Difference between revisions of "SBS Canted Edge"
Difference between revisions of "SBS Canted Edge"
(→RELATED WORK BY OTHERS) |
|||
Line 6: | Line 6: | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) | + | ;(1) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSVAPOUR|'''Vapour Retarder''']]: If required by design authority. |
− | :If required by design authority. | + | ;(2) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''Insulation''']]: Mechanically fastened where deck type permits. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. |
− | ;(2) Insulation | + | ;(3) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATIONOVERLAY|'''Insulation Overlay Board''']]: Asphalt adhered or mechanically fastened. Two layers required over heat-sensitive insulation. |
− | :Mechanically fastened where deck type permits. | + | ;(4) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Base Sheet''']]: Adhered to overlay board using asphalt, cold adhesive, self-adhered, mechanical attachment or torch applied according to manufacturer's specification. Torching directly to wood surfaces is not permitted. |
− | ;(3) Overlay Board | + | ;(5) [[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Base Sheet Flashing''']]: Adhered according to manufacturer's specifications, using cold adhesive, hot asphalt self-adhered or torch applied to cover boards, or mechanically attached membrane. Must be carried over to outside of fascia. Torching directly to wood surfaces is not permitted. See also [[RoofStar Guarantee Standards for SBS Roof Systems#SBSCANT|'''10.3.6 Cant Strips''']]. |
− | :Asphalt adhered or mechanically fastened. Two layers required over heat-sensitive insulation. | + | ;(6) [[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Cap Sheet''']]: Applied according to manufacturer's printed instructions and <i>RoofStar Guarantee Standards</i>. |
− | ;(4) | + | ;(7) [[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Cap Sheet Flashing''']]: Applied according to manufacturer's printed instructions and <i>RoofStar Guarantee Standards</i> up to the top of cant. |
− | :Adhered to overlay board using asphalt, cold adhesive, self-adhered, mechanical attachment or torch applied according to manufacturer | + | ;(8) [[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''Metal Flashing''']]: As required by <i>RoofStar Guarantee Standards</i>. |
− | ;(5) | ||
− | :Adhered according to manufacturer | ||
− | ;(6) | ||
− | :Applied according to manufacturer | ||
− | ;(7) | ||
− | :Applied according to manufacturer | ||
− | ;(8) | ||
− | :As required by <i> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) | + | ;(A) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSDECKS|'''Acceptable Deck''']]: Smooth, dry and clean. |
− | :Smooth, dry and clean. | + | ;(B) '''Fascia''': Optional. |
− | ;(B) | + | ;(C) '''Wood Blocking''': Equal to height of insulation and overlay board, primed wherever in contact with asphalt. |
− | :Optional. | ||
− | ;(C) | ||
− | :Equal to height of insulation and overlay board, primed wherever in contact with asphalt. | ||
Revision as of 22:20, 29 July 2016
1 WORK INCLUDED
- (1) Vapour Retarder
- If required by design authority.
- (2) Insulation
- Mechanically fastened where deck type permits. See available insulation products in the Accepted Materials section of this Manual.
- (3) Insulation Overlay Board
- Asphalt adhered or mechanically fastened. Two layers required over heat-sensitive insulation.
- (4) Base Sheet
- Adhered to overlay board using asphalt, cold adhesive, self-adhered, mechanical attachment or torch applied according to manufacturer's specification. Torching directly to wood surfaces is not permitted.
- (5) Base Sheet Flashing
- Adhered according to manufacturer's specifications, using cold adhesive, hot asphalt self-adhered or torch applied to cover boards, or mechanically attached membrane. Must be carried over to outside of fascia. Torching directly to wood surfaces is not permitted. See also 10.3.6 Cant Strips.
- (6) Cap Sheet
- Applied according to manufacturer's printed instructions and RoofStar Guarantee Standards.
- (7) Cap Sheet Flashing
- Applied according to manufacturer's printed instructions and RoofStar Guarantee Standards up to the top of cant.
- (8) Metal Flashing
- As required by RoofStar Guarantee Standards.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- Smooth, dry and clean.
- (B) Fascia
- Optional.
- (C) Wood Blocking
- Equal to height of insulation and overlay board, primed wherever in contact with asphalt.