest green roof type, and demand rigorous maintenance, often including a permanently installed irrigation system (Adapted from the manufacturer's summary. See the link at right to the manufacturer's online resources page for more information)
 
<div style="text-align: left;">
 
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg|class=img-responsive| link=https://rpm.rcabc.org/images/d/d7/Extensive_VR_System_%28sedum_tile%29.jpg]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;System Summary: description here, using <br>breaks
+
;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems]
;System Depth: give range
+
;System Type: Intensive
;Growing Media Depth: give range
+
;System Depth: min. 235 mm (9-1/4") to max. established by the design
;Vegetation Profile: give manufacturer's profile name or description
+
;Growing Media Depth: min. 203.2 mm (8") to max. established by the design
;Suitable climate zones: give range or list zone numbers
+
;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below)
;System Components:
+
;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'')
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:{| class="wikitable"
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|-
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
*[https://rpm.rcabc.org/images/d/db/Carlisle_Roof_Garden_Growth_Media_TDS.pdf '''Intensive Growth Media''']
 +
*[https://rpm.rcabc.org/images/9/96/Carlisle_Roof_Garden_MiraDRAIN_G4_TDS.pdf '''MiraDRAIN G4''']
 +
*[https://rpm.rcabc.org/images/1/12/Carlisle_Roof_Garden_Aluminum_Edge_TDS.pdf '''Roof Garden Aluminum Edge''']
 +
*[https://rpm.rcabc.org/images/e/ee/Carlisle_Roof_Garden_Aluminum_Drain_Box_TDS.pdf '''Roof Garden Aluminum Drain Box''']
 +
:'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]])
 +
*[https://rpm.rcabc.org/images/1/16/Carlisle_Roof_Garden_Root_Barrier_TDS.pdf '''Root Barrier''']
 +
*[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric''']
 +
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
 +
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
 +
 
 +
;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
 +
 
 +
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 
 +
</div>
 +
<div class="col-md-6">
 +
 
 +
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 +
 
 +
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
  
;Conditions and Limitations: description here, using <br>breaks
 
 
</div>
 
</div>
 
</div>
 
</div>
 +
<div class="col-md-12">
 +
<br>
 
|}
 
|}
  

Latest revision as of 21:49, 2 December 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


Carlisle Intensive Roof Garden System
by Carlisle SynTec Systems Canada

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
Carlisle SynTec Systems Canada
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
Carlisle Intensive Roof Garden System, often referred to as a "deep" green roof, is a built-in-place system with a growth media depth starting at 20.3 cm (8 in) and beyond. These systems are typically installed over concrete roof decks due to their substantial weight. Intensive green roofs offer nearly limitless possibilities for plant selection and can be engineered to retain significant amounts of stormwater, tailored to the project's needs. Given the greater depth and diverse vegetation options, these systems require a heat-welded root barrier to protect the roof membrane, are the heaviest green roof type, and demand rigorous maintenance, often including a permanently installed irrigation system (Adapted from the manufacturer's summary. See the link at right to the manufacturer's online resources page for more information)
Extensive VR System (banner).JPG
Manufacturer online resources
Roof Garden Systems
System Type
Intensive
System Depth
min. 235 mm (9-1/4") to max. established by the design
Growing Media Depth
min. 203.2 mm (8") to max. established by the design
Vegetation Profile
as specified by the Design Authority/Green Roof Design Professional (See Conditions and Limitations below)
Suitable climate zones
conditional on the specified vegetation profile (refer to the Design Authority/Green Roof Design Professional)
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
XPS Insulation by roofing Contractor (Refer to the RGC Standard for Vegetated Roofs)
Waterproofing Roof Assembly (membrane) by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home