Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"

Jump to: navigation, search

Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"

(Created page with "File:10.3.5.5.jpg === WORK INCLUDED === (1) <b>Gypsum Overlay Board: </b>If required by design authority. (2) <b>Vapour Retarder:</b> If required by design authority....")
 
(RELATED WORK BY OTHERS)
Line 37: Line 37:
 
*Aluminum flashings required for torch-applied roof systems.
 
*Aluminum flashings required for torch-applied roof systems.
  
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
+
:'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
  
  

Revision as of 16:11, 19 July 2016

10.3.5.5.jpg

1 WORK INCLUDED

(1) Gypsum Overlay Board: If required by design authority.

(2) Vapour Retarder: If required by design authority.

(3) Insulation: See list of accepted materials in Section 2.2.

(4) Insulation Overlay: As required. See RGC Guarantee Standard B4.1, B4.2 and C4.1

(5) Primary Membrane and Membrane Protection

(6) Mastic: As approved by manufacturer.

(7) Membrane Flashing: Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems.

(8) Storm Collar, Typical Lead Cap or Typical Aluminum Cap: Reroofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashings.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

(B) Plumbing Stack: Extend to match top of metal flashing.

(C) Wood Blocking: Optional.

(D) Metal Flashing: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.

(E) Typical Aluminum Cap: For use with aluminum flashings.

(F) Typical Lead Cap: For use with lead flashings.

(G) Storm Collar: Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings.

NOTE
  • Refer to RGC Guarantee Standards for additional requirements
  • Aluminum flashings required for torch-applied roof systems.
NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details