=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
(1) <b>Inverted Roof Assembly</b>
+
;(1) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSPMRA|'''Inverted (Protected) Roof Assembly''']]
 +
;(2) [[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''Counter-flashing''']]
 +
;(3) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''Insulation - XPS''']]: See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
 +
;(4) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Primary Membrane''']]
  
(2) <b>Metal Counter Flashing</b>
+
<hr>
 
 
(3) <b>Insulation:</b> Extruded Polystyrene
 
 
 
(4) <b>Primary Membrane</b>
 
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
(A) <b>Acceptable Deck</b>
+
;(A) [[RoofStar Guarantee Standards for SBS Roof Systems#SBSDECKS|'''Acceptable Deck''']]
 
+
;(B) '''Anchor''': to CSA Z91-M90 - Poured concrete shown, see anchor manufacturer's attachment for other wall types and attachment methods.
(B) <b>Anchor</b> to CSA Z91-M90: Poured concrete shown, see anchor manufacturer&#8217;s attachment for other wall types and attachment methods
+
;(C) '''Anchor Eye''': to CSA Z91-M90
 
+
;(D) '''Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants''': Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished  roof surfacing.
(C) <b>Anchor Eye</b> to CSA Z91-M90
+
;(E) '''Plywood''': 15.9 mm (5/8") treated where required.
 
 
(D) <b>Anchor Placement</b> For Roof Decks Accessible By General Public/Residential Occupants: Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished  roof surfacing.
 
 
 
(E) <b>Plywood:</b> 15.9 mm (5/8") treated where required.
 
  
  
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
+
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
  

Revision as of 21:44, 5 August 2016

10.3.7.3.jpg

1 WORK INCLUDED

(1) Inverted (Protected) Roof Assembly
(2) Counter-flashing
(3) Insulation - XPS
See available insulation products in the Accepted Materials section of this Manual.
(4) Primary Membrane

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Anchor
to CSA Z91-M90 - Poured concrete shown, see anchor manufacturer's attachment for other wall types and attachment methods.
(C) Anchor Eye
to CSA Z91-M90
(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants
Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.
(E) Plywood
15.9 mm (5/8") treated where required.


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details