(WORK INCLUDED)
(WORK INCLUDED)
Line 13: Line 13:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''5. Primary Membrane and Membrane Protection''']]:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''5. Primary Membrane and Membrane Protection''']]:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''6. Membrane Flashing''']]:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''6. Membrane Flashing''']]:
:Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. See '''Perimeter Flashings: Membrane''' for RoofStar Guarantee Standards.
+
:Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge.
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#METALBASE-SBS|'''7. Metal Base Flashing''']]:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#METALBASE-SBS|'''7. Metal Base Flashing''']]:
 
:Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
 
:Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''8. Metal Cap Flashing''']]:
 
;[[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''8. Metal Cap Flashing''']]:
:Flashings 1 and 2 may be one piece.  Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. See '''Perimeter Metal Flashings''' for requirements.
+
:Flashings 1 and 2 may be one piece.  Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams.
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===

Revision as of 22:08, 18 July 2016

10.3.1.1.jpg

1 WORK INCLUDED

1. Gypsum Board
If required by design authority.
2. Vapour Retarder
If required by design authority.
3. Insulation
See list of Accepted Materials.
4. Insulation Overlay Board
As required.
5. Primary Membrane and Membrane Protection
6. Membrane Flashing
Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge.
7. Metal Base Flashing
Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
8. Metal Cap Flashing
Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

(B) Air / Vapour Seal

(C) Acceptable Wall Surface

(D) Wood Blocking

(E) Sloped Wood Blocking: Required over 100 mm (4") parapet width. See RGC Guarantee Standard A6.9

NOTE: Refer to RGC Guarantee Standards for additional requirements.]