Difference between revisions of "TPO Conventionally Insulated System (Alternate)"

Jump to: navigation, search

Difference between revisions of "TPO Conventionally Insulated System (Alternate)"

(WORK INCLUDED)
Line 9: Line 9:
 
;(5) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOLAP|'''Membrane Lap''']]: Thermoplastic membrane may be welded or chemically bonded.
 
;(5) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOLAP|'''Membrane Lap''']]: Thermoplastic membrane may be welded or chemically bonded.
 
;(6) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOEDGE|'''Edge Flashing''']]: Proprietary, coated with membrane material and heat-welded to the primary (field) membrane.
 
;(6) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOEDGE|'''Edge Flashing''']]: Proprietary, coated with membrane material and heat-welded to the primary (field) membrane.
;(7) '''Fascia Flashing Clip''': Affixed to the fascia material (installed by others) with fasteners O.C. 300 mm (12”)
+
;(7) '''Fascia Flashing Clip''': Affixed to the fascia material (installed by others) with fasteners O.C. 300 mm (12”).
 
;(8) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOFASCIA|'''Fascia Flashing''']]: Manufactured to RoofStar Guarantee Standards for sheet metal flashings.
 
;(8) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOFASCIA|'''Fascia Flashing''']]: Manufactured to RoofStar Guarantee Standards for sheet metal flashings.
 
;(9) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOSTRIPPING|'''Membrane Flashing''']]: Adhered according to manufacturer’s printed specifications using proprietary adhesive.  Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface.  Welded or adhered to primary membrane depending on membrane type.
 
;(9) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOSTRIPPING|'''Membrane Flashing''']]: Adhered according to manufacturer’s printed specifications using proprietary adhesive.  Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface.  Welded or adhered to primary membrane depending on membrane type.

Revision as of 22:25, 8 August 2016

6.3.2.1.jpg


1 WORK INCLUDED

(1) Vapour Retarder
If required by design authority.
(2) Insulation
Mechanically fastened where deck type permits, or fully adhered (as illustrated). Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
(3) Adhesive
Proprietary, installed according to manufacturer’s instructions, usually brushed, rolled or sprayed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)
(4) Single-ply Membrane
Installed according to manufacturer’s instructions and RoofStar Guarantee Standards.
(5) Membrane Lap
Thermoplastic membrane may be welded or chemically bonded.
(6) Edge Flashing
Proprietary, coated with membrane material and heat-welded to the primary (field) membrane.
(7) Fascia Flashing Clip
Affixed to the fascia material (installed by others) with fasteners O.C. 300 mm (12”).
(8) Fascia Flashing
Manufactured to RoofStar Guarantee Standards for sheet metal flashings.
(9) Membrane Flashing
Adhered according to manufacturer’s printed specifications using proprietary adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhered to primary membrane depending on membrane type.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Acceptable Parapet Surface
Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer.
(C) Edge Blocking

(D) Fascia Material


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.





Back to TPO/PVC Application

Back to TPO/PVC Construction Details

Back to Construction Details