Difference between revisions of "PVC Plumbing Vent (Conventional Roof System)"
Difference between revisions of "PVC Plumbing Vent (Conventional Roof System)"
(Created page with "{{Template:RPM Info}} {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} __NOTOC__ <big>...") |
|||
| Line 1: | Line 1: | ||
| − | + | ||
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
| Line 8: | Line 8: | ||
<big><big><big><big><big>PVC | Plumbing Vent (Conventional Roof System)</big></big></big></big></big> | <big><big><big><big><big>PVC | Plumbing Vent (Conventional Roof System)</big></big></big></big></big> | ||
{{Template:Construction Details Header}} | {{Template:Construction Details Header}} | ||
| − | <div class="panel panel- | + | <div class="panel panel-success"> |
<div class="panel-heading"><big>'''PVC Details'''</big></div> | <div class="panel-heading"><big>'''PVC Details'''</big></div> | ||
<div class="panel-body"> | <div class="panel-body"> | ||
| Line 14: | Line 14: | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
<br> | <br> | ||
| − | [[File: | + | [[File:Part 12 - CD - Plumbing Vent - PVC.png |class=img-responsive | link=https://rpm.rcabc.org/images/9/94/Part_12_-_CD_-_Plumbing_Vent_-_PVC.png]] |
:Drawing NTS | :Drawing NTS | ||
</div> | </div> | ||
| Line 21: | Line 21: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
| + | ;(1) [[PVC Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If specified and included in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly. | ||
| + | ;(2) [[PVC Roof Systems Standard#PART_6|'''Air or Vapour Control Layer''']]: As required by ''Design Authority''. | ||
| + | ;(3) [[PVC Roof Systems Standard#PART_6|'''Air or Vapour Control Layer Tie-in''']]: Illustrated to show AVB continuity with penetration. | ||
| + | ;(4) [[PVC Roof Systems Standard#PART_7|'''Insulation''']]: Multiple layering shown (Refer to '''Part 7''' for design, material, and installation requirements). | ||
| + | ;(5) [[PVC Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required by the RGC Standard; see '''Part 8''' for design, material, and installation requirements. Additionally, an overlay is required is included in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly. | ||
| + | ;(6) [[PVC Roof Systems Standard#PART_9|'''Field Sheet Membrane''']]: Selected to conform to the requirements in [https://rpm.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#9.2.1.1. Membrane Composition, Thickness, and Selection '''Table 9.2.1.1.'''] and conforming to the options or requirements in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly. | ||
| + | ;(7) [[PVC Roof Systems Standard#PART_12 | '''Wood Blocking''']]: Required for sheet membrane securement around penetration. | ||
| + | ;(8) [[PVC Roof Systems Standard#PART_12 | '''Penetration Flashing''']]: Purpose-made plumbing vent flashing fabricated and supplied by the membrane ''manufacturer''. Adhere to field membrane with proprietary sealant. | ||
| + | ;(9) [[PVC Roof Systems Standard#PART_12 | '''Edge Sealant''']]: Proprietary (membrane manufacturer) and applied to edge of membrane. | ||
| + | ;(10) [[PVC Roof Systems Standard#PART_12 | '''Sealant''']]: Proprietary (membrane manufacturer) and applied to edge of boot flashing. | ||
| + | ;(11) [[PVC Roof Systems Standard#PART_12 | '''Mechanical Band Clamp''']]:Required by the RGC Standard. | ||
| − | + | <hr> | |
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
| − | ; | + | ;(A) [[PVC Roof Systems Standard#PART_2|'''Supporting (Structural) Roof Deck''']]: Steel deck illustrated. |
| + | ;(B) '''Plumbing Penetration''': Extend to match top of metal flashing. | ||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
Revision as of 22:15, 6 November 2025
Division D - Construction Details
PVC | Plumbing Vent (Conventional Roof System)
| Notice to Reader | |
| Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. | |
PVC Details
1 WORK INCLUDED
- (1) Supporting Deck Overlay
- If specified and included in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
- (2) Air or Vapour Control Layer
- As required by Design Authority.
- (3) Air or Vapour Control Layer Tie-in
- Illustrated to show AVB continuity with penetration.
- (4) Insulation
- Multiple layering shown (Refer to Part 7 for design, material, and installation requirements).
- (5) Insulation Overlay
- As required by the RGC Standard; see Part 8 for design, material, and installation requirements. Additionally, an overlay is required is included in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
- (6) Field Sheet Membrane
- Selected to conform to the requirements in Membrane Composition, Thickness, and Selection Table 9.2.1.1. and conforming to the options or requirements in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
- (7) Wood Blocking
- Required for sheet membrane securement around penetration.
- (8) Penetration Flashing
- Purpose-made plumbing vent flashing fabricated and supplied by the membrane manufacturer. Adhere to field membrane with proprietary sealant.
- (9) Edge Sealant
- Proprietary (membrane manufacturer) and applied to edge of membrane.
- (10) Sealant
- Proprietary (membrane manufacturer) and applied to edge of boot flashing.
- (11) Mechanical Band Clamp
- Required by the RGC Standard.
2 RELATED WORK BY OTHERS
- (A) Supporting (Structural) Roof Deck
- Steel deck illustrated.
- (B) Plumbing Penetration
- Extend to match top of metal flashing.
NOTE: See the PVC Roof Systems Standard for additional requirements.