− | <div class="col-md- | + | <div class="col-md-6"> |
;: | ;: | ||
;'''Vegetated Roof System Manufacturer''': [http://www.carlislesyntec.com '''Carlisle SynTec Systems Canada'''] | ;'''Vegetated Roof System Manufacturer''': [http://www.carlislesyntec.com '''Carlisle SynTec Systems Canada'''] | ||
Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
+ | ;System Summary: '''Carlisle Intensive Roof Garden System''', often referred to as a "deep" green roof, is a built-in-place system with a ''growth media'' depth starting at 20.3 cm (8 in) and beyond. These systems are typically installed over concrete roof decks due to their substantial weight. ''Intensive green roofs'' offer nearly limitless possibilities for plant selection and can be engineered to retain significant amounts of stormwater, tailored to the project's needs. Given the greater depth and diverse vegetation options, these systems require a heat-welded root barrier to protect the roof membrane, are the heaviest green roof type, and demand rigorous maintenance, often including a permanently installed irrigation system (Adapted from the manufacturer's summary. See the link at right to the manufacturer's online resources page for more information) | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ; | + | ;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] |
− | + | ;System Type: Intensive | |
− | : | ||
;System Depth: min. 235 mm (9-1/4") to max. established by the design | ;System Depth: min. 235 mm (9-1/4") to max. established by the design | ||
;Growing Media Depth: min. 203.2 mm (8") to max. established by the design | ;Growing Media Depth: min. 203.2 mm (8") to max. established by the design | ||
;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) | ;Vegetation Profile: as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) | ||
;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') | ;Suitable climate zones: conditional on the specified vegetation profile (refer to the ''Design Authority''/''Green Roof Design Professional'') | ||
− | ;System Components: | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | :'''Intensive Growth Media''' | + | :{| class="wikitable" |
− | :'''MiraDRAIN G4''' | + | |- |
− | :'''Roof Garden Aluminum Edge''' | + | | |
− | :'''Roof Garden Aluminum Drain Box''' ( | + | *[https://rpm.rcabc.org/images/d/db/Carlisle_Roof_Garden_Growth_Media_TDS.pdf '''Intensive Growth Media'''] |
− | :'''Root Barrier''' | + | *[https://rpm.rcabc.org/images/9/96/Carlisle_Roof_Garden_MiraDRAIN_G4_TDS.pdf '''MiraDRAIN G4'''] |
− | :'''300HV Protection Fabric''' ( | + | *[https://rpm.rcabc.org/images/1/12/Carlisle_Roof_Garden_Aluminum_Edge_TDS.pdf '''Roof Garden Aluminum Edge'''] |
+ | *[https://rpm.rcabc.org/images/e/ee/Carlisle_Roof_Garden_Aluminum_Drain_Box_TDS.pdf '''Roof Garden Aluminum Drain Box'''] | ||
+ | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
+ | *[https://rpm.rcabc.org/images/1/16/Carlisle_Roof_Garden_Root_Barrier_TDS.pdf '''Root Barrier'''] | ||
+ | *[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric'''] | ||
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
− | ;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | + | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. |
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 21:49, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
Carlisle Intensive Roof Garden System
by Carlisle SynTec Systems Canada
System/Material Acceptance and Product Details
| |
|