Difference between revisions of "Materials:SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof"

Jump to: navigation, search

Difference between revisions of "Materials:SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof"

 
(6 intermediate revisions by the same user not shown)
Line 23: Line 23:
 
;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
;System Summary: SKYWATER<sup>®</sup> SOPRAFLOW CONTROL Hybrid Systems by SOPREMA<sup>®</sup> are a combination of blue roof and green roof.  This assembly offers the manufacturer's best water retention capacity of the SKYWATER<sup>®</sup>systems available. Rainwater is retained both in the SOPRANATURE<sup>®</sup> vegetated roof and in the SOPRARETENTIO MODULE, which is located under the vegetated roof. This system makes it possible to reduce the volume of water as well as the flow discharged to the sewer, because of the use of the SOPRAFLOW CONTROL flow regulator..
+
;System Summary: SKYWATER<sup>®</sup> SOPRAFLOW CONTROL Hybrid Systems by SOPREMA<sup>®</sup> are a combination of blue roof and green roof.  This assembly offers the manufacturer's best water retention capacity of the SKYWATER<sup>®</sup>systems available. Rainwater is retained both in the SOPRANATURE<sup>®</sup> vegetated roof and in the SOPRARETENTIO MODULE, which is located under the vegetated roof. This system makes it possible to reduce the volume of water as well as the flow discharged to the sewer, because of the use of the SOPRAFLOW CONTROL flow regulator (See the link at right to the manufacturer's online resources page for more information).
 
<div style="text-align: left;">
 
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive  | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
 +
;Manufacturer Online Resource: [https://www.soprema.ca/en/products-systems/skywater-sopraflow-control-hybrid-roof SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof]
 +
;System Type: "Hybrid" (Blue-Green); see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs".
 
;System Depth: 136.9 mm (5-3/8") 265.2 mm (14-3/8")  
 
;System Depth: 136.9 mm (5-3/8") 265.2 mm (14-3/8")  
 
;Growing Media Depth: 76.3 mm (3") 304.8 mm (12") +  
 
;Growing Media Depth: 76.3 mm (3") 304.8 mm (12") +  
 
;Vegetation Profile: Sedums, dry prairie grasses, dry flower meadows, and vegetation with a range of water needs, inclusive of urban agricultural crops (as specified by the ''Design Authority''/''Green Roof Design Professional''.  See '''Conditions and Limitations'''.  Suitable vegetation depends on the selection of growing media).
 
;Vegetation Profile: Sedums, dry prairie grasses, dry flower meadows, and vegetation with a range of water needs, inclusive of urban agricultural crops (as specified by the ''Design Authority''/''Green Roof Design Professional''.  See '''Conditions and Limitations'''.  Suitable vegetation depends on the selection of growing media).
 
;Suitable climate zones: All BC zones, subject to manufacturer's approval
 
;Suitable climate zones: All BC zones, subject to manufacturer's approval
;System Components:
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
:'''Sedum Mats''' by Soprema, or non-sedum mat supplied by others* (Click [https://rpm.rcabc.org/images/5/5f/Soprema_Sopranature_Sedum_Mat_TDS.pdf here] for the Technical Data Sheet PDF)
+
:{| class="wikitable"
:'''Sopraflor X'', '''I''', or '''AU''' growing media (Click [link here] for the Technical Data Sheet PDF)
+
|-
:'''Sopraretentio Mat''' (Click [link here] for the Technical Data Sheet PDF)
+
|
:'''Soprafiltre''' (Click [link here] for the Technical Data Sheet PDF)
+
*[https://rpm.rcabc.org/images/5/5f/Soprema_Sopranature_Sedum_Mat_TDS.pdf '''Sedum Mats''']
:'''Sopraretentio Module''' (Click [link here] for the Technical Data Sheet PDF)
+
*Sopraflor Growing Media:
:'''Sopradrain Eco-5''' (Click [link here] for the Technical Data Sheet PDF)
+
**[https://rpm.rcabc.org/images/f/ff/Soprema_Sopranature_Sopraflor_X_%26_I_TDS.pdf '''Sopraflor X and I''']
:'''Soprabarrier 30''' (Click [link here] for the Technical Data Sheet PDF)
+
**[https://rpm.rcabc.org/images/8/89/Soprema_Sopranature_Sopraflor_AU_TDS.pdf '''Sopraflor AU''']
:Soprema approved tape
+
*[https://rpm.rcabc.org/images/7/7b/Soprema_Sopranature_Sopraretentio_Mat_TDS.pdf '''Sopraretentio Mat''']
:Sopranature<sup>®</sup> metal edging
+
*[https://rpm.rcabc.org/images/d/d1/Soprema_Sopranature_Soprafiltre_TDS.pdf '''Soprafiltre''']
:Sopranature<sup>®</sup> inspection chambers
+
*[https://rpm.rcabc.org/images/e/e1/Soprema_Sopranature_Sopraretentio_Module_TDS.pdf  '''Sopraretentio Module''']
 +
*[https://rpm.rcabc.org/images/7/7e/Soprema_Sopranature_Sopradrain_ECO-5_TDS.pdf '''Sopradrain Eco-5''']
 +
:'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]])
 +
*[https://rpm.rcabc.org/images/b/bb/Soprema_Sopranature_Soprabarrier_20_%26_30_TDS.pdf '''Soprabarrier 30''']
 +
*[https://rpm.rcabc.org/images/d/da/Soprema_Sopranature_Sopraflow_Control_TDS.pdf '''Sopraflow Control''']
 +
:'''Soprema approved tape'''
 +
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
 +
*[https://rpm.rcabc.org/images/f/f3/Soprema_Sopranature_Metal_Edging_TDS.pdf '''Sopranature<sup>®</sup> metal edging''']
 +
*[https://rpm.rcabc.org/images/e/e4/Soprema_Sopranature_Inspection_Chamber_TDS.pdf '''Sopranature<sup>®</sup> inspection chambers''']
 +
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
  
::<sup>*</sup>See Conditions and Limitations
+
;<sup></sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
  
;Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
+
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 
 +
</div>
 +
<div class="col-md-6">
 +
 
 +
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 +
 
</div>
 
</div>
 
</div>
 
</div>

Latest revision as of 23:21, 2 December 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


SKYWATER® SOPRAFLOW CONTROL-Conventional Hybrid Roof
by Soprema Inc.

Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
Soprema Inc.
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
SKYWATER® SOPRAFLOW CONTROL Hybrid Systems by SOPREMA® are a combination of blue roof and green roof. This assembly offers the manufacturer's best water retention capacity of the SKYWATER®systems available. Rainwater is retained both in the SOPRANATURE® vegetated roof and in the SOPRARETENTIO MODULE, which is located under the vegetated roof. This system makes it possible to reduce the volume of water as well as the flow discharged to the sewer, because of the use of the SOPRAFLOW CONTROL flow regulator (See the link at right to the manufacturer's online resources page for more information).
Extensive VR System (banner).JPG
Manufacturer Online Resource
SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof
System Type
"Hybrid" (Blue-Green); see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
System Depth
136.9 mm (5-3/8") 265.2 mm (14-3/8")
Growing Media Depth
76.3 mm (3") 304.8 mm (12") +
Vegetation Profile
Sedums, dry prairie grasses, dry flower meadows, and vegetation with a range of water needs, inclusive of urban agricultural crops (as specified by the Design Authority/Green Roof Design Professional. See Conditions and Limitations. Suitable vegetation depends on the selection of growing media).
Suitable climate zones
All BC zones, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
XPS Insulation by roofing Contractor (Refer to the RGC Standard for Vegetated Roofs)
Soprema approved tape
Waterproofing Roof Assembly (membrane) by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home