Difference between revisions of "ASM Valley (Unhooked)"

Jump to: navigation, search

Difference between revisions of "ASM Valley (Unhooked)"

(RELATED WORK BY OTHERS)
Line 26: Line 26:
 
(A) <b>Acceptable Deck</b>  
 
(A) <b>Acceptable Deck</b>  
  
NOTE: * Refer to <i>RGC Guarantee Standards</i> for additional requirements.  
+
 
 +
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 +
 
  
 
<hr>
 
<hr>

Revision as of 18:54, 19 July 2016


8.1.4.6.1.jpg


1 WORK INCLUDED

(1) Valley Protection Membrane: Accepted self-adhered modified bituminous eave protection membrane.

(2) Underlayment: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).

(3) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.

(4) Valley Metal Panel: Preformed with centre rib.

(5) Metal Clip: Installed to metal roof panel manufacturer’s printed instructions.

(6) Pre-Formed Closures: Two rows set in accepted caulking.

(7) Architectural Metal Roof Panel

(8) Valley Panel Overlap: Overlaps minimum 200 mm (8") sealed with two rows of accepted caulking and drag load fasteners.


2 RELATED WORK BY OTHERS

(A) Acceptable Deck


NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to ASM Application

Back to ASM Construction Details

Back to Construction Details