Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"
Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"
(→RELATED WORK BY OTHERS) |
|||
Line 2: | Line 2: | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | (1) | + | ;(1) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSSUBSTRATES|'''Gypsum Deck Overlay''']]: If required by design authority. |
+ | ;(2) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSVAPOUR|'''Vapour Retarder''']]: If required by design authority. | ||
+ | ;(3) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. | ||
+ | ;(4) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATIONOVERLAY|'''Insulation Overlay Board''']]: | ||
+ | ;(5) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Primary Membrane and Membrane Protection''']] | ||
+ | ;(6) '''Mastic''': As approved by manufacturer. | ||
+ | ;(7) [[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Membrane Flashing''']]: Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems. | ||
+ | ;(8) '''Storm Collar, Typical Lead Cap or Typical Aluminum Cap''': Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing. | ||
− | + | <hr> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | (A) | + | ;(A) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSDECKS|'''Acceptable Deck''']] |
− | + | ;(B) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSSETTLEMENT|'''Plumbing Stack''']]: Extend to match top of metal flashing. | |
− | (B) | + | ;(C) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSWOODBLOCKING|'''Wood Blocking''']]: Optional. |
− | + | ;(D) [[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck. | |
− | (C) | + | ;(E) '''Typical Aluminum Cap''': For use with aluminum flashing. See requirements for [[RoofStar Guarantee Standards for SBS Roof Systems#SBSSETTLEMENT|'''Settlement Caps''']] on strip-in plumbing flashings. |
− | + | ;(F) '''Typical Lead Cap''': For use with lead flashing. | |
− | (D) | + | ;(G) '''Storm Collar''': Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings. |
− | |||
− | (E) | ||
− | |||
− | (F) | ||
− | |||
− | (G) | ||
Revision as of 18:43, 5 August 2016
1 WORK INCLUDED
- (1) Gypsum Deck Overlay
- If required by design authority.
- (2) Vapour Retarder
- If required by design authority.
- (3) Insulation
- Mechanically fastened. See available insulation products in the Accepted Materials section of this Manual.
- (4) Insulation Overlay Board
- (5) Primary Membrane and Membrane Protection
- (6) Mastic
- As approved by manufacturer.
- (7) Membrane Flashing
- Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems.
- (8) Storm Collar, Typical Lead Cap or Typical Aluminum Cap
- Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Plumbing Stack
- Extend to match top of metal flashing.
- (C) Wood Blocking
- Optional.
- (D) Metal Flashing
- Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
- (E) Typical Aluminum Cap
- For use with aluminum flashing. See requirements for Settlement Caps on strip-in plumbing flashings.
- (F) Typical Lead Cap
- For use with lead flashing.
- (G) Storm Collar
- Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings.
- NOTE
- Refer to RGC Guarantee Standards for additional requirements
- Aluminum flashings required for torch-applied roof systems.