Difference between revisions of "SBS Roof System Details"

Jump to: navigation, search

Difference between revisions of "SBS Roof System Details"

Line 47: Line 47:
 
:[[SBS Details:D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)|D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)]]
 
:[[SBS Details:D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)|D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)]]
  
 +
<hr>
  
<hr>
 
  
  
  
[[SBS Roof Systems|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''SBS Roof Systems'']]
+
[[SBS Roof Systems|<i class="fa fa-chevron-circle-left" ></i> Back to ''SBS Roof Systems'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details Section'']]
+
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left" ></i> Back to ''Construction Details Section'']]

Revision as of 20:44, 27 July 2016

The drawings contained within this section are intended to represent a variety of modified bituminous roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult manufacturers’ specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and RGC.

For further information about SBS membrane system design and requirements, see SBS Roof Systems.


D1.7.1 Assemblies (Insulated Conventional)
D1.7.2 Assemblies (Protected Membrane)
D1.7.3 Parapets & Copings (Low Parapet - Wall Supported)
D1.7.4 Parapets & Copings (Low Parapet - Unsupported by Wall)
D1.7.5 Parapets & Copings (High Parapet - Wall Supported)
D1.7.6 Parapets & Copings (Parapet - Wall Transition)
D1.7.7 Edges & Fascia (Cant Edge)
D1.7.8 Edges & Fascia (Gravel Stop)
D1.7.9 Counter-flashings & Reglets (Deck - Wall Supported)
D1.7.10 Counter-flashings & Reglets (Deck - Unsupported by Wall)
D1.7.11 Counter-flashings & Reglets (Stucco Wall: Re-roofing)
D1.7.13 Counter-flashings & Reglets (Double Surface Reglet)
D1.7.14 Counter-flashings & Reglets (Low Door Sill)
D1.7.15 Counter-flashings & Reglets (Window Curb)
D1.7.16 Roof-Wall Transitions (Expansion Joint)
D1.7.17 Roof-Wall Transitions (Divider/Control Joint)
D1.7.18 Roof-Wall Transitions (Fire Separation Joint)
D1.7.19 Roof-Wall Transitions (Fire Separation Wall)
D1.7.20 Curbs & Sleepers (Equipment Sleeper)
D1.7.21 Curbs & Sleepers (Multiple Roof Penetrations)
D1.7.22 Curbs & Sleepers (Basic Curb)
D1.7.23 Curbs & Sleepers (Mechanical Opening)
D1.7.24 Curbs & Sleepers (Pre-curb for Planters)
D1.7.25 Strip-in Flashings (Metal Plumbing)
D1.7.26 Strip-in Flashings (Two-part Cable)
D1.7.27 Strip-in Flashings (Gum Pan/Pitch Pocket)
D1.7.28 Water & Drainage (Cast Iron Drain)
D1.7.29 Water & Drainage (Spun Copper Drain)
D1.7.30 Water & Drainage (Clamping Spun Copper Drain)
D1.7.31 Water & Drainage (Open Wall Scupper)
D1.7.32 Water & Drainage (Through-wall Scupper)
D1.7.33 Miscellaneous Penetrations (Roof Anchor)
D1.7.34 Miscellaneous Penetrations (Wall Anchor - Conventional Roof Assy)
D1.7.35 Miscellaneous Penetrations (Wall Anchor - Protected Roof Assy)
D1.7.36 Miscellaneous Penetrations (Guardrails)

NOTE: The following pages are currently under construction
D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)



Back to SBS Roof Systems

Back to Construction Details Section